Voltage-current characteristics of a pin-plate system with different plate configurations

被引:2
作者
Feng, Zhuangbo [1 ]
Long, Zhengwei [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Technol, Tianjin 300072, Peoples R China
来源
7TH INTERNATIONAL CONFERENCE ON APPLIED ELECTROSTATICS (ICAES-2012) | 2013年 / 418卷
关键词
SIMULATION; CORONA;
D O I
10.1088/1742-6596/418/1/012097
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, the voltage-current (V-I) characteristics of a pin-plate system with four types of collection plate configurations are studied experimentally. The collection plates consider a single metal plate, a metal plate with a fly ash cake layer, a metal plate with a clean filter media and a metal plate with a dirty filter media. The results show that the clean filter media has no obvious effect on the V-I characteristics. But the dirty filter media reduces the current density because of its high resistance. The thick fly ash cake layer increase current density because of the anti-corona effect but the increment is not very obvious.
引用
收藏
页数:7
相关论文
共 10 条
[1]   Simulation of corona discharge in point-plane configuration [J].
Adamiak, K ;
Atten, P .
JOURNAL OF ELECTROSTATICS, 2004, 61 (02) :85-98
[2]   SIMULATION OF CORONA IN WIRE-DUCT ELECTROSTATIC PRECIPITATOR BY MEANS OF THE BOUNDARY-ELEMENT METHOD [J].
ADAMIAK, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (02) :381-386
[3]   Ventilation filters and indoor air quality: a review of research from the International Centre for Indoor Environment and Energy [J].
Clausen, G .
INDOOR AIR, 2004, 14 :202-207
[4]   Removal of viable bioaerosol particles with a low-efficiency HVAC filter enhanced by continuous emission of unipolar air ions [J].
Huang, R. ;
Agranovski, I. ;
Pyankov, O. ;
Grinshpun, S. .
INDOOR AIR, 2008, 18 (02) :106-112
[5]  
Long Z W, 2012, POWDER TECHNOL, V26, P215
[6]  
Long Zheng-wei, 2010, Proceedings of the CSEE, V30, P13
[7]  
Miller J, 2000, J ELECTROSTAT, V58, P197
[8]  
Park J, 2009, MECH SCI TECHNOL, V23, P184
[9]   Removal of submicron particles using a carbon fiber ionizer-assisted medium air filter in a heating, ventilation, and air-conditioning (HVAC) system [J].
Park, Jae Hong ;
Yoon, Ki Young ;
Hwang, Jungho .
BUILDING AND ENVIRONMENT, 2011, 46 (08) :1699-1708
[10]   Reducing particle exposures in a tropical office building using electrostatic precipitators [J].
Zuraimi, M. S. ;
Tham, K. W. .
BUILDING AND ENVIRONMENT, 2009, 44 (12) :2475-2485