Retrospective Study in 40 Patients of Utility of C-arm FDCT as an Adjunctive Modality in Technically Challenging Image-Guided Percutaneous Drainage Procedures

被引:1
作者
Rafiei, Poyan [1 ]
Kim, Seung Kwon [1 ]
Kamran, Mudassar [1 ]
Saad, Nael E. [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, Sch Med, Intervent Radiol, St Louis, MO 63110 USA
关键词
Non-vascular interventions; Catheter drainage; Abscess; CONE-BEAM CT; FLAT-PANEL-DETECTOR; INTERVENTIONAL RADIOLOGY; ANGIOGRAPHIC CT; EARLY EXPERIENCE; GUIDANCE; EMBOLIZATION; FEASIBILITY; FLUOROSCOPY; ACCURACY;
D O I
10.1007/s00270-015-1091-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To explore the utility of C-arm flat detector computed tomography (FDCT) as an adjunctive modality in technically challenging image-guided percutaneous drainage procedures. Clinical and image data were reviewed on 40 consecutive patients who underwent percutaneous drainage of fluid collections in technically challenging anatomic locations that required the use of C-arm FDCT between 2009 and 2013. Percutaneous drainage was performed under ultrasound and fluoroscopic guidance with the use of C-arm FDCT as a problem-solving tool to identify appropriate needle/wire placement prior to drainage catheter placement (n = 33) or to confirm catheter positioning within the fluid collection (n = 8). Technical success and procedural complications were recorded and retrospectively analyzed. Forty one fluid collections were identified in 40 patients. Mean number of C-arm FDCT rotational acquisitions per patient was 1.25. Mean procedure time per patient was 59.3 min. Mean fluoroscopy time was 5.5 min, and mean air kerma was 394.3 mGy. Percutaneous drainage with the use of C-arm FDCT was successful in 35 of 40 patients (87.5 %). Technical failure was encountered in 5 of 40 patients due to too narrow window (n = 1), too small or no fluid collection noted on C-arm FDCT images (n = 2), and poor image quality requiring the use of a conventional CT scan (n = 2). Three procedure-related complications occurred (7.5 %), which included traversed rectum, traversed spleen, and sepsis. C-arm FDCT is useful as an adjunctive modality in the interventional suite for technically challenging percutaneous drainage procedures by providing sufficient anatomic detail. Complications of catheter misplacement can be avoided if C-arm FDCT is used prior to tract dilatation. If C-arm FDCT image quality of needle and/or wire placement is poor, conventional CT guidance is recommended.
引用
收藏
页码:1589 / 1594
页数:6
相关论文
共 24 条
  • [1] Benndorf G, 2005, AM J NEURORADIOL, V26, P1813
  • [2] Translumbar type II endoleak repair using angiographic CT
    Binkert, Christoph A.
    Alencar, Herlen
    Singh, Jai
    Baum, Richard A.
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (08) : 1349 - 1353
  • [3] Real-Time 3D Fluoroscopy Guidance During Needle Interventions: Technique, Accuracy, and Feasibility
    Braak, S. J.
    van Strijen, M. J. L.
    van Leersum, M.
    van Es, H. W.
    van Heesewijk, J. P. M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : W445 - W451
  • [4] Flat-Panel Cone-Beam Ct-Guided Radiofrequency Ablation of Very Small (aparts per thousandcurrency sign1.5 cm) Liver Tumors: Technical Note on a Preliminary Experience
    Cazzato, Roberto Luigi
    Buy, Xavier
    Alberti, Nicolas
    Fonck, Mariane
    Grasso, Rosario Francesco
    Palussiere, Jean
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 38 (01) : 206 - 212
  • [5] Transthoracic needle biopsy using a C-arm cone-beam CT system: diagnostic accuracy and safety
    Choi, M. J.
    Kim, Y.
    Hong, Y. S.
    Shim, S. S.
    Lim, S. M.
    Lee, J. K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1014) : E182 - E187
  • [6] Feasibility of C-arm-supported CT fluoroscopy in percutaneous abscess drainage procedures
    Froelich, JJ
    El-Sheik, M
    Wagner, HJ
    Achenbach, S
    Scherf, C
    Klose, KJ
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 23 (06) : 423 - 430
  • [7] Adjunctive use of C-arm CT may eliminate technical failure in adrenal vein sampling
    Georgiades, Christos S.
    Hong, Kelvin
    Geschwind, Jean-Francois
    Liddell, Robert
    Syed, Labib
    Kharlip, Julia
    Arepally, Aravind
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (09) : 1102 - 1105
  • [8] Heran NS, 2006, AM J NEURORADIOL, V27, P330
  • [9] Cone-beam CT with flat-panel-detector digital angiography system: Early experience in abdominal interventional procedures
    Hirota, Shozo
    Nakao, Norio
    Yamamoto, Satoshi
    Kobayashi, Kaoru
    Maeda, Hiroaki
    Ishikura, Reiichi
    Miura, Koui
    Sakamoto, Kiyoshi
    Ueda, Ken
    Baba, Rika
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (06) : 1034 - 1038
  • [10] Percutaneous vertebroplasty: Preliminary experiences with rotational acquisitions and 3D reconstructions for therapy control
    Hodek-Wuerz, Roman
    Martin, Jean-Baptiste
    Wilhelm, Kai
    Lovblad, Karl O.
    Babic, Drazenko
    Rufenacht, Daniel A.
    Wetzel, Stefan G.
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (05) : 862 - 865