Clinical Evaluation and Potential Radiation Dose Reduction of the Novel Sinograrn-affirmed Iterative Reconstruction Technique (SAFIRE) in Abdominal Computed Tomography Angiography

被引:35
作者
Schabel, Christoph [1 ]
Fenchel, Michael [2 ]
Schmidt, Bernhard [4 ]
Flohr, Thomas G. [1 ,4 ]
Wuerslin, Christian [3 ]
Thomas, Christoph [1 ]
Korn, Andreas [1 ]
Tsiflikas, Ilias [1 ]
Claussen, Claus D. [1 ]
Heuschnnid, Martin [1 ]
Ketelsen, Dominik [1 ]
机构
[1] Univ Tubingen Hosp, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Diagnost & Intervent Neuroradiol, D-72076 Tubingen, Germany
[3] Univ Tubingen Hosp, Sect Expt Radiol, D-72076 Tubingen, Germany
[4] Siemens Healthcare, Computed Tomog, Forchheim, Germany
关键词
Iterative reconstruction; SAFIRE; CT; CTA; dose reduction; ENDOVASCULAR REPAIR; AORTIC-ANEURYSM; COMPLICATIONS; EXPOSURE; ADULT; NOISE;
D O I
10.1016/j.acra.2012.08.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: Computed tomographic angiography is the standard in routine follow-up after endovascular aneurysm repair, causing radiation exposure; thus, dose-saving strategies should be applied. The aim of this study was to evaluate the novel sinogram-affirmed iterative reconstruction (SAFIRE) algorithm in terms of clinical usability and potential reduction of radiation exposure. Materials and Methods: Forty-six patients underwent computed tomographic angiographic follow-up after endovascular aneurysm repair. Data were acquired using a dual-source computed tomographic scanner running both x-ray tubes at the same voltage (120 kV). Raw data were reconstructed using projections of both tubes with filtered back projection (FBP) and of only one tube with FBP and SAFIRE, corresponding to synthetic acquisition with half the radiation dose of the clinical routine radiation dose. Image sets were objectively compared regarding signal-to-noise ratio and edge sharpness. Two radiologists independently assessed a set of subjective criteria, including diagnostic usability, depiction of contrasted vessels, and image noise. Results: Half-dose (HD) SAFIRE images showed significantly higher signal-to-noise ratios compared to full-dose FBP images (P < .001), while having equal edge sharpness (P = .56). Most of the subjectively assessed parameters, such as diagnostic usability and depiction of contrasted vessels, were rated similar for HD SAFIRE and full-dose FBP images. Full-dose FBP images depicted fine anatomic structures more clearly (P < .05), while HD SAFIRE data sets showed less noise (P < .01). HD FBP images performed worse on all criteria (P < .001). Interrater agreement was good (K = 0.74-0.80). Conclusions: Using the SAFIRE algorithm, the radiation dose of high-contrast abdominal computed tomographic angiography is reducible from routine clinical levels by up to 50% while maintaining good image quality and diagnostic accuracy.
引用
收藏
页码:165 / 172
页数:8
相关论文
共 21 条
[1]   State of the art low-dose CT angiography of the body [J].
Alkadhi, Hatem ;
Schindera, Sebastian T. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (01) :36-40
[2]   THEORY OF IMAGE RECONSTRUCTION IN COMPUTED TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
RADIOLOGY, 1975, 117 (03) :561-572
[3]   Estimating Effective Dose for CT Using Dose-Length Product Compared With Using Organ Doses: Consequences of Adopting International Commission on Radiological Protection Publication 103 or Dual-Energy Scanning [J].
Christner, Jodie A. ;
Kofler, James M. ;
McCollough, Cynthia H. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (04) :881-889
[4]   A review of patient dose and optimisation methods in adult and paediatric CT scanning [J].
Dougeni, E. ;
Faulkner, K. ;
Panayiotakis, G. .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) :E665-E683
[5]   CT iterative reconstruction in image space: A phantom study [J].
Ghetti, C. ;
Ortenzia, O. ;
Serreli, G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :161-165
[6]   Low-dose multidetector-row CT-angiography of abdominal aortic aneurysm after endovascular repair [J].
Iezzi, R. ;
Cotroneo, A. R. ;
Giammarino, A. ;
Spigonardo, F. ;
Storto, M. L. .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) :21-28
[7]   Radiation Dose Reduction With Sinogram Affirmed Iterative Reconstruction Technique for Abdominal Computed Tomography [J].
Kalra, Mannudeep K. ;
Woisetschlager, Mischa ;
Dahlstrom, Nils ;
Singh, Sarabjeet ;
Lindblom, Maria ;
Choy, Garry ;
Quick, Petter ;
Schmidt, Bernhard ;
Sedlmair, Martin ;
Blake, Michael A. ;
Persson, Anders .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (03) :339-346
[8]   A Prospective Comparison of Standard-Dose CT Enterography and 50% Reduced-Dose CT Enterography With and Without Noise Reduction for Evaluating Crohn Disease [J].
Lee, So Jung ;
Park, Seong Ho ;
Kim, Ah Young ;
Yang, Suk-Kyun ;
Yun, Sung-Cheol ;
Lee, Seung Soo ;
Jung, Gyoo Sik ;
Ha, Hyun Kwon .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (01) :50-57
[9]   Update: Complications and management of infrarenal EVAR [J].
Liaw, J. V. P. ;
Clark, M. ;
Gibbs, R. ;
Jenkins, M. ;
Cheshire, N. ;
Hamady, A. .
EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (03) :541-551
[10]   Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography [J].
May, Matthias S. ;
Wuest, Wolfgang ;
Brand, Michael ;
Stahl, Christian ;
Allmendinger, Thomas ;
Schmidt, Bernhard ;
Uder, Michael ;
Lell, Michael M. .
INVESTIGATIVE RADIOLOGY, 2011, 46 (07) :465-470