Evaluation of Blood-Brain Barrier Integrity by the Analysis of Dynamic Contrast-Enhanced MRI - a Comparison of Quantitative and Semi-Quantitative Methods

被引:4
作者
Kala, David [1 ,2 ]
Sulc, Vlastimil [3 ,4 ]
Olserova, Anna [3 ,4 ]
Svoboda, Jan [1 ]
Prysiazhniuk, Yeva [1 ]
Posusta, Antonin [1 ]
Kyncl, Martin [4 ,5 ]
Sanda, Jan [4 ,5 ]
Tomek, Ales [3 ]
Otahal, Jakub [1 ,6 ]
机构
[1] Czech Acad Sci, Inst Physiol, Lab Dev Epileptol, Videnska 1083, Prague 4, Czech Republic
[2] Czech Tech Univ, Fac Elect Engn, Prague, Czech Republic
[3] Charles Univ Prague, Fac Med 2, Dept Neurol, Prague, Czech Republic
[4] Univ Hosp Motol, Prague, Czech Republic
[5] Charles Univ Prague, Fac Med 2, Dept Radiol, Prague, Czech Republic
[6] Charles Univ Prague, Fac Med 2, Dept Pathophysiol, Prague, Czech Republic
关键词
DCE MRI; Time-intensity curve; Blood-brain barrier; Stroke; Toft?s model; DCE-MRI; KINETIC-PARAMETERS; TRACER KINETICS; INPUT FUNCTION; PERMEABILITY; PERFUSION; STROKE; INTENSITY; DIFFUSION;
D O I
10.33549/physiolres.934998
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Disruption of the blood-brain barrier (BBB) is a key feature of various brain disorders. To assess its integrity a parametrization of dynamic magnetic resonance imaging (DCE MRI) with a contrast agent (CA) is broadly used. Parametrization can be done quantitatively or semi-quantitatively. Quantitative methods directly describe BBB permeability but exhibit several drawbacks such as high computation demands, reproducibility issues, or low robustness. Semi-quantitative methods are fast to compute, simply mathematically described, and robust, however, they do not describe the status of BBB directly but only as a variation of CA concentration in measured tissue. Our goal was to elucidate differences between five semi-quantitative parameters: maximal intensity (Imax), normalized permeability index (NPI), and difference in DCE values between three timepoints: baseline, 5 min, and 15 min (Delta 5-0, Delta 15-0, Delta 15-5) and two quantitative parameters: transfer constant (Ktrans) and an extravascular fraction (Ve). For the purpose of comparison, we analyzed DCE data of four patients 12-15 days after the stroke with visible CA enhancement. Calculated parameters showed abnormalities spatially corresponding with the ischemic lesion, however, findings in individual parameters morphometrically differed. Ktransand Ve were highly correlated. Delta 5-0and Delta 15-0 were prominent in regions with rapid CA enhancement and highly correlated with Ktrans. Abnormalities in Delta 15-5and NPIwere more homogenous with less variable values, smoother borders, and less detail than Ktrans. Moreover, only Delta 15-5 and NPI were able to distinguish vessels from extravascular space. Our comparison provides important knowledge for understanding and interpreting parameters derived from DCE MRI by both quantitative and semi-quantitative methods.
引用
收藏
页码:S259 / S275
页数:17
相关论文
共 50 条
  • [1] Reproducibility of dynamic contrast-enhanced MRI in human muscle and tumours: comparison of quantitative and semi-quantitative analysis
    Galbraith, SM
    Lodge, MA
    Taylor, NJ
    Rustin, GJS
    Bentzen, S
    Stirling, JJ
    Padhani, AR
    NMR IN BIOMEDICINE, 2002, 15 (02) : 132 - 142
  • [2] Comparison of semi-quantitative and quantitative dynamic contrast-enhanced MRI evaluations of vertebral marrow perfusion in a rat osteoporosis model
    Zhu, Jingqi
    Xiong, Zuogang
    Zhang, Jiulong
    Qiu, Yuyou
    Hua, Ting
    Tang, Guangyu
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [3] Use of dynamic contrast-enhanced MRI to measure subtle blood-brain barrier abnormalities
    Armitage, Paul A.
    Farrall, Andrew J.
    Carpenter, Trevor K.
    Doubal, Fergus N.
    Wardlaw, Joanna M.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (03) : 305 - 314
  • [4] 7T dynamic contrast-enhanced MRI for the detection of subtle blood-brain barrier leakage
    Canjels, Lisanne P. W.
    Jansen, Jacobus F. A.
    van den Kerkhof, Marieke
    Alers, Robert-Jan
    Poser, Benedikt A.
    Wiggins, Christopher J.
    Schiffer, Veronique M. M. M.
    van de Ven, Vincent
    Rouhl, Rob P. W.
    Palm, W. M.
    van Oostenbrugge, Robert J.
    Aldenkamp, Albert P.
    Ghossein-Doha, Chahinda
    Spaanderman, Marc E. A.
    Backes, Walter H.
    JOURNAL OF NEUROIMAGING, 2021, 31 (05) : 902 - 911
  • [5] Comparison of dynamic contrast-enhanced MRI and quantitative SPECT in a rat glioma model
    Skinner, Jack T.
    Yankeelov, Thomas E.
    Peterson, Todd E.
    Does, Mark D.
    CONTRAST MEDIA & MOLECULAR IMAGING, 2012, 7 (06) : 494 - 500
  • [6] Quantitative Measurement of Blood-Brain Barrier Permeability in Human Using Dynamic Contrast-Enhanced MRI with Fast T1 Mapping
    Taheri, Saeid
    Gasparovic, Charles
    Shah, Nadim Jon
    Rosenberg, Gary A.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1036 - 1042
  • [7] Assessment of Blood-Brain Barrier Permeability by Dynamic Contrast-Enhanced MRI in Transient Middle Cerebral Artery Occlusion Model after Localized Brain Cooling in Rats
    Kim, Eun Soo
    Lee, Seung-Koo
    Kwon, Mi Jung
    Lee, Phil Hye
    Ju, Young-Su
    Yoon, Dae Young
    Kim, Hye Jeong
    Lee, Kwan Seop
    KOREAN JOURNAL OF RADIOLOGY, 2016, 17 (05) : 715 - 724
  • [8] Subtle blood-brain barrier leakage rate and spatial extent: Considerations for dynamic contrast-enhanced MRI
    van de Haar, Harm J.
    Jansen, Jacobus F. A.
    Jeukens, Cecile R. L. P. N.
    Burgmans, Saartje
    van Buchem, Mark A.
    Muller, Majon
    Hofman, Paul A. M.
    Verhey, Frans R. J.
    van Osch, Matthias J. P.
    Backes, Walter H.
    MEDICAL PHYSICS, 2017, 44 (08) : 4112 - 4125
  • [9] Dynamic contrast-enhanced MRI perfusion of normal muscle in adult hips: Variation of permeability and semi-quantitative parameters
    El Rafei, Mazen
    Teixeira, Pedro
    Norberciak, Laurene
    Badr, Sammy
    Cotten, Anne
    Budzik, Jean-Francois
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 108 : 92 - 98
  • [10] Assessment of blood-brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review
    Heye, Anna K.
    Culling, Ross D.
    Valdes Hernandez, Maria del C.
    Thrippleton, Michael J.
    Wardlaw, Joanna M.