Contrast-enhanced 3D MR perfusion of the lung: Application of parallel imaging technique in healthy subjects

被引:21
|
作者
Ley, S
Fink, C
Purderbach, M
Plathow, C
Risse, F
Kreitner, KF
Kauczor, HU
机构
[1] Deutsch Krebsforschungszentrum, E010, D-69120 Heidelberg, Germany
[2] Univ Mainz, Klin & Poliklin Radiol, D-6500 Mainz, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2004年 / 176卷 / 03期
关键词
perfusion; lung; phase-contrast; MRI; parallel imaging;
D O I
10.1055/s-2004-812755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of lung perfusion by contrast-enhanced 3D MRI using partial parallel imaging techniques. Materials and Methods: Eight healthy volunteers were examined using a contrast-enhanced dynamic FLASH 3D sequence with partial parallel imaging technique at 1.5 T MRI with a TA of 1.5 sec. The whole lung was covered by 36 coronal slices. A ventral, middle and dorsal, slice of each lung was manually segmented and signal-to-time curves were computed. For absolute quantification of blood flow through the right and left pulmonary artery, phase-contrast flow measurements were performed. Results: No significant difference was found between the signal intensity in the right (8.9 +/- 2.6) and left (8.0 +/- 3.5) lung, corresponding to a left-to-right signal intensity ratio of 0.9. A significantly higher signal intensity was found in the dorsal regions of the lungs (p = 0.01) compared to the ventral regions. The time to peak of the signal intensity was significantly shorter in the dorsal (15.3 sec) and middle (15.7 sec) regions of the lungs (p = 0.03 and p = 0.04, respectively) than in the ventral regions (16.3 sec). The ratio between blood flow through the left (2.2 L/min) and right (2.7 L/min) lung was 0.84. Conclusion: Partial parallel image acquisition can assess the perfusion of the lungs at high temporal resolution. The perfusion is slightly higher on the right than on the left. The signal increases faster and has a higher peak in the dorsal lung regions.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [41] Improvement of the Diagnostic Performance of Facial Neuritis Using Contrast-Enhanced 3D T1 Black-Blood Imaging: Comparison with Contrast-Enhanced 3D T1-Spoiled Gradient-Echo Imaging
    Lee, Seun-Ah
    Jo, Sang-Won
    Chang, Suk-Ki
    Kwon, Ki-Han
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [42] Time-resolved, high-resolution contrast-enhanced MR angiography of dialysis shunts using the CENTRA keyhole technique with parallel imaging
    Mende, Katja A.
    Froehlich, Johannes M.
    von Weymarn, Constantin
    Hoogeveen, Romhild
    Kistler, Thomas
    Zollikofer, Christoph L.
    Wentz, Klaus U.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (04) : 832 - 840
  • [43] Dynamic contrast-enhanced 3-T MR imaging in cervical cancer before and after concurrent chemoradiotherapy
    Kim, Jae-Hun
    Kim, Chan Kyo
    Park, Byung Kwan
    Park, Sung Yoon
    Huh, Seung Jae
    Kim, Bohyun
    EUROPEAN RADIOLOGY, 2012, 22 (11) : 2533 - 2539
  • [44] Semiquantitative assessment of uterine perfusion using first pass dynamic contrast-enhanced MR imaging for patients treated with uterine fibroid embolization
    Li, W
    Brophy, DP
    Chen, Q
    Edelman, RR
    Prasad, PV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (06) : 1004 - 1008
  • [45] Contrast-enhanced first-pass myocardial perfusion magnetic resonance Imaging with parallel acquisition at 3.0 tesla
    Ruan, Chun
    Yang, Scott H.
    Cusi, Kenneth
    Gao, Feng
    Clarke, Geoffrey D.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 352 - 360
  • [46] Multiparametric oxygen-enhanced functional lung imaging in 3D
    Hemberger, Kathrin R. F.
    Jakob, Peter M.
    Breuer, Felix A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (03) : 217 - 226
  • [47] Operating characteristics of hyperpolarized 3He and arterial spin tagging in MR Imaging of ventilation and perfusion in healthy subjects
    Rizi, RR
    Lipson, DA
    Dimitrov, IE
    Ishii, M
    Roberts, DA
    ACADEMIC RADIOLOGY, 2003, 10 (05) : 502 - 508
  • [48] Comparison of Contrast-Enhanced 3D Imaging with 2D Imaging in the Evaluation of Perianal Fistula at 3T: A Prospective Observational Study
    Kv, Abdulla
    Arunachalam, Venkatesh Kasi
    Sherene, Haleema
    Ethiraju, Vijayakumaran
    Ranganathan, Rupa
    Sm, Gowtham
    Rajasekaran, Sriman
    Mehta, Pankaj
    Cherian, Mathew
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024, 34 (01): : 95 - 102
  • [49] Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects
    Ohno, Y
    Hatabu, H
    Murase, K
    Higashino, T
    Kawamitsu, H
    Watanabe, H
    Takenaka, D
    Fujii, M
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) : 353 - 365
  • [50] Accelerated Bilateral Dynamic Contrast-Enhanced 3D Spiral Breast MRI Using TSENSE
    Han, Misung
    Daniel, Bruce L.
    Hargreaves, Brian A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1425 - 1434