Calculation of the overhead transmission line conductor temperature in real operating conditions

被引:15
作者
Bena, Lubomir [1 ]
Gall, Vladimir [1 ]
Kanalik, Martin [1 ]
Kolcun, Michal [1 ]
Margitova, Anastazia [1 ]
Meszaros, Alexander [1 ]
Urbansky, Jakub [1 ]
机构
[1] Tech Univ Kosice, Fac Elect Engn & Informat, Dept Elect Power Engn, Letna 9, Kosice 04200, Slovakia
关键词
Transmission line; ACSR conductor; CIGRE Technical Brochure 601; CIGRE Technical Brochure 207; Differential equation; Operating temperature; Weather conditions; AMPACITY MODEL; IEEE;
D O I
10.1007/s00202-020-01107-2
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The integration of fluctuating renewable sources, load growth and aging of the current power system is the major reasons for the development of the electric power engineering. Transmission lines are recently facing new technical and economic challenges. The immediate utilization of advanced technologies and modern methods could solve these issues. This study deals with the transmission and distribution of electrical energy with orientation on the calculation of operating temperature on the conductor of transmission line, which is under actual current load. The load of the transmission line is limited with allowable operating temperature. The operating temperature should not exceed the allowable operating temperature because the conductors of the transmission line have mechanical limit from the standpoint of deflection of conductors. The operating temperature as well as operating conditions of the conductor is determined by the type and material of the ACSR conductor. This article aims to propose the suitable calculation methods of the operating temperature of the overhead transmission line conductor in real operating conditions (external weather influences, current loading and corona effect). The originality of this proposed method (by differential equation) lies in considering corona effect. This improves the accuracy of the calculation of the operating temperature of the conductor under real conditions. In this article, the calculations are compared according to methodology of differential equation and methodology described in CIGRE Technical Brochure 601-guide for thermal rating calculations of overhead lines. The methodology of differential equation counts with or without losses by corona. The article also compares these methods of operating temperature during days in various different weather conditions like environment temperature, solar irradiance, wind speed and direction. It was found that under the action of the corona, the temperature of the conductor increases to a small extent.
引用
收藏
页码:769 / 780
页数:12
相关论文
共 50 条
  • [21] Methodology for Overhead Line Conductor Remaining Life Aging infrastructure and asset management
    Velasquez, R. M. A.
    Lara, J. V. M.
    PROCEEDINGS OF THE 2018 IEEE PES TRANSMISSION & DISTRIBUTION CONFERENCE AND EXHIBITION - LATIN AMERICA (T&D-LA), 2018,
  • [22] Approximate Relationships for Calculation of Current-Carrying Capacity of Overhead Power Transmission Lines in Different Weather Conditions
    Zenczak, Michal
    2017 PROGRESS IN APPLIED ELECTRICAL ENGINEERING (PAEE), 2017,
  • [23] Determining Transmission Line Conductor Condition and Remaining Life
    Tsimberg, Y.
    Lotho, K.
    Dimnik, C.
    Wrathall, N.
    Mogilevsky, A.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [24] Development of Automatic Device for Conductor Crimping of Transmission Line
    Liu Yanmei
    Zhang Dongyu
    Chen Zhen
    Wen Shihua
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 3496 - 3500
  • [25] Temperature safety analysis and backup protection scheme improvement for overhead transmission line in power oscillation condition
    Wang, Jian
    Chen, Jing
    Xiong, Xiaofu
    Lu, Xiaofeng
    Liao, Zheng
    Chen, Xiaobo
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 166 : 88 - 98
  • [26] Overhead Transmission Line 750 kV Model with Bundle Wire
    Glushkov, Daniil A.
    Zinovev, Kirill A.
    PROCEEDINGS OF THE 2017 IEEE RUSSIA SECTION YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING CONFERENCE (2017 ELCONRUS), 2017, : 1152 - 1155
  • [27] Fault Investigation and Analysis of an Overhead Transmission Line Vibration Damper
    Hickey, Conor
    Young, Paul
    Mayomi, Tolulope
    Noctor, Jason
    2021 56TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC 2021): POWERING NET ZERO EMISSIONS, 2021,
  • [28] Method for Calculating of Lightning Impact Level on Overhead Transmission Line
    Burtsev, Anton Vladimirovich
    Selivanov, Vasily Nikolaevich
    APPLIED SCIENCES-BASEL, 2021, 11 (14):
  • [29] New Methodology of On-line Monitoring for High Voltage Overhead Transmission Line Icing
    Quan, Yusheng
    Zhou, Enze
    Chen, Huagui
    Zhao, Xin
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 871 - +
  • [30] Calculation Method of Conductor Sag Based on Radial Temperature and Creep
    Zhao L.
    Wang R.
    Dai P.
    Zhu C.
    Huang X.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2023, 55 (04): : 21 - 29