Feasibility and diagnostic accuracy of an electronic nose in children with asthma and cystic fibrosis

被引:44
|
作者
Bannier, Michiel A. G. E. [1 ]
van de Kant, Kim D. G. [1 ]
Jobsis, Quirijn [1 ]
Dompeling, Edward [1 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Publ Hlth & Primary Care CAPHRI, Dept Paediat Resp Med, Maastricht, Netherlands
关键词
asthma; cystic fibrosis; electronic nose; exhaled breath; volatile organic compounds; children; VOLATILE ORGANIC-COMPOUNDS; DISCRIMINATION;
D O I
10.1088/1752-7163/aae158
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of volatile organic compounds (VOCs) in exhaled breath is a promising tool for diagnosing and monitoring various lung diseases in children. Gas chromatography mass spectrometry (GC-MS) analysis is a frequently used standard technique for VOCs analysis. However, as GC-MS is an expensive and time-consuming technique, hand-held devices or electronic noses have been developed. Recently, the Aeonose was introduced as an easy-to-use hand-held eNose capable of pointof-care testing. Although first results using this eNose in adults are promising, studies in children are lacking. We therefore performed a cross-sectional study in 55 children and adolescents >= 6 years of age (20 children with moderate to severe asthma, 13 children with CF, and 22 healthy controls). The feasibility of the Aeonose was high (>98% successful measurements). The diagnostic accuracy was high for discriminating asthma from CF (Area Under the Receiver Operating Characteristic Curve [AUC] 0.90 [95% Confidence Interval 0.78-1.00] sensitivity 89% [65%-98%], specificity 77% [46%94%]), and for the distinction between CF and healthy controls (AUC 0.87 [0.74-1.00], sensitivity 85% [54%-97%], specificity 77% [54%-91%]). However, the diagnostic accuracy for the discrimination between asthma and healthy controls was modest (AUC 0.79 [0.63-0.94], sensitivity 74% [49%90%], specificity 91% [69%-98%]). This is the first study to report test results of the Aeonose in children and adolescents 6 years. This eNose showed a high feasibility with modest to good diagnostic accuracies in asthma and CF.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Electronic Nose Breathprints Are Independent of Acute Changes in Airway Caliber in Asthma
    Lazar, Zsofia
    Fens, Niki
    van der Maten, Jan
    van der Schee, Marc P.
    Wagener, Ariane H.
    de Nijs, Selma B.
    Dijkers, Erica
    Sterk, Peter J.
    SENSORS, 2010, 10 (10): : 9127 - 9138
  • [22] Interrupter technique versus plethysmography for measurement of respiratory resistance in children with asthma or cystic fibrosis
    Oswald-Mammosser, M
    Charloux, A
    Donato, L
    Albrech, C
    Speich, JP
    Lampert, E
    Lonsdorfer, J
    PEDIATRIC PULMONOLOGY, 2000, 29 (03) : 213 - 220
  • [23] Exhaled carbon monoxide is not flow dependent in children with cystic fibrosis and asthma
    Beck-Ripp, J
    Latzin, P
    Griese, M
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2004, 9 (11) : 518 - 522
  • [24] Cystic fibrosis, atopy, asthma and ABPA
    Antunes, J.
    Fernandes, A.
    Miguel Borrego, L.
    Leiria-Pinto, P.
    Cavaco, J.
    ALLERGOLOGIA ET IMMUNOPATHOLOGIA, 2010, 38 (05) : 278 - 284
  • [25] Macrolides in the treatment of asthma and cystic fibrosis
    Ferrara, G
    Losi, M
    Franco, F
    Corbetta, L
    Fabbri, LM
    Richeldi, L
    RESPIRATORY MEDICINE, 2005, 99 (01) : 1 - 10
  • [26] Asthma and Cystic Fibrosis: A Tangled Web
    Kent, Brian D.
    Lane, Stephen J.
    van Beek, Edwin J.
    Dodd, Jonathan D.
    Costello, Richard W.
    Tiddens, Harm A. W. M.
    PEDIATRIC PULMONOLOGY, 2014, 49 (03) : 205 - 213
  • [27] Non-Invasive Diagnostic Approaches for Kidney Disease: The Role of Electronic Nose Systems
    Sansone, Francesco
    Tonacci, Alessandro
    SENSORS, 2024, 24 (19)
  • [28] Energy balance and the accuracy of reported energy intake in preadolescent children with cystic fibrosis
    Trabulsi, Jillian
    Schall, Joan I.
    Ittenbach, Richard F.
    Olsen, Irene E.
    Yudkoff, Marc
    Daikhin, Yevgeny
    Zemel, Babette S.
    Stallings, Virginia A.
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2006, 84 (03) : 523 - 530
  • [29] Breath Analysis by Electronic Nose for Asthma detection
    Shelat, Saumya J.
    Patel, H. K.
    Desai, M. D.
    3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE 2012), 2012,
  • [30] Identification and prospective stability of electronic nose (eNose)-derived inflammatory phenotypes in patients with severe asthma
    Brinkman, Paul
    Wagener, Ariane H.
    Hekking, Pieter-Paul
    Bansal, Aruna T.
    Maitland-van der Zee, Anke-Hilse
    Wang, Yuanyue
    Weda, Hans
    Knobel, Hugo H.
    Vink, Teunis J.
    Rattray, Nicholas J.
    D'Amico, Arnaldo
    Pennazza, Giorgio
    Santonico, Marco
    Lefaudeux, Diane
    De Meulder, Bertrand
    Auffray, Charles
    Bakke, Per S.
    Caruso, Massimo
    Chanez, Pascal
    Chung, Kian F.
    Corfield, Julie
    Dahlen, Sven-Erik
    Djukanovic, Ratko
    Geiser, Thomas
    Horvath, Ildiko
    Krug, Nobert
    Musial, Jacek
    Sun, Kai
    Riley, John H.
    Shaw, Dominic E.
    Sandstrom, Thomas
    Sousa, Ana R.
    Montuschi, Paolo
    Fowler, Stephen J.
    Sterk, Peter J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2019, 143 (05) : 1811 - +