Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography

被引:48
|
作者
Hubanova, Ralitsa [1 ,2 ]
Aptel, Florent [1 ,2 ,3 ]
Chiquet, Christophe [1 ,2 ,3 ]
Mottet, Benjamin [1 ,2 ]
Romanet, Jean-Paul [1 ,2 ]
机构
[1] UJF Grenoble 1, Grenoble, France
[2] CHU Grenoble, Dept Ophthalmol, F-38043 Grenoble, France
[3] Univ Grenoble 1, INSERM, U1042, Lab Hypoxia & Physiopathol, Grenoble, France
关键词
corneal thickness; optical coherence tomography; contact lens sensor; intraocular pressure; CONTACT-LENS; TOPOGRAPHICAL THICKNESS; EPITHELIUM; EYE;
D O I
10.1111/aos.12241
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the effect of overnight wear of the Triggerfish((R)) contact lens sensor (CLS) on central corneal thickness (CCT) using the Visante((R)) anterior segment optical coherence tomography (AS-OCT). Methods Twelve healthy subjects were studied in a sleep laboratory. An ophthalmic examination including ultrasonic CCT, corneal topography, specular microscopy and AS-OCT CCT was performed. Starting at 7pm, the Triggerfish((R)) CLS was fitted on one randomly selected eye. Similar AS-OCT measurements were taken on both eyes every 2hr from 8pm to 8am. The CLS was removed just after the 8am measurement session. Measurements were repeated at 9am. Results Twenty-four eyes of 12 subjects were studied (mean age, 22.1 +/- 2.4years; four men/eight women). CCT significantly increased during the night in both CLS and control eyes (p<0.01). The maximal change was +4.4 +/- 1.7% in the CLS eyes and +2.9 +/- 1.8% in the control eyes (p<0.05). Throughout the night, CCT significantly increased more in eyes with CLS than in control eyes (p<0.05). There were significantly more corneal curvature irregularities after overnight wear of the CLS than in the control eye: +1.63Dioptre (D) versus -0.02D in the 3-mm central zone and +3.17D versus +0.01D in the 5-mm central zone (p<0.01). Conclusion CCT and corneal curvature irregularities increased slightly but significantly more in eyes with the Triggerfish((R)) CLS than in control eyes during overnight wear. Further studies are required to determine whether the corneal curvature changes modify the signal recorded by the sensor.
引用
收藏
页码:E119 / E123
页数:5
相关论文
共 50 条
  • [31] Effects of age on ocular anterior segment dimensions measured by optical coherence tomography
    Qin Bing
    Zhou Xing-tao
    Huang, David
    Chu Ren-yuan
    CHINESE MEDICAL JOURNAL, 2011, 124 (12) : 1829 - 1834
  • [32] Mean central corneal thickness and corneal power measurements in pigmented and white rabbits using Visante optical coherence tomography and ATLAS corneal topography
    Wang, Xiaogang
    Dong, Jing
    Wu, Qiang
    VETERINARY OPHTHALMOLOGY, 2014, 17 (02) : 87 - 90
  • [33] Comparative study of anterior segment measurement with Pentacam and anterior segment optical coherence tomography
    Fu, Jing
    Wang, Xiaozhen
    Li, Shuning
    Wu, Gewei
    Wang, Ningli
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2010, 45 (06): : 627 - 631
  • [34] Normal corneal thickness measurements in pigmented rabbits using spectral-domain anterior segment optical coherence tomography
    Wang, Xiaogang
    Wu, Qiang
    VETERINARY OPHTHALMOLOGY, 2013, 16 (02) : 130 - 134
  • [35] Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Coherence Tomography
    Wasielica-Poslednik, Joanna
    Lisch, Walter
    Bell, Katharina
    Weyer, Veronika
    Pfeiffer, Norbert
    Gericke, Adrian
    CORNEA, 2016, 35 (03) : 342 - 349
  • [36] Quantitative anterior segment optical coherence tomography
    Ortiz, Sergio
    Marcos, Susana
    OPTICA PURA Y APLICADA, 2014, 47 (03): : 227 - 238
  • [37] The Value of Anterior Segment Optical Coherence Tomography in Different Types of Corneal Infections: An Update
    Abdelghany, Ahmed A.
    D'Oria, Francesco
    Del Barrio, Jorge Alio
    Alio, Jorge L.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (13)
  • [38] Optical coherence tomography in anterior segment imaging
    Kalev-Landoy, Maya
    Day, Alexander C.
    Cordeiro, M. Francesca
    Migdal, Clive
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (04): : 427 - 430
  • [39] Practical Applications of Anterior Segment Optical Coherence Tomography Imaging Following Corneal Surgery
    Sayegh, Rony R.
    Pineda, Roberto, II
    SEMINARS IN OPHTHALMOLOGY, 2012, 27 (5-6) : 125 - 132
  • [40] Corneal hysteresis and anterior segment optical coherence tomography anatomical parameters in primary angle closure suspects
    Hussnain, Syed Amal
    Kovacs, Kyle D.
    Warren, Joshua L.
    Teng, Christopher C.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (05) : 468 - 472