High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI)

被引:25
|
作者
Han, Yang [1 ]
Hou, Gary Yi [1 ]
Wang, Shutao [1 ]
Konofagou, Elisa [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Radiol, New York, NY 10027 USA
基金
美国国家卫生研究院;
关键词
HMIFU; HIFU; focal spot localization; ACOUSTIC RADIATION FORCE; DIAGNOSTIC ULTRASOUND; IN-VITRO; LIVER; ELASTOGRAPHY; FEASIBILITY; VALIDATION; DEPENDENCE; ABLATION; TISSUES;
D O I
10.1088/0031-9155/60/15/5911
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of high-intensity focused ultrasound (HIFU) treatment. However, accurate localization and characterization of the effective region of treatment (focal spot) remain important obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a HIFU monitoring technique that utilizes radiation-force-induced localized oscillatory displacement. HMIFU has been shown to correctly identify the formation and extent of HIFU thermal ablation lesions. However a significant problem remains in identifying the location of the HIFU focus, which is necessary for treatment planning. In this study, the induced displacement was employed to localize the HIFU focal spot inside the tissue prior to treatment. Feasibility was shown with two separate systems. The 1D HMIFU system consisted of a HIFU transducer emitting an amplitude-modulated HIFU beam for mechanical excitation and a confocal single-element, pulse-echo transducer for simultaneous RF acquisition. The 2D HIFU system consists of a HIFU phased array, and a co-axial imaging phased array for simultaneous imaging. Initial feasibility was first performed on tissue-mimicking gelatin phantoms and the focal zone was defined as the region corresponding to the -3dB full width at half maximum of the HMI displacement. Using the same parameters, in vitro experiments were performed in canine liver specimens to compare the defined focal zone with the lesion. In vitro measurements showed good agreement between the HMI predicted focal zone and the induced HIFU lesion location. HMIFU was experimentally shown to be capable of predicting and tracking the focal region in both phantoms and in vitro tissues. The accuracy of focal spot localization was evaluated by comparing with the lesion location in post-ablative tissues, with a R-2 = 0.821 at p < 0.002 in the 2D HMI system. We demonstrated the feasibility of using this HMI-based technique to localize the HIFU focal spot without inducing thermal changes during the planning phase. The focal spot localization method has also been applied on ex vivo human breast tissue ablation and can be fully integrated into any HMI system for planning purposes.
引用
收藏
页码:5911 / 5924
页数:14
相关论文
共 50 条
  • [31] Optimization of Phase Shift of the Transducer for High Intensity Focused Ultrasound (HIFU)
    Yamamoto, Mariko
    Yoshizawa, Shin
    Umemura, Shin-ichiro
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012, : 1625 - 1628
  • [32] Quantitative Ultrasound Imaging for Monitoring In Situ High-Intensity Focused Ultrasound Exposure
    Ghoshal, Goutam
    Kemmerer, Jeremy P.
    Karunakaran, Chandra
    Abuhabsah, Rami
    Miller, Rita J.
    Sarwate, Sandhya
    Oelze, Michael L.
    ULTRASONIC IMAGING, 2014, 36 (04) : 239 - 255
  • [33] High intensity focused ultrasound (HIFU) for primary hepatocellular carcinoma: a single center experience
    Ji, Yongshuo
    Zhang, Yu
    Zhu, Junqiu
    Zhu, Linglin
    Zhu, Yanfei
    Hu, Kaimeng
    Zhao, Hong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (11): : 15432 - 15438
  • [34] Damage characteristics of elastic material through a thin membrane using high-intensity focused ultrasound (HIFU)
    Liu, N. N.
    Cui, Y. D.
    Khoo, B. C.
    Zhang, A. M.
    AIP ADVANCES, 2018, 8 (11):
  • [35] Real-Time Photoacoustic Thermometry Combined With Clinical Ultrasound Imaging and High-Intensity Focused Ultrasound
    Kim, Jeesu
    Choi, Wonseok
    Park, Eun-Yeong
    Kang, Youngnam
    Lee, Ki Jong
    Kim, Hyung Ham
    Kim, Won Jong
    Kim, Chulhong
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (12) : 3330 - 3338
  • [36] High-intensity focused ultrasound for focal therapy: reality or pitfall?
    Schulman, Ariel A.
    Tay, Kae Jack
    Robertson, Cary N.
    Polascik, Thomas J.
    CURRENT OPINION IN UROLOGY, 2017, 27 (02) : 138 - 148
  • [37] Ultrasound Delta CBE Imaging: A New Approach Based on Local Energy Subtraction to Localization of the HIFU Focal Spot Using Changes in Backscattered Energy
    Yang, Kun
    Li, Qiang
    Zhou, Xiaowei
    Wang, Chiao-Yin
    Tsui, Po-Hsiang
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2024, 44 (04) : 618 - 627
  • [38] Noninvasive cardiac arrhythmia therapy using High-Intensity Focused Ultrasound (HIFU) ablation
    Wu, Qi
    Zhou, Qi
    Zhu, Que
    Rong, Shunkang
    Wang, Qi
    Guo, Rui
    Deng, Changming
    Liu, Dichuan
    Yang, Gang
    Jiang, Yonghong
    Wang, ZhiGang
    Lei, Han
    He, Tong-Chuan
    Wang, ZhiBiao
    Huang, Jing
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 166 (02) : E28 - E30
  • [39] Detection of gaps between high-intensity focused ultrasound (HIFU)-induced lesions using transient axial shear strain elastograms
    Liu, Chenhui
    Zhou, Yufeng
    MEDICAL PHYSICS, 2018, 45 (08) : 3831 - 3847
  • [40] Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MR-HIFU): Overview of Emerging Applications (Part 2)
    Siedek, Florian
    Yeo, Sin Yuin
    Heijman, Edwin
    Grinstein, Olga
    Bratke, Grischa
    Heneweer, Carola
    Puesken, Michael
    Persigehl, Thorsten
    Maintz, David
    Gruell, Holger
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2019, 191 (06): : 531 - 539