The intrastromal corneal ring segments - Phase II results for the correction of myopia

被引:133
作者
Schanzlin, DJ
Asbell, PA
Burris, TE
Durrie, DS
机构
[1] ST LOUIS UNIV,ANHEUSER BUSCH EYE INST,ST LOUIS,MO 63103
[2] MT SINAI SCH MED,NEW YORK,NY
[3] NW CORNEAL SERV,PORTLAND,OR
[4] HUNKELER EYE CTR PC,KANSAS CITY,MO
关键词
D O I
10.1016/S0161-6420(97)30183-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: The purpose of the study was to evaluate the safety and efficacy of the intrastromal corneal ring segments (ICRS) for the correction of myopia. Design: A 2-year phase II clinical trial of ICRS was initiated in May 1995. The investigational plan specifies that 150 patients with sighted eyes, requiring myopic corrections from -1.00 to -6.00 diopters (D), will each receive ICRS in 1 eye. The patient population will be divided into approximately five patients per ICRS thickness (0.25, 0.30, 0.35, 0.40, and 0.45 mm) per site. Six investigational sites are participating in the trial. Participants: Fifty-nine men and 43 women requiring myopic corrections were enrolled at four U.S. investigational sites. These 102 patients each received the ICRS product in 1 eye. Intervention: Correction of myopia. Main Outcome Measures: Efficacy of ICRS was assessed with respect to the trial endpoints of predictability of refractive effect, uncorrected visual acuity (UCVA), stability of UCVA, maintenance of best spectacle-corrected visual acuity and stability of refractive effect. Results: As shown by the available month-3 data (99 patients; all device thicknesses), 95 (96%) of 99 patients had a UCVA of 20/40 or better. Ninety-eight (99%) of 99 patients were within 2 lines of their preoperative best spectacle-corrected visual acuity. The average change (with standard error) in cycloplegic refraction (spherical equivalent) achieved by ICRS thickness was -1.27 +/- 0.09 D (0.25 mm), -2.13 +/- 0.16 D (0.30 mm), -2.56 +/- 0.15 D (0.35 mm), -3.77 +/- 0.37 D (0.40 mm) and -4.16 +/- 0.24 D (0.45 mm). Seventy-seven percent (76/99) of the patients were within +/-1.00 D of their intended correction. When the ICRS was removed in two cases, both patients returned to within 0.75 D of their preoperative manifest refraction. Conclusions: The ICRS appears to be a viable and effective alternative for the treatment of myopia. Additionally, as indicated by the explant data, the ICRS's refractive effect may be reversible upon removal of the device.
引用
收藏
页码:1067 / 1078
页数:12
相关论文
共 17 条
[1]   ONE-YEAR RESULTS OF THE INTRASTROMAL CORNEAL RING IN NONFUNCTIONAL HUMAN EYES [J].
ASSIL, KK ;
BARRETT, AM ;
FOURAKER, BD ;
SCHANZLIN, DJ .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (02) :159-167
[2]  
BARRAQUER JI, 1989, CORNEAL SURG, V5, P179
[3]  
Burris T E, 1991, Refract Corneal Surg, V7, P46
[4]   FLATTENING OF CENTRAL CORNEAL CURVATURE WITH INTRASTROMAL CORNEAL RINGS OF INCREASING THICKNESS - AN EYE-BANK EYE STUDY [J].
BURRIS, TE ;
BAKER, PC ;
AYER, CT ;
LOOMAS, BE ;
MATHIS, ML ;
SILVESTRINI, TA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 :182-187
[5]   CORNEAL SENSITIVITY AFTER PHOTOREFRACTIVE KERATECTOMY [J].
CAMPOS, M ;
HERTZOG, L ;
GARBUS, JJ ;
MCDONNELL, PJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1992, 114 (01) :51-54
[6]  
DURRIE DS, 1993, ATLAS CORNEAL TOPOGR, P125
[7]  
Fleming J F, 1989, CLAO J, V15, P146
[8]  
FLEMING JF, 1987, J REFRACT SURG, V3, P227
[9]  
ISHIKAWA T, 1994, J REFRACT CORNEAL S, V10, P417
[10]   CORNEAL SENSATION AFTER SMALL-INCISION, SUTURELESS, ONE-HANDED PHACOEMULSIFICATION [J].
JOHN, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (04) :425-428