Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

被引:40
作者
Blumhagen, Jan O. [1 ]
Braun, Harald [2 ]
Ladebeck, Ralf [1 ]
Fenchel, Matthias [1 ]
Faul, David [3 ]
Scheffler, Klaus [4 ,5 ]
Quick, Harald H. [2 ]
机构
[1] Siemens AG, Healthcare Sect, Magnet Resonance, D-91052 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[3] Siemens Med Solut, New York, NY 10015 USA
[4] Max Planck Inst Biol Cybernet, MRC Dept, D-72076 Tubingen, Germany
[5] Univ Tubingen Hosp, Dept Biomed Magnet Resonance, D-72076 Tubingen, Germany
关键词
MR/PET; attenuation correction; FoV truncation; distortion correction; FoV extension; GEOMETRIC DISTORTION; HYBRID PET/MRI; QUANTIFICATION; RECONSTRUCTION; PET/CT;
D O I
10.1118/1.4861097
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B-0) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B0 inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the computation time by obviating the need for iterative calculations of the PET emission data beyond those required for reconstructing images. (C) 2014 American Association of Physicists in Medicine.
引用
收藏
页数:9
相关论文
共 33 条
[1]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[2]   Characterization, prediction, and correction of geometric distortion in 3 T MR images [J].
Baldwin, Lesley N. ;
Wachowicz, Keith ;
Thomas, Steven D. ;
Rivest, Ryan ;
Fallone, B. Gino .
MEDICAL PHYSICS, 2007, 34 (02) :388-399
[3]   Switching on the Lights for Real-Time Multimodality Tumor Neuroimaging: The Integrated Positron-Emission Tomography/MR Imaging System [J].
Bisdas, S. ;
Naegele, T. ;
Schlemmer, H. -P. ;
Boss, A. ;
Claussen, C. D. ;
Pichler, B. ;
Ernemann, U. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (04) :610-614
[4]  
Blumhagen J. O., 2011, P 28 ANN M ESMRMB LE, P604
[5]   MR-Based Field-of-View Extension in MR/PET: B0 Homogenization Using Gradient Enhancement (HUGE) [J].
Blumhagen, Jan O. ;
Ladebeck, Ralf ;
Fenchel, Matthias ;
Scheffler, Klaus .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (04) :1047-1057
[6]  
Blumhagen JOLR, 2012, P 20 ANN M 20 ISMRM, V20, P2720
[7]   Standards for PET Image Acquisition and Quantitative Data Analysis [J].
Boellaard, Ronald .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 :11S-20S
[8]   Hybrid PET/MRI of Intracranial Masses: Initial Experiences and Comparison to PET/CT [J].
Boss, Andreas ;
Bisdas, Sotirios ;
Kolb, Armin ;
Hofmann, Matthias ;
Ernemann, Ulrike ;
Claussen, Claus D. ;
Pfannenberg, Christina ;
Pichler, Bernd J. ;
Reimold, Matthias ;
Stegger, Lars .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (08) :1198-1205
[9]   Diffusion Tensor Imaging in a Human PET/MR Hybrid System [J].
Boss, Andreas ;
Kolb, Armin ;
Hofmann, Matthias ;
Bisdas, Sotirios ;
Naegele, Thomas ;
Ernemann, Ulrike ;
Stegger, Lars ;
Rossi, Cristina ;
Schlemmer, Heinz-Peter ;
Pfannenberg, Christina ;
Reimold, Matthias ;
Claussen, Claus D. ;
Pichler, Bernd J. ;
Klose, Uwe .
INVESTIGATIVE RADIOLOGY, 2010, 45 (05) :270-274
[10]   Imaging prostate cancer: An update on positron emission tomography and magnetic resonance imaging [J].
Bouchelouche K. ;
Turkbey B. ;
Choyke P. ;
Capala J. .
Current Urology Reports, 2010, 11 (3) :180-190