On shimming approaches in 3T breast MRI

被引:27
作者
Hancu, Ileana [1 ]
Govenkar, Ambey [2 ]
Lenkinski, Robert E. [3 ]
Lee, Seung-Kyun [1 ]
机构
[1] GE Global Res Ctr, Niskayuna, NY 12309 USA
[2] Extenprise Inc, Pune, Maharashtra, India
[3] Univ Texas SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
关键词
breast; MRI; shimming; 3; T; B0;
D O I
10.1002/mrm.24307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A comparative study is presented, analyzing quantitatively the impact of 15 shim strategies on the homogeneity of the main magnetic field over the three-dimensional breast region in 3T MRI. The results obtained in 12 female volunteers, spanning a wide range of body and breast types, indicate that the inclusion of the back and heart in the shim region of interest leads to considerable decrease in field homogeneity, and needs to be avoided. Comparison between shim strategies using volumetric B0 maps, covering the entire breast region, and 16 plane B0 maps indicate only minimally reduced performance for the latter. Interestingly, however, no single shim strategy relying on a limited number of B0 maps as input was found to work best in all volunteers. This was attributed to the limited capability of a small number of B0 maps to capture the B0 variability existent within breast. On the average, a rectangular shim region of interest, encompassing the breast region alone, worked best for the cohort studied here. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:862 / 867
页数:6
相关论文
共 11 条
[1]  
Bleicher RJ, 2007, ONCOLOGY-NY, V21, P1521
[2]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[3]  
Han M, 2009, P 17 ANN M ISMRM HON, P580
[4]   Breast MR imaging artifacts: How to recognize and fix them [J].
Harvey, Jennifer A. ;
Hendrick, R. Edward ;
Coll, Jennifer M. ;
Nicholson, Brandi T. ;
Burkholder, Brian T. ;
Cohen, Michael A. .
RADIOGRAPHICS, 2007, 27 :S131-S145
[5]  
Kim DH, 2002, P 10 ANN M ISMRM HON, P636
[6]   Strategies for shimming the breast [J].
Maril, N ;
Collins, CM ;
Greenman, RL ;
Lenkinski, RE .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (05) :1139-1145
[7]   MRI-guided breast biopsy at 3T using a dedicated large core biopsy set: Feasibility and initial results [J].
Meeuwis, Carla ;
Mann, Ritse M. ;
Mus, Roel. D. M. ;
Winkel, Axel ;
Boetes, Carla ;
Barentsz, Jelle O. ;
Veltman, Jeroen .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) :257-261
[8]   Dynamic shimming for multi-slice magnetic resonance imaging [J].
Morrell, G ;
Spielman, D .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (03) :477-483
[9]   Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): Application with fast spin-echo imaging [J].
Reeder, SB ;
Pineda, AR ;
Wen, ZF ;
Shimakawa, A ;
Yu, HZ ;
Brittain, JH ;
Gold, GE ;
Beaulieu, CH ;
Pelc, NJ .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) :636-644
[10]   Single-shot magnetic field mapping embedded in echo-planar time-course imaging [J].
Roopchansingh, V ;
Cox, RW ;
Jesmanowicz, A ;
Ward, BD ;
Hyde, JS .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) :839-843