Establishment of national diagnostic reference levels in dental cone beam computed tomography in Switzerland

被引:14
|
作者
Deleu, Marine [1 ,2 ]
Dagassan, Dorothea [3 ]
Berg, Isabelle [4 ]
Bize, Julie [1 ]
Dula, Karl [5 ]
Lenoir, Vincent [2 ]
Ott, Barbara [6 ]
Ott, Julien G. [7 ]
Verdun, Francis R. [1 ]
Weber, Robert [8 ]
Ziglinas, Panagiotis [9 ]
Zingariello, Cesare [2 ]
Merce, Marta Sans [2 ]
机构
[1] Lausanne Univ Hosp, Inst Radiat Phys, Lausanne, Switzerland
[2] Univ Hosp Geneva, Dept Radiol, Geneva, Switzerland
[3] Univ Basel, Univ Ctr Dent Med Basel, Ctr Dent Imaging, Basel, Switzerland
[4] Univ Hosp Basel, Basel, Switzerland
[5] Univ Bern, Bern, Switzerland
[6] Fed Off Publ Hlth, Radiat Protect Div, Bern, Switzerland
[7] HNO Zentrum, Bern, Switzerland
[8] Inselspital Bern, Div Med Radiat Phys, Bern, Switzerland
[9] Praxisklinik, Basel, Switzerland
关键词
Diagnostic reference level; Cone beam computed tomography; Dental Radiography; Dose area product; Clinical DRL; DENTISTRY; CT;
D O I
10.1259/dmfr.20190468
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to establish diagnostic reference levels (DRLs) in the field of dental maxillofacial and ear-nose-throat (ENT) practices using cone beam CT (CBCT) in Switzerland. Methods: A questionnaire was sent to owners of CBCTs in Switzerland; to a total of 612 institutions. The answers were analyzed for each indication, provided that enough data were available. The DRLs were defined as the 75th percentile of air kerma product distribution (P-KA). Results: 227 answers were collected (38% of all centers). Third quartile of P-KA, values were obtained for five dental indications: 662 mGy cm(2) for wisdom tooth, 683 mGy cm(2) for single tooth implant treatment, 542 mGy cm(2) for tooth position anomalies, 569 mGy cm(2) for pathological dentoalveolar modifications, and 639 mGy cm(2) for endodontics. The standard field of view (FOV) size of 5 cm in diameter x 5 cm in height was proposed. Conclusions: Large ranges of FOV and P were found for a given indication, demonstrating the importance of establishing DRLs as well as FOV recommendations in view of optimizing the present practice. For now, only DRLs for dental and maxillofacial could be defined; because of a lack of ENT data, no DRL values for ENT practices could be derived from this survey.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Establishing national paediatric computed tomography diagnostic reference levels in Ghana
    Shirazu, Issahaku
    Sackey, Theophilus A.
    Edziah, Raymond
    Boateng, Yaw Mensah
    Schandorf, Cyril.
    HEALTH AND TECHNOLOGY, 2024, 14 (06) : 1187 - 1198
  • [12] Establishment of national diagnostic reference levels for computed tomography procedures in Sri Lanka: first nationwide dose survey
    Amalaraj, T.
    Satharasinghe, Duminda
    Pallewatte, Aruna
    Jeyasugiththan, Jeyasingam
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [13] 2021 NATIONAL DIAGNOSTIC REFERENCE LEVELS FOR PAEDIATRIC COMPUTED TOMOGRAPHY IN EGYPT
    Abdou, Sayed E.
    Salama, Dina H.
    Ahmad, Khaled A.
    Sallam, Abdelsattar M.
    El-Sayed, El-Sayed Mahmoud
    Talaat, M. S.
    El-Farrash, Rania A.
    Vassileva, J.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (07) : 423 - 433
  • [14] The Diagnostic Yield of Dental Radiography and Cone-Beam Computed Tomography for the Identification of Dentoalveolar Lesions in Cats
    Heney, Colleen M.
    Arzi, Boaz
    Kass, Philip H.
    Hatcher, David C.
    Verstraete, Frank J. M.
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [15] Diagnostic Yield of Dental Radiography and Cone-Beam Computed Tomography for the Identification of Anatomic Structures in Cats
    Heney, Colleen M.
    Arzi, Boaz
    Kass, Philip H.
    Hatcher, David C.
    Verstraete, Frank J. M.
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [16] Cone Beam Computed Tomography in Dentistry: What Dental Educators and Learners Should Know
    Adibi, Shawn
    Zhang, Wenjian
    Servos, Tom
    O'Neill, Paula N.
    JOURNAL OF DENTAL EDUCATION, 2012, 76 (11) : 1437 - 1442
  • [17] Prevalence of ear disease in cats undergoing cone beam computed tomography for dental procedures
    Boothe, Hannah F.
    Volker, Mary Krakowski
    Tjepkema, Jennifer
    Hespel, Adrien-Maxence
    FRONTIERS IN VETERINARY SCIENCE, 2025, 12
  • [18] Effective dose range for dental cone beam computed tomography scanners
    Pauwels, Ruben
    Beinsberger, Jilke
    Collaert, Bruno
    Theodorakou, Chrysoula
    Rogers, Jessica
    Walker, Anne
    Cockmartin, Lesley
    Bosmans, Hilde
    Jacobs, Reinhilde
    Bogaerts, Ria
    Horner, Keith
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : 267 - 271
  • [19] ESTABLISHMENT OF LOCAL DIAGNOSTIC REFERENCE LEVELS FOR COMMON PROCEDURES OF COMPUTED TOMOGRAPHY IN YAZD PROVINCE
    Zamani, Hamed
    Masjedi, Hamidreza
    Omidi, Reza
    Hosein Zare, Mohammad
    RADIATION PROTECTION DOSIMETRY, 2020, 188 (02) : 222 - 231