A biometric investigation of ocular components in amblyopia

被引:29
作者
Cass, Kevin [1 ]
Tromans, Cindy [1 ]
机构
[1] Manchester Royal Eye Hosp, Dept Optometry, Manchester M13 9WH, Lancs, England
关键词
amblyopia; anisometropic; A-scan; paediatric; strabismic; ultrasound;
D O I
10.1111/j.1475-1313.2008.00585.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The aim of this study was to investigate the ocular parameters and their contribution to total axial length, and any inter-ocular differences when compared to the fellow non-amblyopic eye, in a population of paediatric amblyopes. Inter-ocular differences in visual acuity, refractive error, corneal curvature, anterior chamber depth and their contribution to total axial length were analysed in four populations: adult controls (n = 26), paediatric controls (n = 24), paediatric strabismic amblyopes (n = 18) and paediatric anisometropic amblyopes (n = 27). In the two control groups, there were small inter-ocular differences between the components, none of which were statistically or clinically significant. Anisometropic amblyopic eyes were found to have statistically and clinically significant differences in refractive error, crystalline lens power, vitreous chamber depth and total axial length when compared to the fellow eye. Anterior and vitreous chamber depths, when expressed as a percentage of the anterior and vitreous chambers in the non-amblyopic fellow eye, were approximately 95% of the size. When parameters were normalised by expressing as a percentage of total axial length, the contribution of the anterior chamber, crystalline lens and vitreous chamber to total axial length in both eyes were comparable, suggesting that all components of the anisometropic amblyopic eye are proportionately reduced in size. The strabismic amblyopic eyes were in the main isometropic. There were however statistically significant differences in anterior chamber depth, crystalline lens power, vitreous chamber depth and total axial length, but not in crystalline lens thickness. When the components were expressed as a percentage of the component in the non-amblyopic fellow eye, the anterior and vitreous chambers were approximately 90% of the size of the fellow non-amblyopic eye and made a significantly smaller contribution to total axial length when normalised. Crystalline lens thickness contributed significantly more to the total axial length in a strabismic eye. This suggests that, unlike control eyes or anisometropic amblyopic eyes, the strabismic eye is physically, though not proportionately, reduced in size.
引用
收藏
页码:429 / 440
页数:12
相关论文
共 43 条
[21]   Suppression Mapping in Amblyopia. An investigation into the gradient and depth of suppression [J].
Bobier, William ;
Babu, Raiju ;
Clavagnier, Simon ;
Thompson, Benjamin .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
[22]   The ocular biometric and corneal topographic characteristics of high-anisometropic adults in Taiwan [J].
Kuo, Ni-Wen ;
Shen, Chia-Jung ;
Sheu, Shwu-Jivan .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2011, 74 (07) :310-315
[23]   Amblyopia and peri-ocular capillary hemangioma of infancy: screening and prossession before and after surgery [J].
Momtchilova, M ;
Pelosse, B ;
Diner, PA ;
Vazquez, MP ;
Laroche, L .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2004, 27 (10) :1135-1140
[24]   Development of a core outcome set for amblyopia, strabismus and ocular motility disorders: a review to identify outcome measures [J].
Samia Al Jabri ;
Jamie Kirkham ;
Fiona J. Rowe .
BMC Ophthalmology, 19
[25]   Pattern of ocular dominance columns and cytochrome oxidase activity in a macaque monkey with naturally occurring anisometropic amblyopia [J].
Horton, JC ;
Hocking, DR ;
Kiorpes, L .
VISUAL NEUROSCIENCE, 1997, 14 (04) :681-689
[26]   Multifaceted Interactions of Stereoacuity, Inter-Ocular Suppression, and Fixation Eye Movement Abnormalities in Amblyopia and Strabismus [J].
Cakir, Gokce Busra ;
Murray, Jordan ;
Dulaney, Cody ;
Ghasia, Fatema .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (03)
[27]   Development of a core outcome set for amblyopia, strabismus and ocular motility disorders: a review to identify outcome measures [J].
Al Jabri, Samia ;
Kirkham, Jamie ;
Rowe, Fiona J. .
BMC OPHTHALMOLOGY, 2019, 19 (1)
[28]   The Effect of Font Size on Reading Performance in Strabismic Amblyopia: An Eye Movement Investigation [J].
Kanonidou, Evgenia ;
Gottlob, Irene ;
Proudlock, Frank A. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (01) :451-459
[29]   Concurrent Investigation of Global Motion and Form Processing in Amblyopia: An Equivalent Noise Approach [J].
Joshi, Mahesh R. ;
Simmers, Anita J. ;
Jeon, Seong T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (11) :5015-5022
[30]   Enriched experience and recovery from amblyopia in adult rats: Impact of motor, social and sensory components [J].
Baroncelli, Laura ;
Bonaccorsi, Joyce ;
Milanese, Marco ;
Bonifacino, Tiziana ;
Giribaldi, Francesco ;
Manno, Ilaria ;
Cenni, Maria Cristina ;
Berardi, Nicoletta ;
Bonanno, Giambattista ;
Maffei, Lamberto ;
Sale, Alessandro .
NEUROPHARMACOLOGY, 2012, 62 (07) :2388-2397