Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Cone beam computed tomography and its application in dental practice
    Correia, Francisco
    Salgado, Abel
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2012, 53 (01): : 47 - 52
  • [32] Cone Beam Computed Tomography Scanning and Diagnosis for Dental Implants
    Greenberg, Alex M.
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2015, 27 (02) : 185 - +
  • [33] In Vitro Detection of Dental Root Fractures with Cone Beam Computed Tomography (CBCT)
    Fisekcioglu, Erdogan
    Dolekoglu, Semanur
    Ilguy, Mehmet
    Ersan, Nilufer
    Ilguy, Dilhan
    IRANIAN JOURNAL OF RADIOLOGY, 2014, 11 (01)
  • [34] Dental Cone-Beam Computed Tomography: Are the Eye Lens and Thyroid at Risk?
    Albahiti, Sarah K.
    Jadu, Fatima M.
    Badr, Fatma
    Khalifa, Hanadi
    Khan, Emad
    Khafaji, Mawya
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2024, 14 (01) : 77 - 82
  • [35] Cone Beam Computed Tomography Imaging in Dental Implants: A Primer for Clinical Radiologists
    Bernaerts, Anja
    Barbier, Lieven
    Abeloos, Johan
    De Backer, Tom
    Bosmans, Frederik
    Vanhoenacker, Filip M.
    Casselman, Jan
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2020, 24 (05) : 499 - 509
  • [36] A new formula for converting dose-area product to effective dose in dental cone-beam computed tomography
    Pauwels, Ruben
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [37] Computed gray levels in multislice and cone-beam computed tomography
    Azeredo, Fabiane
    de Menezes, Luciane Macedo
    Enciso, Reyes
    Weissheimer, Andre
    de Oliveira, Rogerio Belle
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2013, 144 (01) : 147 - 155
  • [38] Comparative dosimetry of dental cone beam computed tomography, panoramic radiography, and multislice computed tomography
    Sezgin, Omer Said
    Kayipmaz, Sadettin
    Yasar, Dogan
    Yilmaz, Ahmet Berhan
    Ozturk, Mehmet Halil
    ORAL RADIOLOGY, 2012, 28 (01) : 32 - 37
  • [39] Establishment of diagnostic reference levels for common multi-detector computed tomography examinations in Iran
    Mohsen Najafi
    Mohammad Reza Deevband
    Mohsen Ahmadi
    Mohammad Reza Kardan
    Australasian Physical & Engineering Sciences in Medicine, 2015, 38 : 603 - 609
  • [40] Use of cone beam computed tomography in otolaryngologic treatments
    Cakli, Hamdi
    Cingi, Cemal
    Ay, Yazgi
    Oghan, Fatih
    Ozer, Torun
    Kaya, Ercan
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (03) : 711 - 720