Heartbeat and Respiration Detection From Optical Interferometric Signals by Using a Multimethod Approach

被引:42
作者
Sprager, Sebastijan [1 ]
Zazula, Damjan [1 ]
机构
[1] Univ Maribor, Fac Elect Engn & Comp Sci, SI-2000 Maribor, Slovenia
关键词
Heartbeat detection; multimethod approach; optical interferometer; respiration detection; unobtrusive monitoring of vital functions; SENSORS;
D O I
10.1109/TBME.2012.2213302
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper, a multimethod approach for heartbeat and respiration detection from an optical interferometric signal is proposed. Optical interferometer is a sensitive device that detects physical changes of optical-fiber length due to external perturbations. When in direct or indirect contact with human body (e. g., hidden in a bed mattress), mechanical and acoustic activity of cardiac muscle and respiration reflect in the interferometric signal, enabling entirely unobtrusive monitoring of heartbeat and respiration. A novel, two-phased multimethod approach was developed for this purpose. The first phase selects best performing combinations of detection methods on a training set of signals. The second phase applies the selected methods to test set of signals and fuses all the detections of vital signs. The test set consisted of 14 subjects cycling an ergometer until reaching their submaximal heart rate. The following resting periods were analyzed showing high efficiency (98.18 +/- 1.40% sensitivity and 97.04 +/- 4.95% precision) and accuracy (mean absolute error of beat-to-beat intervals 22 +/- 9 ms) for heartbeat detection, and acceptable efficiency (90.06 +/- 7.49% sensitivity and 94.21 +/- 3.70% precision) and accuracy (mean absolute error of intervals between respiration events 0.33 +/- 0.14 s) for respiration detection.
引用
收藏
页码:2922 / 2929
页数:8
相关论文
共 22 条
[1]  
Ahlstrom C., 2006, Processing of the phonocardiographic signal: Methods for the intelligent stethoscope
[2]   Adaptive Beat-to-Beat Heart Rate Estimation in Ballistocardiograms [J].
Brueser, Christoph ;
Stadlthanner, Kurt ;
de Waele, Stijn ;
Leonhardt, Steffen .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2011, 15 (05) :778-786
[3]  
Cromwell L., 1980, BIOMEDICAL INSTRUMEN, V2nd
[4]  
JensenUrstad K, 1997, SCAND J MED SCI SPOR, V7, P274
[5]   An Electromechanical Film Sensor Based Wireless Ballistocardiographic Chair: Implementation and Performance [J].
Junnila, Sakari ;
Akhbardeh, Alireza ;
Varri, Alpo .
JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2009, 57 (03) :305-320
[6]  
Kokkinos P., 2008, PHYS ACTIVITY CARDIO
[7]   Heart sound segmentation algorithm based on heart sound envelogram [J].
Liang, H ;
Lukkarinen, S ;
Hartimo, I .
COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 :105-108
[8]   Biomedical sensors using optical fibres [J].
Mignani, AG ;
Baldini, F .
REPORTS ON PROGRESS IN PHYSICS, 1996, 59 (01) :1-28
[9]   Remote Sensing of Heart Rate and Patterns of Respiration on a Stationary Subject Using 94-GHz Millimeter-Wave Interferometry [J].
Mikhelson, Ilya V. ;
Bakhtiari, Sasan ;
Elmer, Thomas W., II ;
Sahakian, Alan V. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (06) :1671-1677
[10]   A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236