Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography

被引:48
|
作者
Hubanova, Ralitsa [1 ,2 ]
Aptel, Florent [1 ,2 ,3 ]
Chiquet, Christophe [1 ,2 ,3 ]
Mottet, Benjamin [1 ,2 ]
Romanet, Jean-Paul [1 ,2 ]
机构
[1] UJF Grenoble 1, Grenoble, France
[2] CHU Grenoble, Dept Ophthalmol, F-38043 Grenoble, France
[3] Univ Grenoble 1, INSERM, U1042, Lab Hypoxia & Physiopathol, Grenoble, France
关键词
corneal thickness; optical coherence tomography; contact lens sensor; intraocular pressure; CONTACT-LENS; TOPOGRAPHICAL THICKNESS; EPITHELIUM; EYE;
D O I
10.1111/aos.12241
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the effect of overnight wear of the Triggerfish((R)) contact lens sensor (CLS) on central corneal thickness (CCT) using the Visante((R)) anterior segment optical coherence tomography (AS-OCT). Methods Twelve healthy subjects were studied in a sleep laboratory. An ophthalmic examination including ultrasonic CCT, corneal topography, specular microscopy and AS-OCT CCT was performed. Starting at 7pm, the Triggerfish((R)) CLS was fitted on one randomly selected eye. Similar AS-OCT measurements were taken on both eyes every 2hr from 8pm to 8am. The CLS was removed just after the 8am measurement session. Measurements were repeated at 9am. Results Twenty-four eyes of 12 subjects were studied (mean age, 22.1 +/- 2.4years; four men/eight women). CCT significantly increased during the night in both CLS and control eyes (p<0.01). The maximal change was +4.4 +/- 1.7% in the CLS eyes and +2.9 +/- 1.8% in the control eyes (p<0.05). Throughout the night, CCT significantly increased more in eyes with CLS than in control eyes (p<0.05). There were significantly more corneal curvature irregularities after overnight wear of the CLS than in the control eye: +1.63Dioptre (D) versus -0.02D in the 3-mm central zone and +3.17D versus +0.01D in the 5-mm central zone (p<0.01). Conclusion CCT and corneal curvature irregularities increased slightly but significantly more in eyes with the Triggerfish((R)) CLS than in control eyes during overnight wear. Further studies are required to determine whether the corneal curvature changes modify the signal recorded by the sensor.
引用
收藏
页码:E119 / E123
页数:5
相关论文
共 50 条
  • [41] Polarization sensitive corneal and anterior segment swept-source optical coherence tomography
    Lim, Yiheng
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPHTHALMIC TECHNOLOGIES XX, 2010, 7550
  • [42] Corneal thickness after overnight wear of an intraocular pressure fluctuation contact lens sensor
    Freiberg, Florentina J.
    Lindell, Jeanette
    Thederan, Luisa A-L
    Leippi, Swetlana
    Shen, Yanan
    Klink, Thomas
    ACTA OPHTHALMOLOGICA, 2012, 90 (07) : E534 - E539
  • [43] Anterior and posterior segment parameters measured with Fourier domain optical coherence tomography in photopic and scotopic conditions
    Rampersad, Nishanee
    Hansraj, Rekha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (02) : 136 - 139
  • [44] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Carlo Bruttini
    Roberto Esposti
    Alfredo Pece
    Giulio Maione
    Paolo Cavallari
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1857 - 1863
  • [45] Impact of pterygium on central corneal thickness measured by optical coherence tomography in older adults
    Dotto, Pedro Gabriel
    Salomao, Solange Rios
    Fernandes, Arthur Gustavo
    Mitsuhiro, Marcia Regina Kimie Higashi
    Ferraz, Nivea Nunes
    Furtado, Joao Marcello
    Watanabe, Sung Song
    Cypel, Marcela
    Sacai, Paula Yuri
    Cunha, Cristina Coimbra
    Vasconcelos, Galton Carvalho
    Morales, Paulo Henrique
    Cohen, Marcos Jacob
    Cohen, Jacob Moyses
    Campos, Mauro
    Munoz, Sergio
    Belfort Jr, Rubens
    Berezovsky, Adriana
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (04) : 1583 - 1588
  • [46] Corneal layer thickness in keratoconus using optical coherence tomography
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Hajizadeh, Fedra
    Fotouhi, Akbar
    Hashemi, Hassan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (01) : 32 - 39
  • [47] Automatic segmentation of anterior segment optical coherence tomography images
    Williams, Dominic
    Zheng, Yalin
    Bao, Fangjun
    Elsheikh, Ahmed
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
  • [48] Central Corneal Thickness Among Filipino Patients in an Ambulatory Eye Surgery Center Using Anterior Segment Optical Coherence Tomography
    Sosuan, George Michael N.
    Yap-Veloso, Maria Imelda R.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2653 - 2664
  • [49] Comparison of Central Corneal Thickness and Anterior Chamber Depth Measured Using LenStar LS900, Pentacam, and Visante AS-OCT
    O'Donnell, Clare
    Hartwig, Andreas
    Radhakrishnan, Hema
    CORNEA, 2012, 31 (09) : 983 - 988
  • [50] Anterior segment optical coherence tomography in acute anterior uveitis
    Agra, Cristiana
    Agra, Lydianne
    Dantas, Jeanine
    Faria e Arantes, Tiago Eugenio
    de Andrade Neto, Joao Lins
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2014, 77 (01) : 1 - 3