Contrast-enhanced 3D MR perfusion of the lung: Application of parallel imaging technique in healthy subjects

被引:21
|
作者
Ley, S
Fink, C
Purderbach, M
Plathow, C
Risse, F
Kreitner, KF
Kauczor, HU
机构
[1] Deutsch Krebsforschungszentrum, E010, D-69120 Heidelberg, Germany
[2] Univ Mainz, Klin & Poliklin Radiol, D-6500 Mainz, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2004年 / 176卷 / 03期
关键词
perfusion; lung; phase-contrast; MRI; parallel imaging;
D O I
10.1055/s-2004-812755
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Evaluation of lung perfusion by contrast-enhanced 3D MRI using partial parallel imaging techniques. Materials and Methods: Eight healthy volunteers were examined using a contrast-enhanced dynamic FLASH 3D sequence with partial parallel imaging technique at 1.5 T MRI with a TA of 1.5 sec. The whole lung was covered by 36 coronal slices. A ventral, middle and dorsal, slice of each lung was manually segmented and signal-to-time curves were computed. For absolute quantification of blood flow through the right and left pulmonary artery, phase-contrast flow measurements were performed. Results: No significant difference was found between the signal intensity in the right (8.9 +/- 2.6) and left (8.0 +/- 3.5) lung, corresponding to a left-to-right signal intensity ratio of 0.9. A significantly higher signal intensity was found in the dorsal regions of the lungs (p = 0.01) compared to the ventral regions. The time to peak of the signal intensity was significantly shorter in the dorsal (15.3 sec) and middle (15.7 sec) regions of the lungs (p = 0.03 and p = 0.04, respectively) than in the ventral regions (16.3 sec). The ratio between blood flow through the left (2.2 L/min) and right (2.7 L/min) lung was 0.84. Conclusion: Partial parallel image acquisition can assess the perfusion of the lungs at high temporal resolution. The perfusion is slightly higher on the right than on the left. The signal increases faster and has a higher peak in the dorsal lung regions.
引用
收藏
页码:330 / 334
页数:5
相关论文
共 50 条
  • [1] CONTRAST-ENHANCED MR IMAGING OF THE LUNG - ASSESSMENTS OF VENTILATION AND PERFUSION
    BERTHEZENE, Y
    VEXLER, V
    CLEMENT, O
    MUHLER, A
    MOSELEY, ME
    BRASCH, RC
    RADIOLOGY, 1992, 183 (03) : 667 - 672
  • [2] Dynamic contrast-enhanced MR perfusion imaging of head and neck tumors at 3 Tesla
    Furukawa, Matakazu
    Parvathaneni, Upendra
    Maravilla, Kenneth
    Richards, Todd L.
    Anzai, Yoshimi
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (07): : 923 - 929
  • [3] Diagnostic contribution of contrast-enhanced 3D MR imaging of peripheral nerve pathology
    Deshmukh, Swati
    Tegtmeyer, Kyle
    Kovour, Mounisha
    Ahlawat, Shivani
    Samet, Jonathan
    SKELETAL RADIOLOGY, 2021, 50 (12) : 2509 - 2518
  • [4] Diagnostic contribution of contrast-enhanced 3D MR imaging of peripheral nerve pathology
    Swati Deshmukh
    Kyle Tegtmeyer
    Mounisha Kovour
    Shivani Ahlawat
    Jonathan Samet
    Skeletal Radiology, 2021, 50 : 2509 - 2518
  • [5] High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE)
    Walter, C
    Philippi, G
    Westerhausen, R
    Kooijman, H
    Hoffmann, HG
    Busch, HP
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (09): : 1244 - 1250
  • [6] Dynamic contrast-enhanced MR imaging to assess physiologic variations of myometrial perfusion
    Thomassin-Naggara, Isabelle
    Balvay, Daniel
    Cuenod, Charles A.
    Darai, Emile
    Marsault, Claude
    Bazot, Marc
    EUROPEAN RADIOLOGY, 2010, 20 (04) : 984 - 994
  • [7] Dynamic contrast-enhanced MR imaging to assess physiologic variations of myometrial perfusion
    Isabelle Thomassin-Naggara
    Daniel Balvay
    Charles A. Cuenod
    Emile Daraï
    Claude Marsault
    Marc Bazot
    European Radiology, 2010, 20 : 984 - 994
  • [8] Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis—initial results
    Monika Eichinger
    Michael Puderbach
    Christian Fink
    Julie Gahr
    Sebastian Ley
    Christian Plathow
    Siegfried Tuengerthal
    Ivan Zuna
    Frank-Michael Müller
    Hans-Ulrich Kauczor
    European Radiology, 2006, 16 : 2147 - 2152
  • [9] Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis -: initial results
    Eichinger, Monika
    Puderbach, Michael
    Fink, Christian
    Gahr, Julie
    Ley, Sebastian
    Plathow, Christian
    Tuengerthal, Siegfried
    Zuna, Ivan
    Mueller, Frank-Michael
    Kauczor, Hans-Ulrich
    EUROPEAN RADIOLOGY, 2006, 16 (10) : 2147 - 2152
  • [10] Hybrid peripheral 3D contrast-enhanced MR angiography of calf and foot vasculature
    Tongdee, R
    Narra, VR
    McNeal, G
    Hildebolt, CF
    El-Merhi, F
    Foster, G
    Brown, JJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (06) : 1746 - 1753