Control of doubly fed induction generator; wind power; torque-speed characteristics; reactive power-speed characteristics; MODE;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper is concerned with the control of doubly fed induction generator applied in wind power technology. Assuming stator flux oriented vector control, the torque and power relations are derived. Using the relations, the slip versus torque and slip versus stator reactive power characteristics are drafted in subsynchronous and in supersynchronous state for investigating the control possibilities of the generator side converter supplying the rotor circuit. The effects of the d and q component of the converter output voltage for the torque, power and speed are studies in qualitative and quantitative way. The active and reactive power flows in stator and rotor side are shown.
引用
收藏
页码:368 / 375
页数:8
相关论文
共 50 条
  • [1] Power Smoothing of Doubly Fed Induction Generator Wind Turbines
    Luu, T.
    Abedini, A.
    Nasiri, A.
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 2292 - 2297
  • [2] Performance Analysis of Unified Doubly-Fed Induction Generator for Wind Power Application
    Rajpurohit, B. S.
    Singh, S. N.
    WIND ENGINEERING, 2015, 39 (05) : 533 - 548
  • [3] Reactive power capability of a wind turbine with doubly fed induction generator
    Lund, Torsten
    Sorensen, Poul
    Eek, Jarle
    WIND ENERGY, 2007, 10 (04) : 379 - 394
  • [4] Transient states of wind power plant with doubly fed induction generator
    Lerch, Tomasz
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (06): : 118 - 124
  • [5] Reactive Power Capability of the Wind Turbine with Doubly Fed Induction Generator
    Tian, J.
    Su, C.
    Chen, Z.
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5312 - 5317
  • [6] Decoupled Control of Doubly Fed Induction Generator for Wind Power System
    Ning, Jiaxin
    Gao, Wenzhong
    Ojo, Joseph
    2008 40TH NORTH AMERICAN POWER SYMPOSIUM (NAPS 2008), 2008, : 261 - 266
  • [7] SMES Based Excitation System for Doubly-Fed Induction Generator in Wind Power Application
    Shi, Jing
    Tang, Yuejin
    Xia, Yajun
    Ren, Li
    Li, Jingdong
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 1105 - 1108
  • [8] Flux Programmed Hybrid Mode Operation of a Doubly Fed Induction Generator for Wind Power Application
    Mukherjee, S.
    Kastha, D.
    IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES 2012), 2012,
  • [9] An Improved Direct Power Control of A Doubly Fed Induction Generator Wind Power System
    Mahmodicherati, Sam
    Elbuluk, Malik
    Sozer, Yilmaz
    2013 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2013,
  • [10] Performance study of a doubly fed wind-power induction generator under network disturbances
    Seman, Slavomir
    Niiranen, Jouko
    Kanerva, Sami
    Arkkio, Antero
    Saitz, Julius
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (04) : 883 - 890