Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Cone Beam Computed Tomography and Virtual Cloning: A Review
    Sarkar, Anand Shankar
    Hegde, Shruthi
    Ajila, Vidya
    Darwin, Deepthi
    [J]. JOURNAL OF HEALTH AND ALLIED SCIENCES NU, 2024, 14 (01): : 17 - 22
  • [42] Diagnostic Accuracy of Cone Beam Computed Tomography for Dimensional Linear Measurements in the Mandible
    Halperin-Sternfeld, Michal
    Machtei, Eli E.
    Horwitz, Jacob
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 593 - 599
  • [43] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Erem, Geoffrey
    Ameda, Faith
    Otike, Caroline
    Olwit, William
    Mubuuke, Aloysius G.
    Schandorf, Cyril
    Kisolo, Akisophel
    Kawooya, Michael G.
    [J]. BMC MEDICAL IMAGING, 2022, 22 (01)
  • [44] Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels
    Geoffrey Erem
    Faith Ameda
    Caroline Otike
    William Olwit
    Aloysius G. Mubuuke
    Cyril Schandorf
    Akisophel Kisolo
    Michael G. Kawooya
    [J]. BMC Medical Imaging, 22
  • [45] Diagnostic Accuracy of Cone-Beam Computed Tomography in the Evaluation of Chronic Rhinosinusitis
    Zojaji, Ramin
    Naghibzadeh, Masoud
    Baf, Morteza Mazloum Farsi
    Nekooei, Sirous
    Bataghva, Behrokh
    Noorbakhsh, Sara
    [J]. ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2015, 77 (01): : 55 - 60
  • [46] Diagnostic efficacy of cone beam computed tomography in paediatric dentistry: a systematic review
    Horner, K.
    Barry, S.
    Dave, M.
    Dixon, C.
    Littlewood, A.
    Pang, C. L.
    Sengupta, A.
    Srinivasan, V.
    [J]. EUROPEAN ARCHIVES OF PAEDIATRIC DENTISTRY, 2020, 21 (04) : 407 - 426
  • [47] Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery
    Husain, Adib Al-Haj
    Mergen, Victor
    Valdec, Silvio
    Husain, Nadin Al-Haj
    Stadlinger, Bernd
    Essig, Harald
    Frauenfelder, Thomas
    Kessler, Peter
    Lie, Suen An Nynke
    Alkadhi, Hatem
    Winklhofer, Sebastian
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [48] Computed tomography, cone beam computed tomography and magnetic resonance imaging diagnostic possibilities in dentistry
    Schulze, Ralf Kurt Willy
    [J]. INTERNATIONAL JOURNAL OF STOMATOLOGY & OCCLUSION MEDICINE, 2011, 4 (01) : 2 - 9
  • [49] Local diagnostic reference levels for cardiac computed tomography
    Pilat, Wiktoria
    Kidon-Szoltysek, Joanna
    Stasiow, Bartlomiej
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (04):
  • [50] In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography
    Benic, Goran I.
    Sancho-Puchades, Manuel
    Jung, Ronald E.
    Deyhle, Hans
    Haemmerle, Christoph H. F.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 378 - 383