Absorbed dose model to scan parameters in dental cone beam computed tomography

被引:0
作者
Jia, Shumei [1 ]
Guo, Xiaoyue [1 ]
Xing, Yuxiang [1 ]
Zhang, Li [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
来源
2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2019年
关键词
CT;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cone beam computed tomography (CBCT) is widely applied in dental and maxillofacial diagnostic imaging, which raises great concerns to radiological dose caused by this device. This work measures the absorbed dose inside an uniform cylindrical phantom when it is scanned by dental CBCT at different scan parameters of mAs and kV; meanwhile, studies the relationship of absorbed dose to scan parameters. The result indicates that absorbed dose is correlated to scan parameters in an empirical model form of D = (a center dot HVL2 + b) center dot mAs with coefficient of determination above 0.99. This empirical model can be applied to other type dental CBCT devices to provide as an estimation method of radiology dose at different scan parameter settings. Moreover, absorbed dose is proportional to field of view size and inversely proportional to phantom size.
引用
收藏
页数:4
相关论文
共 50 条
[21]   Image retake rates of cone beam computed tomography in a dental institution [J].
Hung, Kuofeng ;
Hui, Liuling ;
Yeung, Andy Wai Kan ;
Scarfe, William C. ;
Bornstein, Michael M. .
CLINICAL ORAL INVESTIGATIONS, 2020, 24 (12) :4501-4510
[22]   Effects of Exposure Parameters and Voxel Size for Cone-Beam Computed Tomography on the Image Matching Accuracy with an Optical Dental Scan Image: An In Vitro Study [J].
Mai, Hang-Nga ;
Lee, Du-Hyeong .
BIOMED RESEARCH INTERNATIONAL, 2021, 2021
[23]   Significant reduction in dental cone beam computed tomography (CBCT) eye dose through the use of leaded glasses [J].
Prins, R. ;
Dauer, L. T. ;
Colosi, D. C. ;
Quinn, B. ;
Kleiman, N. J. ;
Bohle, G. C. ;
Holohan, B. ;
Al-Najjar, A. ;
Fernandez, T. ;
Bonvento, M. ;
Faber, R. D. ;
Ching, H. ;
Goren, A. D. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 112 (04) :502-507
[24]   Ionizing radiation and its considerations in imaging diagnosis: comparison of absorbed dose between cone beam computed tomography and multi-detector computed tomography in the head and neck [J].
Oliveira, P. L. E. ;
Starling, C. R. ;
Mauricio, C. L. P. ;
Guedes, F. R. ;
Visconti, M. A. ;
Ruellas, A. C. O. .
RADIOPROTECTION, 2021, 56 (02) :111-115
[25]   Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand [J].
Neubauer, J. ;
Neubauer, C. ;
Gerstmair, A. ;
Krauss, T. ;
Reising, K. ;
Zajonc, H. ;
Kotter, E. ;
Langer, M. ;
Fiebich, M. ;
Voigt, J. .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05) :488-493
[26]   EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY [J].
Mettivier, Giovanni ;
Costa, Matilde ;
Lanconelli, Nico ;
Ianiro, Anna ;
Pugliese, Mariagabriella ;
Quarto, Maria ;
Russo, Paolo .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) :473-481
[27]   Dose delivered to the patient by megavoltage cone beam computed tomography imaging [J].
Isambert, A. ;
Ferreira, I. H. ;
Bossi, A. ;
Beaudre, A. ;
Nicula, L. E. ;
Lefkopoulos, D. .
CANCER RADIOTHERAPIE, 2009, 13 (05) :358-364
[28]   EVALUATION OF THYROID RADIATION DOSE USING CONE BEAM COMPUTED TOMOGRAPHY [J].
Penteado Setti da Rocha, Anna Silvia ;
Aguiar, Guilherme de Mello ;
Tulio, Ana Paula ;
Ditzel, Alessandra S. ;
Filipov, Danielle .
RADIATION PROTECTION DOSIMETRY, 2017, 175 (03) :368-372
[29]   Imaging dose from cone beam computed tomography in radiation therapy [J].
Alaei, Parham ;
Spezi, Emiliano .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07) :647-658
[30]   Effective dose estimates for cone beam computed tomography in interventional radiology [J].
Kwok, Y. M. ;
Irani, F. G. ;
Tay, K. H. ;
Yang, C. C. ;
Padre, C. G. ;
Tan, B. S. .
EUROPEAN RADIOLOGY, 2013, 23 (11) :3197-3204