Measurement of Corneal Biomechanical Properties in Diabetes Mellitus Using the Ocular Response Analyzer and the Corvis ST

被引:28
作者
Ramm, Lisa [1 ]
Herber, Robert [1 ]
Spoerl, Eberhard [1 ]
Pillunat, Lutz E. [1 ]
Terai, Naim [1 ]
机构
[1] Univ Hosp Dresden, Dept Ophthalmol, Dresden, Germany
关键词
ocular response analyzer; Corvis ST; biomechanics; diabetes mellitus; INTRAOCULAR-PRESSURE; IN-VIVO; NONENZYMATIC GLYCATION; KERATOCONUS; PARAMETERS; PACHYMETRY; HEALTHY;
D O I
10.1097/ICO.0000000000001879
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Hyperglycemia in diabetes mellitus (DM) might induce changes in corneal biomechanics. Therefore, biomechanical properties of the cornea were measured using the ocular response analyzer and the Corvis ST. Methods: In the study, 35 eyes of 35 diabetic patients were included. After an ophthalmological examination, measurements with the ocular response analyzer and the Corvis ST were taken. Additionally, biometry and corneal topography were performed and HbA1c values were collected. Results were compared to an age-, pachymetry-and intraocular pressure-matched group of 35 healthy subjects. Results: Mean age (67.6 6 10.3; 64.1 6 8.3 years), intraocular pressure (13.4 6 2.9; 12.8 6 2.8 mm Hg), and central corneal thickness (556.4 6 31.7; 548.6 6 32.9 mm) were not significantly different between the groups (P. 0.05). In DM, the corneal hysteresis (CH) and the corneal resistance factor (CRF) were increased (CH: 10.8 6 2 vs. 9.4 6 1.6, P = 0.002; CRF: 10.6 6 2.1 vs. 9.6 6 1.5, P = 0.022). Also, most dynamic corneal response parameters showed significant differences. Beside others, A1 and A2 deflection amplitudes were increased (P, 0.001) and highest concavity and A2 time were extended (P, 0.001 and 0.007) in DM. According to current HbA1c value, DM was classified as controlled (# 7%) and poorly controlled (. 7%) and significant biomechanical differences were measured between both groups. Conclusions: In DM, significant changes in corneal biomechanical properties were detectable. In patients, CH and CRF were increased and most dynamic corneal response parameters were different compared to healthy subjects.
引用
收藏
页码:595 / 599
页数:5
相关论文
共 37 条
[1]   Biomechanical Responses of Healthy and Keratoconic Corneas Measured Using a Noncontact Scheimpflug-Based Tonometer [J].
Ali, Noor Q. ;
Patel, Dipika V. ;
McGhee, Charles N. J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (06) :3651-3659
[2]  
Ambrosio Renato Jr, 2017, Open Ophthalmol J, V11, P176, DOI 10.2174/1874364101711010176
[3]   Repeatability, Reproducibility, and Age Dependency of Dynamic Scheimpflug-Based Pneumotonometer and Its Correlation With a Dynamic Bidirectional Pneumotonometry Device [J].
Bak-Nielsen, Sashia ;
Pedersen, Iben Bach ;
Ivarsen, Anders ;
Hjortdal, Jesper .
CORNEA, 2015, 34 (01) :71-77
[4]   Effects of diabetes mellitus on biomechanical properties of the rabbit cornea [J].
Bao, FangJun ;
Deng, ManLi ;
Zheng, XiaoBo ;
Li, LinNa ;
Zhao, YiPing ;
Cao, Si ;
Yu, AYong ;
Wang, QinMei ;
Huang, JinHai ;
Elsheikh, Ahmed .
EXPERIMENTAL EYE RESEARCH, 2017, 161 :82-88
[5]   Clinical Evaluation of Methods to Correct Intraocular Pressure Measurements by the Goldmann Applanation Tonometer, Ocular Response Analyzer, and Corvis ST Tonometer for the Effects of Corneal Stiffness Parameters [J].
Bao, FangJun ;
Huang, ZiXu ;
Huang, JinHai ;
Wang, JunJie ;
Deng, ManLi ;
Li, LinNa ;
Yu, AYong ;
Wang, QinMei ;
Elsheikh, Ahmed .
JOURNAL OF GLAUCOMA, 2016, 25 (06) :510-519
[6]   Age-related changes on the surface of vitreous collagen fibrils [J].
Bishop, PN ;
Holmes, DF ;
Kadler, KE ;
McLeod, D ;
Bos, KJ .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (04) :1041-1046
[7]  
Bowling B., 2016, Kanski's Clinical Ophthalmology
[8]   Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging [J].
Chan, Tommy C. Y. ;
Biswas, Sayantan ;
Yu, Marco ;
Jhanji, Vishal .
ACTA OPHTHALMOLOGICA, 2017, 95 (06) :E486-E494
[9]   Systematic Review of the Agreement of Tonometers with Goldmann Applanation Tonometry [J].
Cook, Jonathan Alistair ;
Botello, Adriana Paola ;
Elders, Andrew ;
Ali, Alia Fathi ;
Azuara-Blanco, Augusto ;
McCormack, Kirsty ;
Burr, Jennifer Margaret .
OPHTHALMOLOGY, 2012, 119 (08) :1552-1557
[10]   Effect of diabetes mellitus on biomechanical parameters of the cornea [J].
Goldich, Yakov ;
Barkana, Yaniv ;
Gerber, Yariv ;
Rasko, Adi ;
Morad, Yair ;
Harstein, Morris ;
Avni, Isaac ;
Zadok, David .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) :715-719