Load-reversed push-out tests have been carried out on 6 rectangular concrete-filled steel tubular (CFST) columns with the aim of investigating the nature of the bond between the concrete infill and the steel tube, the contribution of each bond stress component (i.e. chemical adhesion, microlocking and macrolocking) and the development of macrolocking within four half-cycles of loading. The contribution of microlocking to the total bond strength was obtained from the comparison between the ultimate strength of normal specimens and lubricated specimens, which also revealed the detrimental effect of lubrication on the bond strength. The macrolocking contribution was obtained from the comparison between the ultimate strength achieved in the first half-cycle of loading tau(u1) and the ultimate strength achieved in the third half-cycle of loading tau(u3) of the non-lubricated specimens. The developed bond mechanisms were explained and details of the interface bond stress distribution were obtained from the recorded axial strain gradients in the steel tube. Finally, the concept of a critical shear force transfer length was introduced, and its implications on practical design discussed. Crown Copyright (C) 2012 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 50 条
  • [1] Push-out tests and bond strength of rectangular CFST columns
    Qu, Xiushu
    Chen, Zhihua
    Nethercot, David A.
    Gardner, Leroy
    Theofanous, Marios
    STEEL AND COMPOSITE STRUCTURES, 2015, 19 (01): : 21 - 41
  • [2] Post-fire load-reversed push-out performance of normal and lightweight concrete-filled steel tube columns: Experiments and predictions
    Parsa-Sharif, Mohammad
    Nematzadeh, Mahdi
    Bahrami, Amirreza
    STRUCTURES, 2023, 51 : 1414 - 1437
  • [3] Push-out test of square CFST columns with steel plate shear connectors
    Qiao Q.
    Zhang W.
    Cao W.
    Dong H.
    2018, Huazhong University of Science and Technology (46): : 108 - 115
  • [4] PUSH-OUT TESTS
    BLACK, J
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1989, 23 (11): : 1243 - 1245
  • [5] Push-out tests of CFST columns strengthened with self-compacting and self-stressing concrete filled square steel tube
    School of Civil Engineering, Wuhan University, Wuhan
    430072, China
    J. Constr. Steel Res.,
  • [6] Push-out tests of CFST columns strengthened with self-compacting and self-stressing concrete filled square steel tube
    Huang, Yue
    Zhao, Pengtuan
    Lu, Yiyan
    Zhang, Hong
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 193
  • [7] Mechanic Model of Push-Out Test of Over-Thick CFST
    Gao Jinhe
    Huang Yanbin
    Zhang Shoulong
    APPLIED SCIENCE, MATERIALS SCIENCE AND INFORMATION TECHNOLOGIES IN INDUSTRY, 2014, 513-517 : 314 - 318
  • [8] Methodological considerations on push-out tests in Endodontics
    De-Deus, G.
    Souza, E.
    Versiani, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2015, 48 (05) : 501 - 503
  • [9] Evaluation of results from push-out tests
    Kvocak, V.
    Dubecky, D.
    ADVANCES AND TRENDS IN ENGINEERING SCIENCES AND TECHNOLOGIES, 2016, : 99 - 104
  • [10] The effect of push-out of perimeter building columns on their survival in fire
    Cai, J
    Burgess, I
    Plank, R
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON STEEL STRUCTURES OF THE 2000'S, 2000, : 345 - 350