Optimal Locating and Sizing of DG in Radial Distribution System Using Modified Shuffled Frog Leaping Algorithm

被引:1
|
作者
Asif, Rao Muhammad [1 ]
Rehman, Ateeq Ur [2 ]
Alsharabi, Naif [3 ,4 ]
Rabbani, Sajjad [5 ]
Shakir, Mustafa [1 ]
Malik, Nauman [1 ]
Rehman, Saif Ur [1 ]
Khan, Arfat Ahmad [6 ]
机构
[1] Super Univ Lahore, Dept Elect Engn, Lahore, Pakistan
[2] Govt Coll Univ, Dept Elect Engn, Lahore, Pakistan
[3] Univ Hail, Coll Comp Sci & Engn, Hail, Saudi Arabia
[4] Amran Univ, Coll Engn & Informat Technol, Amran, Yemen
[5] Lahore Coll Women Univ LCWU Lahore, Dept Elect Engn, Lahore, Pakistan
[6] Khon Kaen Univ, Coll Comp, Dept Comp Sci, Khon Kaen, Thailand
关键词
Distributed generation (DG); DG sizing and siting; Modified Shuffled Frog Leaping Algorithm (MSFLA); OPTIMIZATION ALGORITHM; GENERATION; ALLOCATION; PLACEMENT;
D O I
10.1080/03772063.2022.2150690
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several advantages have been achieved in distribution systems by adding Distributed Generation (DG). These benefits comprise minimizing power losses and improving the voltage profiles. Such benefits can be enhanced if DGs are optimally sized. This paper presents a DG in the distribution scheme to increase node voltages and reduce the power loss of radial distribution systems by using the Modified Shuffled Frog Leaping Algorithm (MSFLA) technique. The core objective is to decrease active-power losses of the system while keeping the voltage profiles within the defined limits of the system. This paper optimally allocates and sizes three types of DGs in various standard radial test systems and a practical radial feeder. Single and multiple DGs are considered for the proposed work by including some special cases. The standard test systems on which proposed work is performed are 33-bus and 69-bus radial feeders. A practical 43-bus radial feeder of factory area Faisalabad has also been taken under consideration for analysis. The Forward-Backward Sweep (FBS) scheme is selected for the load flow analysis, whereas MSFLA is chosen for finding of optimum size(s) and site(s) of DG(s). Various types of DGs results are retained separately and collectively. We have reduced the losses up to 85.14% and 96.1% for the 33-bus system and 69-bus respectively. The results will depict a significant improvement, both in the minimization of losses and also in improving the voltage profile. The results of multi DGs placement will be much more promising than those achieved after placing them independently.
引用
收藏
页码:2148 / 2165
页数:18
相关论文
共 50 条
  • [1] Optimal Locating and Sizing of DG and D-STATCOM Using Modified Shuffled Frog Leaping Algorithm
    Moazzami, Majid
    Shahinzadeh, Hossein
    Gharehpetian, Gevork B.
    Hosseinian, Seyed Hossein
    2017 2ND CONFERENCE ON SWARM INTELLIGENCE AND EVOLUTIONARY COMPUTATION (CSIEC), 2017, : 54 - 59
  • [2] Reconfiguration and DG Sizing and Placement Using Improved Shuffled Frog Leaping Algorithm
    Siahbalaee, Jafar
    Rezanejad, Neda
    Gharehpetian, Gevork B.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2019, 47 (16-17) : 1475 - 1488
  • [3] Multiobjective Optimization for Optimal Placement and Size of DG using Shuffled Frog Leaping Algorithm
    Yammani, Chandrasekhar
    Maheswarapu, Sydulu
    Matam, Sailajakumari
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 990 - 995
  • [4] A novel modified shuffled frog leaping algorithm to solve the optimal capacitor allocation problem in distribution system
    Akbari-Zadeh, Mohammad-Reza
    Vosoogh, Mahdi
    Mirjavadi, Mohammad
    Abbasi, Alireza
    JOURNAL OF INTELLIGENT & FUZZY SYSTEMS, 2014, 27 (01) : 299 - 306
  • [5] Comparison of Modified Shuffled Frog Leaping Algorithm and Other Algorithms for Optimal Distributed Generation Location and Sizing
    Nejad, Hadi Chahkandi
    Jahani, Rouzbeh
    Shayanfar, Heidar Ali
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2010, 5 (05): : 2286 - 2292
  • [6] Service Restoration in Distribution System Using Binary Shuffled Frog Leaping Algorithm
    Srivastava, Ishan
    Bhat, S. S.
    2016 INTERNATIONAL CONFERENCE ON ELECTRICAL POWER AND ENERGY SYSTEMS (ICEPES), 2016, : 226 - 231
  • [7] Determination of optimal tool path in drilling operation using modified shuffled frog leaping algorithm
    Dalavi A.M.
    Pawar P.J.
    Singh T.P.
    International Journal for Engineering Modelling, 2019, 32 (2-4): : 33 - 44
  • [8] OPTIMAL ALLOCATION AND SIZING OF DG IN A RADIAL DISTRIBUTION SYSTEM USING WHALE OPTIMIZATION ALGORITHM
    Marimuthu, A.
    Gnanambal, K.
    Priyanka, R.
    2017 IEEE INTERNATIONAL CONFERENCE ON INNOVATIONS IN GREEN ENERGY AND HEALTHCARE TECHNOLOGIES (IGEHT), 2017,
  • [9] Modified shuffled frog leaping algorithm for optimal switch placement in distribution automation system using a multi-objective fuzzy approach
    Sardou, I. Goroohi
    Banejad, M.
    Hooshmand, R.
    Dastfan, A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (06) : 493 - 502
  • [10] A Modified Shuffled Frog Leaping Algorithm for Optimal Tuning of Multivariable PID Controllers
    Huynh, Thai-Hoang