Pulsatile control of rotary blood pumps: Does the modulation waveform matter?

被引:58
作者
Pirbodaghi, Tohid [1 ]
Axiak, Shannon [2 ]
Weber, Alberto [3 ]
Gempp, Thomas [4 ]
Vandenberghe, Stijn [1 ]
机构
[1] Univ Bern, ARTORG Cardiovasc Engn, Bern, Switzerland
[2] Univ Bern, Dept Vet Anesthesia, Bern, Switzerland
[3] Univ Hosp Bern, Inselspital, Dept Cardiac Surg, CH-3010 Bern, Switzerland
[4] Levitronix GmbH, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
VENTRICULAR ASSIST DEVICE; CARDIOPULMONARY BYPASS; SUPPORT; FLOW; NONPULSATILE; PERFUSION; RECOVERY; FAILURE;
D O I
10.1016/j.jtcvs.2012.02.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Mechanical support of a failing heart is typically performed with rotary blood pumps running at constant speed, which results in a limited control on cardiac workload and nonpulsatile hemodynamics. A potential solution to overcome these limitations is to modulate the pump speed to create pulses. This study aims at developing a pulsatile control algorithm for rotary pumps, while investigating its effect on left ventricle unloading and the hemodynamics. Methods: The CentriMag (Levitronix GmbH, Zurich, Switzerland) rotary blood pump was implanted in 5 sheep and cannulated from the ventricular apex to the descending aorta. A modified controller was connected to the pump yielding direct speed control via analog voltage. Pump speed modulation patterns, including sine, saw tooth, triangle, and square waveforms with 2 different phase shifts, were synchronized with heartbeat. Various hemodynamic parameters, such as left ventricular pressure and volume, coronary flow, and arterial pressure, were analyzed to examine the influence of pump support. Results: The pump speed modulation significantly affected left ventricular pressure and volume and arterial pressure, whereas coronary flow was not influenced by pump support mode. Stroke work in the pulsatile modes varied from 69% to 91% of baseline value and from 74% to 96% of constant speed value. Consequently, cardiac workload can be adjusted to provide relaxation, which may lead to myocardial recovery. Conclusions: A synchronized pulsing rotary blood pump offers a simple and powerful control modality for heart unloading. This technique provides pulsatile hemodynamics, which is more physiologic than continuous blood flow and may be useful for perfusion of the other organs. (J Thorac Cardiovasc Surg 2012; 144: 970-7)
引用
收藏
页码:970 / 977
页数:8
相关论文
共 50 条
[21]   Physiologic and hematologic concerns of rotary blood pumps: what needs to be improved? [J].
Pirbodaghi, Tohid ;
Asgari, Siavash ;
Cotter, Chris ;
Bourque, Kevin .
HEART FAILURE REVIEWS, 2014, 19 (02) :259-266
[22]   Influence of Rotary Blood Pumps over Preload Recruitable Stroke Work [J].
Sugai, Telma Keiko ;
Tanaka, Akira ;
Yoshizawa, Makoto ;
Shiraishi, Yasuyuki ;
Baba, Atsushi ;
Yambe, Tomoyuki ;
Nitta, Shin-ichi .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :2367-2370
[23]   Fault Detection in Rotary Blood Pumps Using Motor Speed Response [J].
Soucy, Kevin G. ;
Koenig, Steven C. ;
Sobieski, Michael A. ;
Slaughter, Mark S. ;
Giridharan, Guruprasad A. .
ASAIO JOURNAL, 2013, 59 (04) :410-419
[24]   Compact Maglev Motor with Full DOF Active Control for Miniaturized Rotary Blood Pumps [J].
Osa, M. ;
Masuzawa, T. ;
Orihara, R. ;
Tatsumi, E. .
2017 11TH INTERNATIONAL SYMPOSIUM ON LINEAR DRIVES FOR INDUSTRY APPLICATIONS (LDIA), 2017,
[25]   Sensor-Based Physiologic Control Strategy for Biventricular Support with Rotary Blood Pumps [J].
Wang, Yu ;
Koenig, Steven C. ;
Wu, Zhongjun ;
Slaughter, Mark S. ;
Giridharan, Guruprasad A. .
ASAIO JOURNAL, 2018, 64 (03) :338-350
[26]   Feasible Approach to Control the Operation of Implantable Rotary Blood Pumps for Heart Failure Patients [J].
Bakouri, Mohsen A. ;
Savkin, Andrey V. ;
Alomari, Abdul-Hakeem H. ;
Salamonsen, Robert F. ;
Lim, Einly ;
Lovell, Nigel H. .
2013 9TH ASIAN CONTROL CONFERENCE (ASCC), 2013,
[27]   Physiological Control Law for Rotary Blood Pumps with Full-State Feedback Method [J].
Bakouri, Mohsen .
APPLIED SCIENCES-BASEL, 2019, 9 (21)
[28]   Electrodynamics of Axial-Flow Rotary Blood Pumps [J].
Nesterenko, Igor, V ;
Pugovkin, Alexander A. ;
Leonhardt, Steffen ;
Walter, Marian ;
Borchers, Patrick ;
Markov, Aleksandr ;
Karimov, Jamshid H. ;
Selishchev, Sergey, V ;
Telyshev, Dmitry, V .
IEEE ACCESS, 2021, 9 (09) :164700-164711
[29]   Speed Modulation of the HeartWare HVAD to Assess In Vitro Hemocompatibility of Pulsatile and Continuous Flow Regimes in a Rotary Blood Pump [J].
Horobin, Jarod T. ;
Simmonds, Michael J. ;
Nandakumar, Deepika ;
Gregory, Shaun D. ;
Tansley, Geoff ;
Pauls, Jo P. ;
Girnghuber, Angela ;
Balletti, Nicoletta ;
Fraser, John F. .
ARTIFICIAL ORGANS, 2018, 42 (09) :879-890
[30]   In Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop [J].
Cysyk, Joshua ;
Jhun, Choon-Sik ;
Newswanger, Ray ;
Pae, Walter ;
Izer, Jenelle ;
Flory, Heidi ;
Reibson, John ;
Weiss, William ;
Rosenberg, Gerson .
ASAIO JOURNAL, 2022, 68 (06) :791-799