Comparison of the NucliSENS EasyQ HIV-1 v2.0 with Abbott m2000rt RealTime HIV-1 assay for plasma RNA quantitation in different HIV-1 subtypes

被引:10
|
作者
Gomes, Perpetua [1 ,2 ,3 ]
Carvalho, Ana Patricia [1 ]
Diogo, Isabel [1 ]
Goncalves, Fatima [1 ]
Costa, Ines [1 ]
Cabanas, Joaquim [1 ]
Camacho, Ricardo Jorge [1 ,3 ]
机构
[1] Hosp Egas Moniz, Ctr Hosp Lisboa Ocidental, Mol Biol Lab, Serv Med Transfus, P-1349019 Lisbon, Portugal
[2] Inst Super Ciencias Saude Egas Moniz, Ctr Invest Interdisciplinar Egas Moniz, Monte De Caparica, Portugal
[3] Univ Nova Lisboa, Inst Higiene & Med Trop, Ctr Malaria & Outras Doencas Tropicais, P-1200 Lisbon, Portugal
关键词
HIV-1; EasyQ HIV-1; m2000; Subtypes; AMPLIPREP/COBAS TAQMAN HIV-1; NON-B SUBTYPES; VIRAL LOAD ASSAYS; VIRUS; RECOMBINANT; PERFORMANCE; INFECTION; CHINA; PANEL; V1.2;
D O I
10.1016/j.jviromet.2013.05.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Quantitation of HIV-1 RNA levels in plasma has significant prognostic value since high viral load concentrations in plasma are associated with a faster disease progression. Viral load testing became one the most important tools for monitoring HIV patients. New real time methodologies to quantify HIV viral load had arisen in the last decade. HIV is a virus with a high genetic variability, with the potential to negatively affect the performance of the viral load assays. Consequently, any new assay should be challenged against, at least, the most prevalent HIV-1 genetic variants. In the present study, the new version of NucliSENS EasyQ (R) HIV-1 (Version 2.0) quantitative assay was compared with another ultra-sensitive test - Abbott RealTime HIV-1 - using 175 plasma samples from patients infected with several HIV-1 subtypes and recombinant forms: subtype B (41, 23%), subtype C (19, 11%), subtype G (76, 44%), and CRF02_AG (39, 22%). Overall, there was agreement between the assays in 95.43% of the samples. Both assays have a very good dynamic range [1.4-6.9] and [1.60-7.0] log(10) copies/mL and excellent correlation in samples with various subtypes. Based on the fact that no clinically significant differences were observed in the viral load measurements by these two assays, HIV-1 subtypes are quantified equally by both assays. However due to HIV diversity, mainly in regions were non B subtypes are predominant more evaluations are needed, so we do not recommend to switch platform during longitudinal viral load monitoring. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [1] Comparison of the bioMerieux NucliSENS EasyQ HIV-1 v2.0-HIV-1 RNA quantification assay versus Abbott RealTime HIV-1 and Roche Cobas TaqMan HIV-1 v2.0 on current epidemic HIV-1 variants
    Mourez, Thomas
    Delaugerre, Constance
    Vray, Muriel
    Lemee, Veronique
    Simon, Francois
    Plantier, Jean-Christophe
    JOURNAL OF CLINICAL VIROLOGY, 2015, 71 : 76 - 81
  • [2] HIV-1 RNA quantification in plasma specimens using nuclisens easyQ HIV-1 V2.0
    Oosterlaken, T.
    van Deursen, P.
    Jurriaans, S.
    Ligeon, V.
    Bertens, L.
    de Jong, J.
    JOURNAL OF CLINICAL VIROLOGY, 2009, 46 : S27 - S27
  • [3] Evaluation of the NucliSens EasyQ HIV-1 v1.1 and RealTime HIV-1 kits for quantitation of HIV-1 RNA in plasma
    Choi, Ju-yeon
    Kim, Eun-Jin
    Rho, Hyun Joo
    Kim, Jin Young
    Kwon, Oh-Kyung
    Lee, Jin-Hee
    Koo, Min Jee
    Kim, Sung Soon
    JOURNAL OF VIROLOGICAL METHODS, 2009, 161 (01) : 7 - 11
  • [4] Evaluation of the RealTime HIV-1, Xpert HIV-1, and Aptima HIV-1 Quant Dx Assays in Comparison to the NucliSens EasyQ HIV-1 v2.0 Assay for Quantification of HIV-1 Viral Load
    Mor, Orna
    Gozlan, Yael
    Wax, Marina
    Mileguir, Fernando
    Rakovsky, Avia
    Noy, Bina
    Mendelson, Ella
    Levy, Itzchak
    JOURNAL OF CLINICAL MICROBIOLOGY, 2015, 53 (11) : 3458 - 3465
  • [5] Quantitative detection of HIV-1 RNA using NucliSens EasyQ HIV-1 assay
    Yao, J
    Liu, Z
    Ko, LS
    Pan, G
    Jiang, Y
    JOURNAL OF VIROLOGICAL METHODS, 2005, 129 (01) : 40 - 46
  • [6] Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma
    de Mendoza, C
    Koppelman, M
    Montès, B
    Ferre, V
    Soriano, V
    Cuypers, H
    Segondy, M
    Oosterlaken, T
    JOURNAL OF VIROLOGICAL METHODS, 2005, 127 (01) : 54 - 59
  • [7] Quantitation of HIV-1 RNA in dried blood spots by the real-time NucliSENS EasyQ HIV-1 assay in Senegal
    Kane, Coumba Toure
    Ndiaye, Halimatou Diop
    Diallo, Sada
    Ndiaye, Ibrahima
    Wade, Abdoulaye Sidibe
    Diaw, Papa Alassane
    Gaye-Diallo, Aissatou
    Mboup, Souleymane
    JOURNAL OF VIROLOGICAL METHODS, 2008, 148 (1-2) : 291 - 295
  • [8] Evaluation of the Aptima® HIV-1 Quant Dx Assay for HIV-1 RNA Viral Load Detection and Quantitation in Plasma of HIV-1-Infected Individuals: A Comparison With Abbott RealTime HIV-1 Assay
    Amendola, Alessandra
    Pisciotta, Maria
    Aleo, Loredana
    Ferraioli, Valeria
    Angeletti, Claudio
    Capobianchi, Maria Rosaria
    JOURNAL OF MEDICAL VIROLOGY, 2016, 88 (09) : 1535 - 1544
  • [9] Evaluation of the NucliSens EasyQ v2.0 Assay in Comparison with the Roche Amplicor v1.5 and the Roche CAP/CTM HIV-1 Test v2.0 in Quantification of C-Clade HIV-1 in Plasma
    Muenchhoff, Maximilian
    Madurai, Savathee
    Hempenstall, Allison Jo
    Adland, Emily
    Carlqvist, Anna
    Moonsamy, Angeline
    Jaggernath, Manjeetha
    Mlotshwa, Busisiwe
    Siboto, Emma
    Ndung'u, Thumbi
    Goulder, Philip Jeremy Renshaw
    PLOS ONE, 2014, 9 (08):
  • [10] Comparative evaluation of the Artus HIV-1 QS-RGQ assay and the Abbott RealTime HIV-1 assay for the quantification of HIV-1 RNA in plasma
    Garcia-Diaz, Ana
    Labbett, Wendy
    Clewley, Gillian S.
    Guerrero-Ramos, Alvaro
    Geretti, Anna Maria
    JOURNAL OF CLINICAL VIROLOGY, 2013, 57 (01) : 66 - 69