Effect of overnight wear of the Triggerfish® sensor on corneal thickness measured by Visante® anterior segment optical coherence tomography

被引:48
|
作者
Hubanova, Ralitsa [1 ,2 ]
Aptel, Florent [1 ,2 ,3 ]
Chiquet, Christophe [1 ,2 ,3 ]
Mottet, Benjamin [1 ,2 ]
Romanet, Jean-Paul [1 ,2 ]
机构
[1] UJF Grenoble 1, Grenoble, France
[2] CHU Grenoble, Dept Ophthalmol, F-38043 Grenoble, France
[3] Univ Grenoble 1, INSERM, U1042, Lab Hypoxia & Physiopathol, Grenoble, France
关键词
corneal thickness; optical coherence tomography; contact lens sensor; intraocular pressure; CONTACT-LENS; TOPOGRAPHICAL THICKNESS; EPITHELIUM; EYE;
D O I
10.1111/aos.12241
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To evaluate the effect of overnight wear of the Triggerfish((R)) contact lens sensor (CLS) on central corneal thickness (CCT) using the Visante((R)) anterior segment optical coherence tomography (AS-OCT). Methods Twelve healthy subjects were studied in a sleep laboratory. An ophthalmic examination including ultrasonic CCT, corneal topography, specular microscopy and AS-OCT CCT was performed. Starting at 7pm, the Triggerfish((R)) CLS was fitted on one randomly selected eye. Similar AS-OCT measurements were taken on both eyes every 2hr from 8pm to 8am. The CLS was removed just after the 8am measurement session. Measurements were repeated at 9am. Results Twenty-four eyes of 12 subjects were studied (mean age, 22.1 +/- 2.4years; four men/eight women). CCT significantly increased during the night in both CLS and control eyes (p<0.01). The maximal change was +4.4 +/- 1.7% in the CLS eyes and +2.9 +/- 1.8% in the control eyes (p<0.05). Throughout the night, CCT significantly increased more in eyes with CLS than in control eyes (p<0.05). There were significantly more corneal curvature irregularities after overnight wear of the CLS than in the control eye: +1.63Dioptre (D) versus -0.02D in the 3-mm central zone and +3.17D versus +0.01D in the 5-mm central zone (p<0.01). Conclusion CCT and corneal curvature irregularities increased slightly but significantly more in eyes with the Triggerfish((R)) CLS than in control eyes during overnight wear. Further studies are required to determine whether the corneal curvature changes modify the signal recorded by the sensor.
引用
收藏
页码:E119 / E123
页数:5
相关论文
共 50 条
  • [21] Investigation of the Sectorized Corneal Thickness of Eyes With Corneal Endothelial Dysfunction Using Anterior-Segment Optical Coherence Tomography
    Omoto, Takashi
    Kim, Minjae
    Goto, Hiroki
    Abe, Yuito
    Ono, Takashi
    Taketani, Yukako
    Toyono, Tetsuya
    Yoshida, Junko
    Usui, Tomohiko
    Yamagami, Satoru
    Aihara, Makoto
    Miyai, Takashi
    CORNEA, 2023, 42 (06) : 714 - 718
  • [22] Anterior segment optical coherence tomography
    Ang, Marcus
    Baskaran, Mani
    Werkmeister, Rene M.
    Chua, Jacqueline
    Schmidl, Doreen
    dos Santos, Valentin Aranha
    Garhoefer, Gerhard
    Mehta, Jodhbir S.
    Schmetterer, Leopold
    PROGRESS IN RETINAL AND EYE RESEARCH, 2018, 66 : 132 - 156
  • [23] Comparison of central corneal thickness measured by automatic and manual analysis of optical coherence tomography
    Bruttini, Carlo
    Esposti, Roberto
    Pece, Alfredo
    Maione, Giulio
    Cavallari, Paolo
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (06) : 1857 - 1863
  • [24] Anterior Segment Optical Coherence Tomography
    Jancevski, Maria
    Foster, C. Stephen
    SEMINARS IN OPHTHALMOLOGY, 2010, 25 (5-6) : 317 - 323
  • [25] Corneal thickness mapping by 3D swept-source anterior segment optical coherence tomography
    Neri, Alberto
    Malori, Marianna
    Scaroni, Patrizia
    Leaci, Rosachiara
    Delfini, Elisabetta
    Macaluso, Claudio
    ACTA OPHTHALMOLOGICA, 2012, 90 (06) : e452 - e457
  • [26] Relations Among Corneal Curvature, Thickness, and Volume in Keratoconus as Evaluated by Anterior Segment-Optical Coherence Tomography
    Morishige, Naoyuki
    Magome, Kazuyoshi
    Ueno, Akifumi
    Matsui, Taka-Aki
    Nishida, Teruo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (12) : 3794 - 3802
  • [27] Ultrahigh-resolution anterior segment optical coherence tomography for analysis of corneal microarchitecture during wound healing
    Pantalon, Anca
    Pfister, Martin
    dos Santos, Valentin Aranha
    Sapeta, Sabina
    Unterhuber, Angelika
    Pircher, Niklas
    Schmidinger, Gerald
    Garhoefer, Gerhard
    Schmidl, Doreen
    Schmetterer, Leopold
    Werkmeister, Rene M.
    ACTA OPHTHALMOLOGICA, 2019, 97 (05) : E761 - E771
  • [28] Age- and sex-related differences in corneal epithelial thickness measured with spectral domain anterior segment optical coherence tomography among Egyptians
    Samy, Magda Mahmoud
    Shaaban, Yasmine Maher
    Badran, Tamer Abdel Fattah
    MEDICINE, 2017, 96 (42)
  • [29] Corneal epithelial thickness measured by Fourier-domain optical coherence tomography
    Wang, Ting
    Li, Fengjie
    Wang, Shuting
    Shi, Weiyun
    SPEKTRUM DER AUGENHEILKUNDE, 2016, 30 (01) : 3 - 9
  • [30] Central and Midperipheral Corneal Thickness Measured with Scheimpflug Imaging and Optical Coherence Tomography
    Huang, Jinhai
    Ding, Xixia
    Savini, Giacomo
    Jiang, Zhengxuan
    Pan, Chao
    Hua, Yanjun
    Wu, Fan
    Feng, Yifan
    Yu, Ye
    Wang, Qinmei
    PLOS ONE, 2014, 9 (05):