Debonding resistance of FRP-to-clay brick masonry joints

被引:53
作者
Kashyap, J. [1 ]
Willis, C. R. [1 ]
Griffith, M. C. [1 ]
Ingham, J. M. [2 ]
Masia, M. J. [3 ]
机构
[1] Univ Adelaide, Sch Civil Environm & Min Engn, Adelaide, SA 5005, Australia
[2] Univ Auckland, Dept Civil & Environm Engn, Auckland 1, New Zealand
[3] Univ Newcastle, Ctr Infrastruct Performance & Reliabil, Fac Engn, Callaghan, NSW 2308, Australia
关键词
Masonry; FRP; Strengthening; Debonding; Bond pull-tests; Bond strength model; OF-PLANE LOADS; UNREINFORCED MASONRY; STRENGTH MODELS; CONCRETE JOINTS; BOND BEHAVIOR; WALLS; FAILURE; STRIPS; PLATES; BEAMS;
D O I
10.1016/j.engstruct.2012.03.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Debonding at the FRP-to-masonry interface has been identified as the preferred failure mechanism in fibre-reinforced polymer (FRP) retrofitted masonry as it allows for some redistribution of forces. The results of 14 FRP-to-masonry bond tests are presented, where the FRP was near surface mounted (NSM) to stack-bonded clay brick masonry. These tests were conducted to investigate the effect that variables such as cyclic loading and FRP strip dimensions have on the debonding resistance of a NSM FRP-to-masonry joint. These results were then incorporated into a large database of FRP retrofitted masonry pull test results by various researchers over the past 10 years. The database includes results for both externally bonded (EB) and NSM retrofitting techniques. From this database, local bond-slip parameters such as the maximum interface shear stress, tau(max), and the maximum slip, delta(max), were investigated to determine correlations between these values and masonry material properties. Further, 15 existing concrete and masonry bond strength (maximum load at the FRP-to-substrate interface) models in the literature were assessed for their use with masonry by Comparing these models against the results in the pull test database. Based on the comparative statistics of the test-to-predicted bond strength it is concluded that a new FRP-to-masonry bond model is required which gives more accurate predictions. Results include a discussion on the global load-slip response and FRP-to-masonry interface behaviour. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:186 / 198
页数:13
相关论文
共 52 条
[1]   Strengthening of unreinforced masonry walls using FRPs [J].
Albert, ML ;
Elwi, AE ;
Cheng, JJR .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2001, 5 (02) :76-84
[2]  
[Anonymous], 2007, DOBOKU GAKKAI RONBUN
[3]  
AS (Australian Standard), 2001, Committee BD-004. Masonry structures
[4]  
Blaschko M, 2003, FIBRE-REINFORCEMENT POLYMER: REINFORCEMENT FOR CONCRETE STRUCTURES, VOLS 1 AND 2, PROCEEDINGS, P205
[5]  
Brozens K., 1999, P FRPRCS 4 SP 188 56, P635
[6]   Experimental FRP/SRP-historic masonry delamination [J].
Capozucca, Roberto .
COMPOSITE STRUCTURES, 2010, 92 (04) :891-903
[7]   Investigation of the Interface Fracture during Debonding between FRP and Masonry [J].
Carloni, Christian ;
Subramaniam, Kolluru V. .
ADVANCES IN STRUCTURAL ENGINEERING, 2009, 12 (05) :731-743
[8]   Strengthening of reinforced concrete beams with externally bonded fiber-reinforced-plastic plates: design guidelines for shear and flexure [J].
Chaallal, O ;
Nollet, MJ ;
Perraton, D .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1998, 25 (04) :692-704
[9]   Debonding failure along a softening FRP-to-concrete interface between two adjacent cracks in concrete members [J].
Chen, J. F. ;
Yuan, H. ;
Teng, J. G. .
ENGINEERING STRUCTURES, 2007, 29 (02) :259-270
[10]   Anchorage strength models for FRP and steel plates bonded to concrete [J].
Chen, JF ;
Teng, JG .