Initial clinical results for breath-hold CT-based processing of respiratory-gated PET acquisitions

被引:40
作者
Fin, Loic [2 ]
Daouk, Joeel [2 ]
Morvan, Julie [2 ]
Bailly, Pascal [1 ,2 ]
El Esper, Isabelle [2 ]
Saidi, Lazhar [2 ]
Meyer, Marc-Etienne [2 ]
机构
[1] CHU Amiens, Hop Sud, Unite TEP, Nucl Med Serv, F-80054 Amiens, France
[2] Amiens Univ Hosp, Dept Nucl Med, Amiens, France
关键词
PET-CT; Respiratory motion; Respiratory gating; Breath-hold CT;
D O I
10.1007/s00259-008-0858-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Respiratory motion causes uptake in positron emission tomography (PET) images of chest structures to spread out and misregister with the CT images. This misregistration can alter the attenuation correction and thus the quantisation of PET images. In this paper, we present the first clinical results for a respiratory-gated PET (RG-PET) processing method based on a single breath-hold CT (BH-CT) acquisition, which seeks to improve diagnostic accuracy via better PET-to-CT co-registration. We refer to this method as "CT-based" RG-PET processing. Methods Thirteen lesions were studied. Patients underwent a standard clinical PET protocol and then the CT-based protocol, which consists of a 10-min List Mode RG-PET acquisition, followed by a shallow end-expiration BH-CT. The respective performances of the CT-based and clinical PET methods were evaluated by comparing the distances between the lesions' centroids on PET and CT images. SUVMAX and volume variations were also investigated. Results The CT-based method showed significantly lower (p = 0.027) centroid distances (mean change relative to the clinical method=-49%; range=-100% to 0%). This led to higher SUVMAX (mean change=+33%; range=-4% to 69%). Lesion volumes were significantly lower (p=0.022) in CT-based PET volumes (mean change=-39%: range=-74% to -1%) compared with clinical ones. Conclusions A CT-based RG-PET processing method can be implemented in clinical practice with a small increase in radiation exposure. It improves PET-CT co-registration of lung lesions and should lead to more accurate attenuation correction and thus SUV measurement.
引用
收藏
页码:1971 / 1980
页数:10
相关论文
共 40 条
[1]  
Ahuja V, 1998, CANCER, V83, P918, DOI 10.1002/(SICI)1097-0142(19980901)83:5<918::AID-CNCR17>3.3.CO
[2]  
2-#
[3]   Applications of PET in lung cancer [J].
Al-Sugair, A ;
Coleman, RE .
SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (04) :303-319
[4]   Accuracy of whole-body dual-modality fluorine-18-2-fluoro-2-deoxy-D-glucose positron emission tomography and computed tomography (FDG-PET/CT) for tumor staging in solid tumors: Comparison with CT and PET [J].
Antoch, G ;
Saoudi, N ;
Kuehl, H ;
Dahmen, G ;
Mueller, SP ;
Beyer, T ;
Bockisch, A ;
Debatin, JF ;
Freudenberg, LS .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (21) :4357-4368
[5]  
Beyer T, 2004, J NUCL MED, V45, p25S
[6]  
Biehl KJ, 2006, J NUCL MED, V47, P1808
[7]   PET-CT: accuracy of PET and CT spatial registration of lung lesions [J].
Cohade, C ;
Osman, M ;
Marshall, LT ;
Wahl, RL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (05) :721-726
[8]  
Daouk J, 2007, EUR J NUCL MED MOL I, V34, pS145
[9]  
DAOUK J, 2008, P 5 IEEE INT S BIOM
[10]   Respiratory gating in positron emission tomography:: A quantitative comparison of different gating schemes [J].
Dawood, Mohammad ;
Buether, Florian ;
Lang, Norbert ;
Schober, Otmar ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2007, 34 (07) :3067-3076