High intensity focused ultrasound (HIFU) focal spot localization using harmonic motion imaging (HMI)

被引:25
|
作者
Han, Yang [1 ]
Hou, Gary Yi [1 ]
Wang, Shutao [1 ]
Konofagou, Elisa [1 ,2 ]
机构
[1] Columbia Univ, Dept Biomed Engn, New York, NY 10027 USA
[2] Columbia Univ, Dept Radiol, New York, NY 10027 USA
基金
美国国家卫生研究院;
关键词
HMIFU; HIFU; focal spot localization; ACOUSTIC RADIATION FORCE; DIAGNOSTIC ULTRASOUND; IN-VITRO; LIVER; ELASTOGRAPHY; FEASIBILITY; VALIDATION; DEPENDENCE; ABLATION; TISSUES;
D O I
10.1088/0031-9155/60/15/5911
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Several ultrasound-based imaging modalities have been proposed for image guidance and monitoring of high-intensity focused ultrasound (HIFU) treatment. However, accurate localization and characterization of the effective region of treatment (focal spot) remain important obstacles in the clinical implementation of HIFU ablation. Harmonic motion imaging for focused ultrasound (HMIFU) is a HIFU monitoring technique that utilizes radiation-force-induced localized oscillatory displacement. HMIFU has been shown to correctly identify the formation and extent of HIFU thermal ablation lesions. However a significant problem remains in identifying the location of the HIFU focus, which is necessary for treatment planning. In this study, the induced displacement was employed to localize the HIFU focal spot inside the tissue prior to treatment. Feasibility was shown with two separate systems. The 1D HMIFU system consisted of a HIFU transducer emitting an amplitude-modulated HIFU beam for mechanical excitation and a confocal single-element, pulse-echo transducer for simultaneous RF acquisition. The 2D HIFU system consists of a HIFU phased array, and a co-axial imaging phased array for simultaneous imaging. Initial feasibility was first performed on tissue-mimicking gelatin phantoms and the focal zone was defined as the region corresponding to the -3dB full width at half maximum of the HMI displacement. Using the same parameters, in vitro experiments were performed in canine liver specimens to compare the defined focal zone with the lesion. In vitro measurements showed good agreement between the HMI predicted focal zone and the induced HIFU lesion location. HMIFU was experimentally shown to be capable of predicting and tracking the focal region in both phantoms and in vitro tissues. The accuracy of focal spot localization was evaluated by comparing with the lesion location in post-ablative tissues, with a R-2 = 0.821 at p < 0.002 in the 2D HMI system. We demonstrated the feasibility of using this HMI-based technique to localize the HIFU focal spot without inducing thermal changes during the planning phase. The focal spot localization method has also been applied on ex vivo human breast tissue ablation and can be fully integrated into any HMI system for planning purposes.
引用
收藏
页码:5911 / 5924
页数:14
相关论文
共 50 条
  • [21] CALIBRATION OF ULTRASOUND BACKSCATTER TEMPERATURE IMAGING FOR HIGH-INTENSITY FOCUSED ULTRASOUND TREATMENT PLANNING
    Civale, John
    Rivens, Ian
    Ter Haar, Gail
    Morris, Hugh
    Coussios, Constantin
    Friend, Peter
    Bamber, Jeffrey
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (09) : 1596 - 1612
  • [22] The Study of Sub-Harmonic Cavitation Imaging Based on Pulse Inversion Technique for the Monitoring of High Intensity Focused Ultrasound Therapies
    Zhong, Hui
    Ding, Guanhua
    She, Yanmin
    Zong, Yujin
    Wan, Mingxi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (03) : 410 - 415
  • [23] Development of a High Intensity Focused Ultrasound (HIFU) hydrophone system
    Schafer, Mark E.
    Gessert, James
    Moore, Wayne
    THERAPEUTIC ULTRASOUND, 2006, 829 : 609 - +
  • [24] High Intensity Focused Ultrasound (HIFU) for Biomedical and Dentistry Applications
    Khoo, Boo Cheong
    Ohl, Siew-Wan
    Klaseboer, Evert
    XIV MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2016, 2016, 57 : 738 - 741
  • [25] Development of a High Intensity Focused Ultrasound (HIFU) Hydrophone System
    Schafer, Mark E.
    Gessert, James
    8TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2009, 1113 : 301 - +
  • [26] High intensity focused ultrasound: Imaging is the key!
    Shehata, I. A.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (06) : 569 - 572
  • [28] Effects of tracking beam dimensions on Harmonic Motion Imaging (HMI) with electronic beam steering of focused ultrasound (FUS)
    Liu, Yangpei
    Saharkhiz, Niloufar
    Hossain, Murad
    Konofagou, Elisa E.
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [29] Prospective multicentre study using high intensity focused ultrasound (HIFU) for the focal treatment of prostate cancer: Safety outcomes and complications
    Schmid, F. A.
    Schindele, D.
    Mortezavi, A.
    Spitznagel, T.
    Sulser, T.
    Schostak, M.
    Eberli, D.
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2020, 38 (04) : 225 - 230
  • [30] High intensity focused ultrasound (HIFU) for the treatment of symptomatic breast fibroadenoma
    Hahn, M.
    Fugunt, R.
    Schoenfisch, B.
    Oberlechner, E.
    Gruber, I. V.
    Hoopmann, U.
    Roehm, C.
    Helms, G.
    Taran, F. A.
    Hartkopf, A. D.
    Warzecha, H.
    Wiesinger, B.
    Brucker, S. Y.
    Boeer, B.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 35 (01) : 463 - 470