Simulation of Intrathrombus Fluid and Solute Transport Using In Vivo Clot Structures with Single Platelet Resolution

被引:48
|
作者
Voronov, Roman S. [1 ]
Stalker, Timothy J. [2 ]
Brass, Lawrence F. [2 ]
Diamond, Scott L. [1 ]
机构
[1] Univ Penn, Inst Med & Engn, Dept Chem & Biomol Engn, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Med & Pharmacol, Philadelphia, PA 19104 USA
关键词
Blood; Lattice Boltzmann; Confocal microscopy; Brownian; Diffusion; Permeability; Stresses; Drug delivery; Computation; Modeling; LATTICE BOLTZMANN METHOD; MICROPARTICLE FORMATION; TURBULENT TRANSPORT; NEWTONIAN FLOW; BLOOD; ACTIVATION; AGGREGATION; TRANSITION; VISCOSITY; FIBRIN;
D O I
10.1007/s10439-013-0764-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The mouse laser injury thrombosis model provides up to 0.22 mu m-resolved voxel information about the pore architecture of the dense inner core and loose outer shell regions of an in vivo arterial thrombus. Computational studies were conducted on this 3D structure to quantify transport within and around the clot: Lattice Boltzmann method defined vessel hemodynamics, while passive Lagrangian Scalar Tracking with Brownian motion contribution simulated diffusive-convective transport of various inert solutes (released from lumen or the injured wall). For an input average lumen blood velocity of 0.478 cm/s (measured by Doppler velocimetry), a 0.2 mm/s mean flow rate was obtained within the thrombus structure, most of which occurred in the 100-fold more permeable outer shell region (calculated permeability of the inner core was 10(-11) cm(2)). Average wall shear stresses were 80-100 dyne/cm(2) (peak values > 200 dyne/cm(2)) on the outer rough surface of the thrombus. Within the thrombus, small molecule tracers (0.1 kDa) experienced similar to 70,000 collisions/s and penetrated/exited it in about 1 s, whereas proteins (similar to 50 kDa) had similar to 9000 collisions/s and required about 10 s (tortuosity similar to 2-2.5). These simulations help define physical processes during thrombosis and constraints for drug delivery to the thrombus.
引用
收藏
页码:1297 / 1307
页数:11
相关论文
共 50 条
  • [1] Simulation of Intrathrombus Fluid and Solute Transport Using In Vivo Clot Structures with Single Platelet Resolution
    Roman S. Voronov
    Timothy J. Stalker
    Lawrence F. Brass
    Scott L. Diamond
    Annals of Biomedical Engineering, 2013, 41 : 1297 - 1307
  • [2] Fluid and solute transport in thrombi as function of platelet and fibrin density
    Wufsus, A. R.
    Neeves, K. B.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 326 - 326
  • [3] Modeling of solute transport in a single fracture using streamline simulation and experimental validation
    Jang, M
    Lee, J
    Choe, J
    Kang, JM
    JOURNAL OF HYDROLOGY, 2002, 261 (1-4) : 74 - 85
  • [4] Lattice Boltzmann simulation of solute transport in a single rough fracture
    Zhi DOU
    Zhi-fang ZHOU
    Water Science and Engineering, 2014, 7 (03) : 277 - 287
  • [5] Lattice Boltzmann simulation of solute transport in a single rough fracture
    Dou, Zhi
    Zhou, Zhi-fang
    WATER SCIENCE AND ENGINEERING, 2014, 7 (03) : 277 - 287
  • [6] The simulation for solute transport in soil using CIP method
    Kikuchi, T.
    Noborio, K.
    Katamachi, K.
    Abe, Y.
    SYSTEMS MODELING AND SIMULATION: THEORY AND APPLICATIONS, ASIA SIMULATION CONFERENCE 2006, 2007, : 24 - +
  • [7] SIMULATION OF SOLUTE TRANSPORT USING A TRANSFER-FUNCTION MODEL
    JURY, WA
    WATER RESOURCES RESEARCH, 1982, 18 (02) : 363 - 368
  • [8] Numerical solute transport simulation using fuzzy sets approach
    Dou, CH
    Woldt, W
    Bogardi, I
    Dahab, M
    JOURNAL OF CONTAMINANT HYDROLOGY, 1997, 27 (1-2) : 107 - 126
  • [9] FLUID AND SOLUTE TRANSPORT IN CAPD PATIENTS USING ULTRALOW SODIUM DIALYSATE
    IMHOLZ, ALT
    KOOMEN, GCM
    STRUIJK, DG
    ARISZ, L
    KREDIET, RT
    KIDNEY INTERNATIONAL, 1994, 46 (02) : 333 - 340