Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit

被引:773
作者
Zhong, Qing-Chang [1 ]
Phi-Long Nguyen [2 ]
Ma, Zhenyu [2 ]
Sheng, Wanxing [3 ]
机构
[1] Univ Sheffield, Dept Automat Control & Syst Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Univ Loughborough, Dept Aeronaut & Automot Engn, Loughborough LE11 3TU, Leics, England
[3] China Elect Power Res Inst, Dept Power Distribut, Beijing 100192, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
Droop control; grid connection; microgrid; PLL; renewable energy; smart grid integration; synchronization; synchronverters; virtual synchronous machines; PHASE-LOCKED LOOP; GRID SYNCHRONIZATION; PLL; CONVERTERS; FILTER; SYSTEM;
D O I
10.1109/TPEL.2013.2258684
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A synchronverter is an inverter that mimics synchronous generators, which offers a mechanism for power systems to control grid-connected renewable energy and facilitates smart grid integration. Similar to other grid-connected inverters, it needs a dedicated synchronization unit, e. g., a phase-locked loop (PLL), to provide the phase, frequency, and amplitude of the grid voltage as references. In this paper, a radical step is taken to improve the synchronverter as a self-synchronized synchronverter by removing the dedicated synchronization unit. It can automatically synchronize itself with the grid before connection and track the grid frequency after connection. This considerably improves the performance, reduces the complexity, and computational burden of the controller. All the functions of the original synchronverter, such as frequency and voltage regulation, real power, and reactive power control, are maintained. Both simulation and experimental results are presented to validate the control strategy. Experimental results have shown that the proposed control strategy can improve the performance of frequency tracking by more than 65%, the performance of real power control by 83%, and the performance of reactive power control by about 70%.
引用
收藏
页码:617 / 630
页数:14
相关论文
共 29 条
[1]  
[Anonymous], 2009, P 2009 IEEE PES POW, DOI DOI 10.1109/PSCE.2009.4840013
[2]   Overview of control and grid synchronization for distributed power generation systems [J].
Blaabjerg, Frede ;
Teodorescu, Remus ;
Liserre, Marco ;
Timbus, Adrian V. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) :1398-1409
[3]   A new single-phase PLL structure based on second order generalized integrator [J].
Ciobotaru, Mihai ;
Teodorescu, Remus ;
Blaabjerg, Frede .
2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, :361-+
[4]   A Digital PLL Scheme for Three-Phase System Using Modified Synchronous Reference Frame [J].
da Silva, Carlos Henrique ;
Pereira, Rondineli Rodrigues ;
Borges da Silva, Luiz Eduardo ;
Lambert-Torres, Germano ;
Bose, Bimal K. ;
Ahn, Se Un .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (11) :3814-3821
[5]  
Dong D, 2011, APPL POWER ELECT CO, P1622, DOI 10.1109/APEC.2011.5744812
[6]   Fixed-Reference-Frame Phase-Locked Loop for Grid Synchronization Under Unbalanced Operation [J].
Escobar, Gerardo ;
Martinez-Montejano, Misael F. ;
Valdez, Andres A. ;
Martinez, Panfilo R. ;
Hernandez-Gomez, Michael .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (05) :1943-1951
[7]   Multiple-Complex Coefficient-Filter-Based Phase-Locked Loop and Synchronization Technique for Three-Phase Grid-Interfaced Converters in Distributed Utility Networks [J].
Guo, Xiaoqiang ;
Wu, Weiyang ;
Chen, Zhe .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) :1194-1204
[8]   Input-admittance calculation and shaping for controlled voltage-source converters [J].
Harnefors, Lennart ;
Bongiorno, Massimo ;
Lundberg, Stefan .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2007, 54 (06) :3323-3334
[9]   VSC transmission model for analytical studies [J].
Jovcic, D ;
Lamont, LA .
2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, :1737-1742
[10]   Performance characterization of a non-linear system as both an adaptive notch filter and a phase-locked loop [J].
Karimi-Ghartemani, M ;
Ziarani, AK .
INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2004, 18 (01) :23-53