Bisphenol A determination in baby bottles by chemiluminescence enzyme-linked immunosorbent assay, lateral flow immunoassay and liquid chromatography tandem mass spectrometry

被引:84
作者
Maiolini, Elisabetta [1 ]
Ferri, Elida [1 ]
Pitasi, Agata Laura [1 ]
Montoya, Angel [2 ]
Di Giovanni, Manuela [3 ]
Errani, Ermanno [3 ]
Girotti, Stefano [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Pharm & Biotechnol, I-40127 Bologna, Italy
[2] Univ Politecn Valencia, Interuniv Res Inst Bioengn & Human Ctr Technol I3, Valencia 46022, Spain
[3] Reg Agcy Environm Protect ARPA, Bologna, Italy
关键词
MIGRATION; EXPOSURE; ELISA;
D O I
10.1039/c3an00552f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two immunoassays, a Lateral Flow ImmunoAssay (LFIA) based on colloidal gold nanoparticle labels and an indirect competitive chemiluminescence enzyme-linked immunosorbent assay (CL-ELISA), were developed and a high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was optimized to assess the possible release of bisphenol A (BPA, 4,4'-isopropylidenediphenol) from different plastic baby bottles treated with simulating solutions. Coating conjugate concentration, anti-BPA antibody dilution, incubation time of the primary and secondary antibodies, and tolerance to different organic solvents were optimized to obtain the best performance of the ELISA with chemiluminescent end-point detection. The influence of different buffers on LFIA performance was also evaluated. Both methods showed good repeatability (mean CV value around 13%) and sensitivity. Reproducibility tests for CL-ELISA gave a mean CV value of about 25%. The IC50 and Limit of Detection (LOD) values of CL-ELISA were 0.2 and 0.02 ng mL(-1), respectively. The LOD of LFIA was 0.1 mu g mL(-1). A LC-MS/MS method was also optimized. The separation was performed in a C18 column with a triple-quadrupole mass spectrometer with electrospray ionisation interface. The method showed a good linearity in the range 2 to 500 ng mL(-1), with a regression coefficient of 0.998. In the simulating solutions the detection and quantification limits, calculated by the signal to noise level of 3 (S/N = 3), were 5.8 ng mL(-1) and 17.4 ng mL(-1), respectively. This limit of quantification was about 3 and 35 times lower than the permitted limits set by the official method CEN/TS 13130-13 (0.05 mu g mL(-1)) and by the Directive 2004/19/EC (0.6 mu g mL(-1)), respectively. The methods were applied to determine BPA release from baby bottles, performing repeated procedures according to EU and national regulations. The results demonstrated that no BPA migration from the tested plastic materials occurred with only one exception. The migrated amount, above the regulatory limits, was detected by all the mentioned assays.
引用
收藏
页码:318 / 324
页数:7
相关论文
共 30 条
[1]  
[Anonymous], 1993, OFF J EUR COMMUNITIE, V90, P22
[2]  
[Anonymous], 2011, Off J Eur Union, VL26, P11
[3]  
[Anonymous], 2010, CANADA GAZETTE 1013, V144, P1806
[4]  
Baldi F., BABY BOTTLE STRUGGLI
[5]   Analytical methods for the determination of bisphenol A in food [J].
Ballesteros-Gomez, Ana ;
Rubio, Soledad ;
Perez-Bendito, Dolores .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (03) :449-469
[6]   Development of chemiluminescent ELISAs to DDT and its metabolites in food and environmental samples [J].
Botchkareva, AE ;
Eremin, SA ;
Montoya, A ;
Manclús, JJ ;
Mickova, B ;
Rauch, P ;
Fini, F ;
Girotti, S .
JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 283 (1-2) :45-57
[7]   Perinatal Exposure to Environmentally Relevant Levels of Bisphenol A Decreases Fertility and Fecundity in CD-1 Mice [J].
Cabaton, Nicolas J. ;
Wadia, Perinaaz R. ;
Rubin, Beverly S. ;
Zalko, Daniel ;
Schaeberle, Cheryl M. ;
Askenase, Michael H. ;
Gadbois, Jennifer L. ;
Tharp, Andrew P. ;
Whitt, Gregory S. ;
Sonnenschein, Carlos ;
Soto, Ana M. .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2011, 119 (04) :547-552
[8]   Endocrine-Disrupting Chemicals: An Endocrine Society Scientific Statement [J].
Diamanti-Kandarakis, Evanthia ;
Bourguignon, Jean-Pierre ;
Giudice, Linda C. ;
Hauser, Russ ;
Prins, Gail S. ;
Soto, Ana M. ;
Zoeller, R. Thomas ;
Gore, Andrea C. .
ENDOCRINE REVIEWS, 2009, 30 (04) :293-342
[9]   Advances in immunochemical technologies for analysis of organic pollutants in the environment [J].
Farre, Marinella ;
Kantiani, Lina ;
Barcelo, Damia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (11) :1100-1112
[10]   An immunoassay for bisphenol A based on direct hapten conjugation to the polystyrene surface of microtiter plates [J].
Feng, Yi ;
Ning, Baoan ;
Su, Pu ;
Wang, Hongyong ;
Wang, Caihong ;
Chen, Fusheng ;
Gao, Zhixian .
TALANTA, 2009, 80 (02) :803-808