Feasibility and diagnostic accuracy of an electronic nose in children with asthma and cystic fibrosis

被引:44
|
作者
Bannier, Michiel A. G. E. [1 ]
van de Kant, Kim D. G. [1 ]
Jobsis, Quirijn [1 ]
Dompeling, Edward [1 ]
机构
[1] Maastricht Univ, Med Ctr, Sch Publ Hlth & Primary Care CAPHRI, Dept Paediat Resp Med, Maastricht, Netherlands
关键词
asthma; cystic fibrosis; electronic nose; exhaled breath; volatile organic compounds; children; VOLATILE ORGANIC-COMPOUNDS; DISCRIMINATION;
D O I
10.1088/1752-7163/aae158
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of volatile organic compounds (VOCs) in exhaled breath is a promising tool for diagnosing and monitoring various lung diseases in children. Gas chromatography mass spectrometry (GC-MS) analysis is a frequently used standard technique for VOCs analysis. However, as GC-MS is an expensive and time-consuming technique, hand-held devices or electronic noses have been developed. Recently, the Aeonose was introduced as an easy-to-use hand-held eNose capable of pointof-care testing. Although first results using this eNose in adults are promising, studies in children are lacking. We therefore performed a cross-sectional study in 55 children and adolescents >= 6 years of age (20 children with moderate to severe asthma, 13 children with CF, and 22 healthy controls). The feasibility of the Aeonose was high (>98% successful measurements). The diagnostic accuracy was high for discriminating asthma from CF (Area Under the Receiver Operating Characteristic Curve [AUC] 0.90 [95% Confidence Interval 0.78-1.00] sensitivity 89% [65%-98%], specificity 77% [46%94%]), and for the distinction between CF and healthy controls (AUC 0.87 [0.74-1.00], sensitivity 85% [54%-97%], specificity 77% [54%-91%]). However, the diagnostic accuracy for the discrimination between asthma and healthy controls was modest (AUC 0.79 [0.63-0.94], sensitivity 74% [49%90%], specificity 91% [69%-98%]). This is the first study to report test results of the Aeonose in children and adolescents 6 years. This eNose showed a high feasibility with modest to good diagnostic accuracies in asthma and CF.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Electronic nose in discrimination of children with uncontrolled asthma
    Tenero, Laura
    Sandri, Marco
    Piazza, Michele
    Paiola, Giulia
    Zaffanello, Marco
    Piacentini, Giorgio
    JOURNAL OF BREATH RESEARCH, 2020, 14 (04)
  • [2] Exhaled breath profiling using broadband quantum cascade laser-based spectroscopy in healthy children and children with asthma and cystic fibrosis
    Mastrigt, Evan
    Reyes-Reyes, A.
    Brand, K.
    Bhattacharya, N.
    Urbach, H. P.
    Stubbs, A. P.
    de Jongste, J. C.
    Pijnenburg, M. W.
    JOURNAL OF BREATH RESEARCH, 2016, 10 (02)
  • [3] Diagnostic accuracy of oropharyngeal cultures in infants and young children with cystic fibrosis
    Rosenfeld, M
    Emerson, J
    Accurso, F
    Armstrong, D
    Castile, R
    Grimwood, K
    Hiatt, P
    McCoy, K
    McNamara, S
    Ramsey, B
    Wagener, J
    PEDIATRIC PULMONOLOGY, 1999, 28 (05) : 321 - 328
  • [4] Diagnostic accuracy of breath tests for pneumoconiosis using an electronic nose
    Yang, Hsiao-Yu
    Peng, Hsin-Yi
    Chang, Che-Jui
    Chen, Pau-Chung
    JOURNAL OF BREATH RESEARCH, 2018, 12 (01)
  • [5] An electronic nose in the discrimination of patients with asthma and controls
    Dragonieri, Silvano
    Schot, Robert
    Mertens, Bart J. A.
    Le Cessie, Saskia
    Gauw, Stefanie A.
    Spanevello, Antonio
    Resta, Onofrio
    Willard, Nico P.
    Vink, Teunis J.
    Rabe, Klaus F.
    Bel, Elisabeth H.
    Sterk, Peter J.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 120 (04) : 856 - 862
  • [6] Inflammatory Asthma Phenotype Discrimination Using an Electronic Nose Breath Analyzer
    Plaza, V
    Crespo, A.
    Giner, J.
    Merino, J. L.
    Ramos-Barbon, D.
    Mateus, E. F.
    Torrego, A.
    Cosio, B. G.
    Agusti, A.
    Sibila, O.
    JOURNAL OF INVESTIGATIONAL ALLERGOLOGY AND CLINICAL IMMUNOLOGY, 2015, 25 (06) : 431 - 437
  • [7] Increased airway smooth muscle mass in children with asthma, cystic fibrosis, and non-cystic fibrosis bronchiectasis
    Regamey, Nicolas
    Ochs, Matthias
    Hilliard, Tom N.
    Muehlfeld, Christian
    Cornish, Nikki
    Fleming, Louise
    Saglani, Seial
    Alton, Eric W. F. W.
    Bush, Andrew
    Jeffery, Peter K.
    Davies, Jane C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2008, 177 (08) : 837 - 843
  • [8] Association between individual sensor behavior of an electronic nose and airways inflammation in children with asthma: a pilot study at alpine altitude climate
    Ferrante, Giuliana
    Cogo, Anna Luisa
    Sandri, Marco
    Piazza, Michele
    Costella, Silvia
    Appodia, Massimiliano
    Aralla, Raffaele
    Tenero, Laura
    Zaffanello, Marco
    Piacentini, Giorgio
    PEDIATRIC PULMONOLOGY, 2024, 59 (05) : 1339 - 1345
  • [9] Effect of transportation and storage using sorbent tubes of exhaled breath samples on diagnostic accuracy of electronic nose analysis
    van der Schee, M. P.
    Fens, N.
    Brinkman, P.
    Bos, L. D. J.
    Angelo, M. D.
    Nijsen, T. M. E.
    Raabe, R.
    Knobel, H. H.
    Vink, T. J.
    Sterk, P. J.
    JOURNAL OF BREATH RESEARCH, 2013, 7 (01)
  • [10] Perception of Pulmonary Function in Children with Asthma and Cystic Fibrosis
    Forno, Erick
    Abraham, Neethu
    Winger, Daniel G.
    Rosas-Salazar, Christian
    Kurland, Geoffrey
    Weiner, Daniel J.
    PEDIATRIC ALLERGY IMMUNOLOGY AND PULMONOLOGY, 2018, 31 (03) : 139 - 145