Active Breathing Control in Combination With Ultrasound Imaging: A Feasibility Study of Image Guidance in Stereotactic Body Radiation Therapy of Liver Lesions

被引:21
作者
Bloemen-van Gurp, Esther [1 ]
van der Meer, Skadi [1 ]
Hendry, Janet [1 ]
Buijsen, Jeroen [1 ]
Visser, Peter [1 ]
Fontanarosa, Davide [1 ]
Lachaine, Martin [2 ]
Lammering, Guido [1 ]
Verhaegen, Frank [1 ,3 ]
机构
[1] Maastricht Univ, Med Ctr, GROW Sch Oncol & Dev Biol, Dept Radiat Oncol MAASTRO, NL-6201 BN Maastricht, Netherlands
[2] Elekta Ltd, Montreal, PQ, Canada
[3] McGill Univ, Dept Oncol, Med Phys Unit, Montreal, PQ, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2013年 / 85卷 / 04期
关键词
SPEED;
D O I
10.1016/j.ijrobp.2012.08.016
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Accurate tumor positioning in stereotactic body radiation therapy (SBRT) of liver lesions is often hampered by motion and setup errors. We combined 3-dimensional ultrasound imaging (3DUS) and active breathing control (ABC) as an image guidance tool. Methods and Materials: We tested 3DUS image guidance in the SBRT treatment of liver lesions for 11 patients with 88 treatment fractions. In 5 patients, 3DUS imaging was combined with ABC. The uncertainties of US scanning and US image segmentation in liver lesions were determined with and without ABC. Results: In free breathing, the intraobserver variations were 1.4 mm in left-right (L-R), 1.6 mm in superior-inferior (S-I), and 1.3 mm anterior-posterior (A-P). and the interobserver variations were 1.6 mm (L-R), 2.8 mm (S-I), and 1.2 mm (A-P). The combined uncertainty of US scanning and matching (inter-and intraobserver) was 4 mm (1 SD). The combined uncertainty when ABC was used reduced by 1.7 mm in the S-I direction. For the L-R and A-P directions, no significant difference was observed. Conclusion: 3DUS imaging for IGRT of liver lesions is feasible, although using anatomic surrogates in the close vicinity of the lesion may be needed. ABC-based breath-hold in midventilation during 3DUS imaging can reduce the uncertainty of US-based 3D table shift correction. (C) 2013 Elsevier Inc.
引用
收藏
页码:1096 / 1102
页数:7
相关论文
共 9 条
  • [1] Boda-Heggemann J, 2006, STRAHLENTHER ONKOL, V182, P216, DOI 10.1007/s00066-006-1453-8
  • [2] INTER- AND INTRAFRACTION VARIABILITY IN LIVER POSITION IN NON-BREATH-HOLD STEREOTACTIC BODY RADIOTHERAPY
    Case, Robert B.
    Sonke, Jan-Jakob
    Moseley, Douglas J.
    Kim, John
    Brock, Kristy K.
    Dawson, Laura A.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 302 - 308
  • [3] A CT based correction method for speed of sound aberration for ultrasound based image guided radiotherapy
    Fontanarosa, Davide
    Van der Meer, Skadi
    Harris, Emma
    Verhaegen, Frank
    [J]. MEDICAL PHYSICS, 2011, 38 (05) : 2665 - 2673
  • [4] Daily ultrasound-based image-guided targeting for radiotherapy of upper abdominal malignancies
    Fuss, M
    Salter, BJ
    Cavanaugh, SX
    Fuss, C
    Sadeghi, A
    Fuller, CD
    Ameduri, A
    Hevezi, JM
    Herman, TS
    Thomas, CR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (04): : 1245 - 1256
  • [5] Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: A case report
    Hennessey H.
    Valenti D.
    Cabrera T.
    Panet-Raymond V.
    Roberge D.
    [J]. Journal of Medical Case Reports, 3 (1)
  • [6] Evaluation of alignment error due to a speed artifact in stereotactic ultrasound image guidance
    Salter, Bill J.
    Wang, Brian
    Szegedi, Martin W.
    Rassiah-Szegedi, Prema
    Shrieve, Dennis C.
    Cheng, Roger
    Fuss, Martin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (23) : N437 - N445
  • [7] Treatment precision of image-guided liver SBRT using implanted fiducial markers depends on marker-tumour distance
    Seppenwoolde, Y.
    Wunderink, W.
    Wunderink-van Veen, S. R.
    Storchi, P.
    Romero, A. Mendez
    Heijmen, B. J. M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (17) : 5445 - 5468
  • [8] Respiratory correlated cone beam CT
    Sonke, JJ
    Zijp, L
    Remeijer, P
    van Herk, M
    [J]. MEDICAL PHYSICS, 2005, 32 (04) : 1176 - 1186
  • [9] EFFECT OF BREATHING MOTION ON RADIOTHERAPY DOSE ACCUMULATION IN THE ABDOMEN USING DEFORMABLE REGISTRATION
    Velec, Michael
    Moseley, Joanne L.
    Eccles, Cynthia L.
    Craig, Tim
    Sharpe, Michael B.
    Dawson, Laura A.
    Brock, Kristy K.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 265 - 272