Retrospective Study in 40 Patients of Utility of C-arm FDCT as an Adjunctive Modality in Technically Challenging Image-Guided Percutaneous Drainage Procedures

被引:1
作者
Rafiei, Poyan [1 ]
Kim, Seung Kwon [1 ]
Kamran, Mudassar [1 ]
Saad, Nael E. [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, Intervent Radiol, St Louis, MO 63110 USA
关键词
Non-vascular interventions; Catheter drainage; Abscess; CONE-BEAM CT; FLAT-PANEL-DETECTOR; INTERVENTIONAL RADIOLOGY; ANGIOGRAPHIC CT; EARLY EXPERIENCE; GUIDANCE; EMBOLIZATION; FEASIBILITY; FLUOROSCOPY; ACCURACY;
D O I
10.1007/s00270-015-1091-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore the utility of C-arm flat detector computed tomography (FDCT) as an adjunctive modality in technically challenging image-guided percutaneous drainage procedures. Clinical and image data were reviewed on 40 consecutive patients who underwent percutaneous drainage of fluid collections in technically challenging anatomic locations that required the use of C-arm FDCT between 2009 and 2013. Percutaneous drainage was performed under ultrasound and fluoroscopic guidance with the use of C-arm FDCT as a problem-solving tool to identify appropriate needle/wire placement prior to drainage catheter placement (n = 33) or to confirm catheter positioning within the fluid collection (n = 8). Technical success and procedural complications were recorded and retrospectively analyzed. Forty one fluid collections were identified in 40 patients. Mean number of C-arm FDCT rotational acquisitions per patient was 1.25. Mean procedure time per patient was 59.3 min. Mean fluoroscopy time was 5.5 min, and mean air kerma was 394.3 mGy. Percutaneous drainage with the use of C-arm FDCT was successful in 35 of 40 patients (87.5 %). Technical failure was encountered in 5 of 40 patients due to too narrow window (n = 1), too small or no fluid collection noted on C-arm FDCT images (n = 2), and poor image quality requiring the use of a conventional CT scan (n = 2). Three procedure-related complications occurred (7.5 %), which included traversed rectum, traversed spleen, and sepsis. C-arm FDCT is useful as an adjunctive modality in the interventional suite for technically challenging percutaneous drainage procedures by providing sufficient anatomic detail. Complications of catheter misplacement can be avoided if C-arm FDCT is used prior to tract dilatation. If C-arm FDCT image quality of needle and/or wire placement is poor, conventional CT guidance is recommended.
引用
收藏
页码:1589 / 1594
页数:6
相关论文
共 24 条
[11]  
Ikeda S, 2012, SHOW U J MED SCI, V24, P59
[12]   C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology [J].
Kamran, Mudassar ;
Nagaraja, Sanjoy ;
Byrne, James V. .
NEURORADIOLOGY, 2010, 52 (04) :319-327
[13]   Classifying complications of interventional procedures: A survey of practicing radiologists [J].
Leoni, CJ ;
Potter, JE ;
Rosen, MP ;
Brophy, DP ;
Lang, EV .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (01) :55-59
[14]   Contrast-enhanced abdominal angiographic CT for intra-abdominal tumor embolization: A new tool for vessel and soft tissue visualization [J].
Meyer, Bernhard Christian ;
Frericks, Bernd Benedikt ;
Albrecht, Thomas ;
Wolf, Karl-Juergen ;
Wacker, Frank Klaus .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 30 (04) :743-749
[15]   C-arm cone-beam CT: General principles and technical considerations for use in interventional radiology [J].
Orth, Robert C. ;
Wallace, Michael J. ;
Kuo, Michael D. .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (06) :814-820
[16]  
Powell MF, 2010, PAIN PHYSICIAN, V13, P51
[17]   Live 3D guidance in the interventional radiology suite [J].
Racadio, John M. ;
Babic, Drazenko ;
Homan, Robert ;
Rampton, John W. ;
Patel, Manish N. ;
Racadio, Judy M. ;
Johnson, Neil D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :W357-W364
[18]   Flat panel detector angiopaphic CT for Stent-Assisted coil embolization of broad-based cerebral aneurysms [J].
Richter, G. ;
Engelhorn, T. ;
Struffert, T. ;
Doelken, M. ;
Ganslandt, O. ;
Hornegger, J. ;
Kalender, W. A. ;
Doerfler, A. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (10) :1902-1908
[19]  
Sacks David, 2003, J Vasc Interv Radiol, V14, pS199
[20]   Volume CT with a flat-panel detector on a mobile, isocentric C-arm: Pre-clinical investigation in guidance of minimally invasive surgery [J].
Siewerdsen, JH ;
Moseley, DJ ;
Burch, S ;
Bisland, SK ;
Bogaards, A ;
Wilson, BC ;
Jaffray, DA .
MEDICAL PHYSICS, 2005, 32 (01) :241-254