Patient radiation exposure during transcatheter aortic valve replacement procedures

被引:26
作者
Daneault, Benoit [1 ,2 ]
Balter, Stephen [1 ]
Kodali, Susheel K. [1 ,2 ]
Williams, Mathew R. [1 ,2 ]
Genereux, Philippe [1 ,2 ]
Reiss, George R. [1 ]
Paradis, Jean-Michel [1 ,2 ]
Green, Philip [1 ]
Kirtane, Ajay J. [1 ,2 ]
Smith, Craig [1 ,2 ]
Moses, Jeffrey W. [1 ]
Leon, Martin B. [1 ,2 ]
机构
[1] Columbia Univ, Med Ctr, New York Presbyterian Hosp, New York, NY 10032 USA
[2] Cardiovasc Res Fdn, New York, NY USA
关键词
aortic stenosis; radiation; TAVR; GUIDED INTERVENTIONAL PROCEDURES; COREVALVE REVALVING SYSTEM; HIGH-RISK PATIENTS; IMPLANTATION; STENOSIS; OUTCOMES; REGISTRY; CARDIOLOGY; RADIOLOGY; SAFETY;
D O I
10.4244/EIJV8I6A106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: To describe patient radiation utilisation during transcatheter aortic valve replacement (TAVR) on a series of consecutive patients. Methods and results: Data on radiation exposure were prospectively collected for consecutive patients undergoing TAVR and percutaneous coronary interventions at our centre. Radiation dose during the procedure was recorded using the US Food and Drug Administration (FDA) reference point (K-a,K-r) and the dose area product (P-KA). In addition to quantifying overall radiation doses during TAVR, radiation exposure during transfemoral (TF) (n=79) and transapical (TA) (n=26) cases was compared. The median radiation dose during TAVR was 1,639 mGy (983-2,420), or 188(106-321) Gy*cm(2). Radiation dose was significantly lower among TA patients using either the reference point (TA: 946 [777-1,261] vs. TF: 1,932 [1,383-2,614] mGy; p<0.001) or the dose area product (TA: 89 [60-115] vs. TF: 236 [164-338] Gy*cm(2); p<0.001). Fluoroscopy time was lower for TA patients (TA: 10 [8-11] vs. TF: 30 [24-34] minutes; p<0.001). Operators experience did not affect radiation exposure for TF cases. Conclusions: Radiation exposure during TAVR appears similar to other percutaneous coronary interventions of moderate complexity. Radiation doses were significantly lower for TA procedures. A higher dose of radiation in TF patients may be related to additional imaging requirements to optimise percutaneous vascular access and closure.
引用
收藏
页码:679 / 684
页数:6
相关论文
共 27 条
[1]   Usefulness of TEE as the Primary Imaging Technique to Guide Transcatheter Transapical Aortic Valve Implantation [J].
Bagur, Rodrigo ;
Rodes-Cabau, Josep ;
Doyle, Daniel ;
De Larochelliere, Robert ;
Villeneuve, Jacques ;
Lemieux, Jerome ;
Bergeron, Sebastien ;
Cote, Melanie ;
Bertrand, Olivier F. ;
Pibarot, Philippe ;
Dumont, Eric .
JACC-CARDIOVASCULAR IMAGING, 2011, 4 (02) :115-124
[2]   Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients' Skin and Hair [J].
Balter, Stephen ;
Hopewell, John W. ;
Miller, Donald L. ;
Wagner, Louis K. ;
Zelefsky, Michael J. .
RADIOLOGY, 2010, 254 (02) :326-341
[3]   Radiation Safety Program for the Cardiac Catheterization Laboratory [J].
Chambers, Charles E. ;
Fetterly, Kenneth A. ;
Holzer, Ralf ;
Lin, Pei-Jan Paul ;
Blankenship, James C. ;
Balter, Stephen ;
Laskey, Warren K. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (04) :546-556
[4]   Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry [J].
Eltchaninoff, Helene ;
Prat, Alain ;
Gilard, Martine ;
Leguerrier, Alain ;
Blanchard, Didier ;
Fournial, Gerard ;
Iung, Bernard ;
Donzeau-Gouge, Patrick ;
Tribouilloy, Christophe ;
Debrux, Jean-Louis ;
Pavie, Alain ;
Gueret, Pascal .
EUROPEAN HEART JOURNAL, 2011, 32 (02) :191-197
[5]   Outcomes After Transcatheter Aortic Valve Implantation: Transfemoral Versus Transapical Approach [J].
Ewe, See Hooi ;
Delgado, Victoria ;
Ng, Arnold C. T. ;
Antoni, M. Louisa ;
van der Kley, Frank ;
Marsan, Nina Ajmone ;
de Weger, Arend ;
Tavilla, Giuseppe ;
Holman, Eduard R. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
ANNALS OF THORACIC SURGERY, 2011, 92 (04) :1244-1251
[6]   Clinical Determinants of Radiation Dose in Percutaneous Coronary Interventional Procedures [J].
Fetterly, Kenneth A. ;
Lennon, Ryan J. ;
Bell, Malcolm R. ;
Holmes, David R., Jr. ;
Rihal, Charanjit S. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) :336-343
[7]   Clinical Outcomes Using a New Crossover Balloon Occlusion Technique for Percutaneous Closure After Transfemoral Aortic Valve Implantation [J].
Genereux, Philippe ;
Kodali, Susheel ;
Leon, Martin B. ;
Smith, Craig R. ;
Ben-Gal, Yanai ;
Kirtane, Ajay J. ;
Daneault, Benoit ;
Reiss, George R. ;
Moses, Jeffrey W. ;
Williams, Mathew R. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (08) :861-867
[8]   Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System [J].
Grube, Eberhard ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Sauren, Barthel ;
Zickmann, Bernfried ;
Nair, Dinesh ;
Beucher, Harald ;
Felderhoff, Thomas ;
Iversen, Stein ;
Gerckens, Ulrich .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (03) :167-175
[9]   Results of Transfemoral or Transapical Aortic Valve Implantation Following a Uniform Assessment in High-Risk Patients With Aortic Stenosis [J].
Himbert, Dominique ;
Descoutures, Fleur ;
Al-Attar, Nawwar ;
Iung, Bernard ;
Ducrocq, Gregory ;
Detaint, Delphine ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Francis, Fady ;
Ibrahim, Hassan ;
Nataf, Patrick ;
Vahanian, Alec .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (04) :303-311
[10]   ACCF/AHA/HRS/SCAI clinical competence statement on physician knowledge to optimize patient safety and image quality in fluoroscopically guided invasive cardiovascular procedures - A report of the American College of Cardiology Foundation/American Heart Association/American College of Physicians Task Force on Clinical Competence and Training [J].
Hirshfeld, JW ;
Balter, S ;
Brinker, JA ;
Kern, MJ ;
Klein, LW ;
Lindsay, BD ;
Tommaso, CL ;
Tracy, CM ;
Wagner, LK ;
Creager, MA ;
Elnicki, M ;
Hirshfeld, JW ;
Lorell, BH ;
Rodgers, GP ;
Tracy, CM ;
Weitz, HH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (11) :2259-2282