Cine MR Fourier velocimetry of blood flow through cardiac valves: Comparison with Doppler echocardiography

被引:31
作者
Mohiaddin, RH
Gatehouse, PD
Henien, M
Firmin, DN
机构
[1] Magnetic Resonance Unit, Department of Cardiology, Royal Brompton Hospital, London, SW3 6HP, Sydney Street
关键词
MRI; cardiac; valves; flow;
D O I
10.1002/jmri.1880070408
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noninvasive measurement of blood flow velocity through the cardiac valves has important clinical applications. A wide variety of MR methods are available for now measurement. The aim of this study was to investigate the ability of cine MR Fourier velocimetry to measure now through healthy cardiac valves and to compare MR and Doppler peak velocity measurements. Ten healthy volunteers (age mean +/- SD, 24 +/- 4 years) without history of valvular disease were studied. Four of the subjects were females, In each subject, aortic, pulmonary, mitral, and tricuspid valves were evaluated with MR and Doppler imaging, A whole-body mobile MR machine was used, operating at .5-T with actively shielded magnetic field gradient coils on all three axes capable of 20 mT/m at a slew rate of 60 mT/m/msec, The heart rate during MR and Doppler studies was not significantly different, The mean difference between the two studies was 2 beats/min, with a 95% confidence interval of -22 beats/min, +25 beats/min. Peak systolic flow velocity in the aortic and pulmonary valves and peak diastolic how velocity in the mitral and tricuspid valves measured with MRI and Doppler echocardiography correlated well, The mean difference between the two measurements (MR - Doppler) was 63 mm/sec, with a 95% confidence interval of -180 mm/sec, +310 mm/sec. The agreement between two observers interpreting the same MR velocity maps was close, The mean difference between their two measurements was 23 mm/sec, with a 95% confidence interval of -20 mm/sec, +60 mm/sec, There was no significant difference between MR and Doppler imaging or between the two MR observers, MR Fourier velocimetry has the necessary ease, reliability, and speed to measure blood flow through the cardiac valves, although measurement of late diastolic now in the atrioventricular valves is limited. Measurement of peak blood velocity through the cardiac valves by this method showed satisfactory agreement with Doppler, but its clinical application for assessing diseased cardiac valves must be established.
引用
收藏
页码:657 / 663
页数:7
相关论文
共 26 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[3]  
CRELIER GR, 1995, P 3 ANN M SOC MAG RE, P1027
[4]   QUANTITATIVE MEASUREMENT OF BLOOD-FLOW USING CYLINDRICALLY LOCALIZED FOURIER VELOCITY ENCODING [J].
DUMOULIN, CL ;
SOUZA, SP ;
HARDY, CJ ;
ASH, SA .
MAGNETIC RESONANCE IN MEDICINE, 1991, 21 (02) :242-250
[5]   QUANTITATIVE MEASUREMENT OF VELOCITY AT MULTIPLE POSITIONS USING COMB EXCITATION AND FOURIER VELOCITY ENCODING [J].
DUMOULIN, CL ;
DOORLY, DJ ;
CARO, CG .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (01) :44-52
[6]   MAGNETIC-RESONANCE-IMAGING THE VELOCITY VECTOR COMPONENTS OF FLUID-FLOW [J].
FEINBERG, DA ;
CROOKS, LE ;
SHELDON, P ;
HOENNINGER, J ;
WATTS, J ;
ARAKAWA, M .
MAGNETIC RESONANCE IN MEDICINE, 1985, 2 (06) :555-566
[7]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[8]  
FIRMIN DN, 1993, MAGNETIC RESONANCE A, P187
[9]  
GATEHOUSE PD, 1995, P 3 SCI M SOC MAGN R, P568
[10]  
GATEHOUSE PD, 1995, P 3 ANN M SOC MAGN R, P318