A novel approach to eliminate detection of contaminating Staphylococcal species introduced during clinical testing

被引:3
作者
Ao, Wanyuan [1 ]
Clifford, Adrianne [1 ]
Corpuz, Maylene [1 ]
Jenison, Robert [1 ]
机构
[1] Great Basin Corp, Salt Lake City, UT 84111 USA
关键词
COAGULASE-NEGATIVE STAPHYLOCOCCI; REAL-TIME-PCR; BLOOD CULTURE; MOLECULAR METHODS; BACTERIAL; INTERVENTION; MISMATCHES; SAMPLES; AUREUS; REDUCE;
D O I
10.1371/journal.pone.0171915
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We describe here a strategy that can distinguish between Staphylococcus species truly present in a clinical sample from contaminating Staphylococcus species introduced during the testing process. Contaminating Staphylococcus species are present at low levels in PCR reagents and colonize lab personnel. To eliminate detection of contaminants, we describe an approach that utilizes addition of sufficient quantities of either non-target Staphylococcal cells (Staphylococcus succinus or Staphylococcus muscae) or synthetic oligonucleotide templates to helicase dependent isothermal amplification reactions to consume Staphylococcus-specific tuf and mecA gene primers such that contaminating Staphylococcus amplification is suppressed to below assay limits of detection. The suppressor template DNA is designed with perfect homology to the primers used in the assay but an internal sequence that is unrelated to the Staphylococcal species targeted for detection. Input amount of the suppressor is determined by a mathematical model described herein and is demonstrated to completely suppress contaminating levels of Staphylococcus while not negatively impacting the appropriate clinical assay limit of detection. We have applied this approach to improve the specificity of detection of Staphylococcus species present in positive blood cultures using a chip-based array that produces results visible to the unaided eye.
引用
收藏
页数:15
相关论文
共 27 条
[1]   Nurses' competency in drawing blood cultures and educational intervention to reduce the contamination rate [J].
Al-Hamad, Arif ;
Al-Ibrahim, Maha ;
Alhajhouj, Eman ;
Jaffer, Waseelah Al-Alshaikh ;
Altowaileb, Jaffar ;
Alfaraj, Hassan .
JOURNAL OF INFECTION AND PUBLIC HEALTH, 2016, 9 (01) :66-74
[2]  
Ao W, 2016, US Patent, Patent No. 9434999
[3]   Does nasal cocolonization by methicillin-resistant coagulase-negative Staphylococci and methicillin-susceptible Staphylococcus aureus strains occur frequently enough to represent a risk of false-positive methicillin-resistant S. aureus determinations by molecular methods? [J].
Becker, K ;
Pagnier, I ;
Schuhen, B ;
Wenzelburger, F ;
Friedrich, AW ;
Kipp, F ;
Peters, G ;
von Eiff, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (01) :229-231
[4]   Contamination and sensitivity issues with a real-time universal 16S rRNA PCR [J].
Corless, CE ;
Guiver, M ;
Borrow, R ;
Edwards-Jones, V ;
Kaczmarski, EB ;
Fox, AJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) :1747-1752
[5]   RNase H-dependent PCR (rhPCR): improved specificity and single nucleotide polymorphism detection using blocked cleavable primers [J].
Dobosy, Joseph R. ;
Rose, Scott D. ;
Beltz, Kristin R. ;
Rupp, Susan M. ;
Powers, Kristy M. ;
Behlke, Mark A. ;
Walder, Joseph A. .
BMC BIOTECHNOLOGY, 2011, 11
[6]   Blood collection procedures influence contamination rates in blood culture: a prospective study [J].
Ge Ying ;
Liu Xiao-qing ;
Xu Ying-chun ;
Xu Shan ;
Yu Min-hong ;
Zhang Wei ;
Deng Guo-hua .
CHINESE MEDICAL JOURNAL, 2011, 124 (23) :4002-4006
[7]   Topographical and Temporal Diversity of the Human Skin Microbiome [J].
Grice, Elizabeth A. ;
Kong, Heidi H. ;
Conlan, Sean ;
Deming, Clayton B. ;
Davis, Joie ;
Young, Alice C. ;
Bouffard, Gerard G. ;
Blakesley, Robert W. ;
Murray, Patrick R. ;
Green, Eric D. ;
Turner, Maria L. ;
Segre, Julia A. .
SCIENCE, 2009, 324 (5931) :1190-1192
[8]   Automated Detection of Toxigenic Clostridium difficile in Clinical Samples: Isothermal tcdB Amplification Coupled to Array-Based Detection [J].
Hicke, Brian ;
Pasko, Chris ;
Groves, Benjamin ;
Ager, Edward ;
Corpuz, Maylene ;
Frech, Georges ;
Munns, Denton ;
Smith, Wendy ;
Warcup, Ashley ;
Denys, Gerald ;
Ledeboer, Nathan A. ;
Lindsey, Wes ;
Owen, Charles ;
Rea, Larry ;
Jenison, Robert .
JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (08) :2681-2687
[9]   Removal of Contaminant DNA by Combined UV-EMA Treatment Allows Low Copy Number Detection of Clinically Relevant Bacteria Using Pan-Bacterial Real-Time PCR [J].
Humphrey, Bruce ;
McLeod, Neil ;
Turner, Carrie ;
Sutton, J. Mark ;
Dark, Paul M. ;
Warhurst, Geoffrey .
PLOS ONE, 2015, 10 (07)
[10]   Microbial contamination of hematopoietic progenitor and other regenerative cells used in transplantation and regenerative medicine [J].
Jacobs, Michael R. ;
Good, Caryn E. ;
Fox, Robert M. ;
Roman, Katharine P. ;
Lazarus, Hillard M. .
TRANSFUSION, 2013, 53 (11) :2690-2696