Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] A Review of Diagnostic Reference Levels in Computed Tomography
    Dawd, Jemal Edris
    Ozsahin, Dilber Uzun
    Ozsahin, Ilker
    CURRENT MEDICAL IMAGING, 2022, 18 (06) : 623 - 632
  • [22] Role of cone-beam computed tomography in diagnostic otorhinolaryngological imaging
    Perenyi Adam
    Bella Zsolt
    Barath Zoltan
    Magyar Peter
    Nagy Katalin
    Rovo Laszlo
    ORVOSI HETILAP, 2016, 157 (02) : 52 - 58
  • [23] Australian diagnostic reference levels for multi detector computed tomography
    Hayton, Anna
    Wallace, Anthony
    Marks, Paul
    Edmonds, Keith
    Tingey, David
    Johnston, Peter
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2013, 36 (01) : 19 - 26
  • [25] Cone beam computed tomography for diagnostic imaging prior to dental implant therapy in the posterior maxilla with special emphasis on the visualization of the maxillary sinus
    Bornstein, Michael M.
    Janner, Simone F. M.
    Yeung, Andy W. K.
    IMPLANTOLOGIE, 2018, 26 (01): : 7 - 17
  • [26] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Rong-yang Wang
    Min Han
    Hong Liu
    Chun-ling Wang
    Hong-hong Xian
    Lei Zhang
    Shi-jie Zhang
    Dong-xu Liu
    Journal of Zhejiang University SCIENCE B, 2012, 13 : 942 - 947
  • [27] Proposed Diagnostic Reference Levels in the Missouri/Southern Illinois Region Associated with Cone-beam Computed Tomography Use in Endodontics
    Popkowski, Arthur
    Rhodes, S. Craig
    Hatton, John F.
    JOURNAL OF ENDODONTICS, 2024, 50 (07) : 966 - 975
  • [28] Establishment of reference mandibular plane for anterior alveolar morphology evaluation using cone beam computed tomography
    Wang, Rong-yang
    Han, Min
    Liu, Hong
    Wang, Chun-ling
    Xian, Hong-hong
    Zhang, Lei
    Zhang, Shi-jie
    Liu, Dong-xu
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2012, 13 (11): : 942 - 947
  • [29] Cone beam computed tomography and its application in dental practice
    Correia, Francisco
    Salgado, Abel
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2012, 53 (01): : 47 - 52
  • [30] Cone Beam Computed Tomography Scanning and Diagnosis for Dental Implants
    Greenberg, Alex M.
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2015, 27 (02) : 185 - +