The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting

被引:6
作者
Yu, Yang [1 ]
Zhang, Fan [1 ]
Gao, Ming-Xin [1 ]
Li, Hai-Tao [1 ]
Li, Jing-Xing [1 ]
Song, Wei [1 ]
Huang, Xin-Sheng [1 ]
Gu, Cheng-Xiong [1 ]
机构
[1] Capital Med Univ, Beijing An Zhen Hosp, Dept Cardiac Surg, Beijing 100029, Peoples R China
关键词
Sequential saphenous coronary artery bypass grafting; Transit time flow measurement; Anastomotic quality; COMPUTED-TOMOGRAPHY; SELECTIVE ARTERIALIZATION; CORONARY; PUMP; PATENCY; SURGERY;
D O I
10.1093/icvts/ivt398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intraoperative transit time flow measurement (TTFM) is widely used to assess anastomotic quality in coronary artery bypass grafting (CABG). However, in sequential vein grafting, the flow characteristics collected by the conventional TTFM method are usually associated with total graft flow and might not accurately indicate the quality of every distal anastomosis in a sequential graft. The purpose of our study was to examine a new TTFM method that could assess the quality of each distal anastomosis in a sequential graft more reliably than the conventional TTFM approach. Two TTFM methods were tested in 84 patients who underwent sequential saphenous off-pump CABG in Beijing An Zhen Hospital between April and August 2012. In the conventional TTFM method, normal blood flow in the sequential graft was maintained during the measurement, and the flow probe was placed a few centimetres above the anastomosis to be evaluated. In the new method, blood flow in the sequential graft was temporarily reduced during the measurement by placing an atraumatic bulldog clamp at the graft a few centimetres distal to the anastomosis to be evaluated, while the position of the flow probe remained the same as in the conventional method. This new TTFM method was named the flow reduction TTFM. Graft flow parameters measured by both methods were compared. Compared with the conventional TTFM, the flow reduction TTFM resulted in significantly lower mean graft blood flow (P < 0.05); in contrast, yielded significantly higher pulsatility index (P < 0.05). Diastolic filling was not significantly different between the two methods and was > 50% in both cases. Interestingly, the flow reduction TTFM identified two defective middle distal anastomoses that the conventional TTFM failed to detect. Graft flows near the defective distal anastomoses were improved substantially after revision. In this study, we found that temporary reduction of graft flow during TTFM seemed to enhance the sensitivity of TTFM to less-than-critical anastomotic defects in a sequential graft and to improve the overall accuracy of the intraoperative assessment of anastomotic quality in sequential vein grafting.
引用
收藏
页码:938 / 943
页数:6
相关论文
共 26 条
[1]   Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography [J].
Bassri, Hosseinali ;
Salari, Farzad ;
Noohi, Fereidoun ;
Motevali, Marzieh ;
Abdi, Seifollah ;
Givtaj, Nader ;
Raissi, Kamal ;
Haghjoo, Majid .
BMC CARDIOVASCULAR DISORDERS, 2009, 9
[2]   Transit time flow measurement: Experimental validation and comparison of three different systems [J].
Beldi, G ;
Bosshard, A ;
Hess, OM ;
Althaus, U ;
Walpoth, BH .
ANNALS OF THORACIC SURGERY, 2000, 70 (01) :212-217
[3]   Neural network pattern recognition analysis of graft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG [J].
Cerrito, PB ;
Koenig, SC ;
VanHimbergen, DJ ;
Jaber, SF ;
Ewert, DL ;
Spence, PA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 16 (01) :88-93
[4]   Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting [J].
D'Ancona, G ;
Karamanoukian, HL ;
Ricci, M ;
Schmid, S ;
Bergsland, J ;
Salerno, TA .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (03) :287-293
[5]   Graft patency verification in coronary artery bypass grafting: Principles and clinical applications of transit time flow measurement [J].
D'Ancona, G ;
Karamanoukian, HL ;
Ricci, M ;
Bergsland, J ;
Salerno, TA .
ANGIOLOGY, 2000, 51 (09) :725-731
[6]   Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery [J].
Di Giammarco, Gabriele ;
Pano, Marco ;
Cirmeni, Sergio ;
Pelini, Piero ;
Vitolla, Giuseppe ;
Di Mauro, Michele .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (03) :468-474
[7]   Routine Off-Pump Coronary Artery Bypass Grafting Is Safe and Feasible in High-Risk Patients With Left Main Disease [J].
Emmert, Maximilian Y. ;
Salzberg, Sacha P. ;
Seifert, Burkhardt ;
Schurr, Ulrich P. ;
Hoerstrup, Simon P. ;
Reuthebuch, Oliver ;
Genoni, Michele .
ANNALS OF THORACIC SURGERY, 2010, 89 (04) :1125-1130
[8]   Angiographic assessment of sequential and individual coronary artery bypass grafting [J].
Farsak, B ;
Tokmakoglu, H ;
Kandemir, Ö ;
Günaydin, S ;
Aydin, H ;
Yorgancioglu, C ;
Süzer, K ;
Zorlutuna, Y .
JOURNAL OF CARDIAC SURGERY, 2003, 18 (06) :524-529
[9]  
Farsak B, 2003, J CARDIOVASC SURG, V18, P530