Simultaneous analysis of codeine and its active metabolites in human plasma using liquid chromatography-tandem mass spectrometry: Application to a pharmacokinetic study after oral administration of codeine

被引:10
作者
Wu, Xiujun [1 ,2 ]
Zhang, Weiping [3 ]
Bai, Yin [4 ]
Guo, Tao [1 ]
Gu, Jingkai [5 ]
机构
[1] Shenyang Northern Hosp, Dept Pharm, Shenyang 110016, Peoples R China
[2] Liaoning Univ Tradit Chinese Med, Affiliated Hosp, Shenyang 110032, Peoples R China
[3] Shenyang Pharmaceut Univ, Sch Tradit Chinese Mat Med, Shenyang 110016, Peoples R China
[4] Chifeng Univ, Coll Med Sci, Chifeng 024000, Peoples R China
[5] Jilin Univ, Coll Life Sci, Res Ctr Drug Metab, Changchun 130021, Peoples R China
关键词
Codeine; Morphine; 3; beta-glucuronide; 6; LC MS/MS; INTERETHNIC DIFFERENCES; EXTENSIVE METABOLIZERS; GC-MS; MORPHINE; 6-MONOACETYLMORPHINE; 6-GLUCURONIDES; QUANTIFICATION; GLUCURONIDE; OPIATES; BLOOD;
D O I
10.1016/j.jpba.2013.02.027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and sensitive bioassay based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been developed and validated for the simultaneous determination of codeine and its active metabolites, including morphine, morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G), in human plasma. Sample preparation of plasma after the addition of naloxone as internal standard (IS) involved solid-phase extraction (SPE) on C18 cartridges. Reversed-phase chromatography using a gradient elution with methanol and 0.04% formic acid solution (pH 3.5) was used for separation in a run time of 5 min. The analytes were detected in the positive ion mode using multiple reaction monitoring (MRM) of the transitions at m/z 300.4 -> 215.2 for codeine, 286.2 -> 152.0 for morphine, and 462.2 -> 286.2 for M3G and M6G. The method has the following performance characteristics: a reliable response range of 0.05-80 ng/ml for codeine, M3G and M6G and a response range of 0.05-5.0 ng/ml for morphine with correlation coefficients (r) of >0.997 for all analytes. The lower limit of quantitation (LLOQ) for all four analytes was 0.05 ng/ml. The intra- and inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels showed <12% relative standard deviation (RSD) and -6.9 to 8.1% relative error (RE) for all the analytes. The method was successfully applied to a pharmacokinetic study of codeine in healthy Mongolian Chinese volunteers after a 30 mg oral dose. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:261 / 268
页数:8
相关论文
共 21 条
  • [1] [Anonymous], 2001, Guidance for Industry: Bioanalytical Method Validation
  • [2] Myth: codeine is a powerful and effective analgesic
    Arora, S
    Herbert, ME
    [J]. WESTERN JOURNAL OF MEDICINE, 2001, 174 (06) : 428 - 428
  • [3] Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart® opiate microplate EIA and GC-MS following controlled codeine administration
    Barnes, AJ
    Kim, I
    Schepers, R
    Moolchan, ET
    Wilson, L
    Cooper, G
    Reid, C
    Hand, C
    Huestis, MA
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (07) : 402 - 406
  • [4] Determination of morphine and its 3- and 6-glucuronides, codeine, codeine-glucuronide and 6-monoacetylmorphine in body fluids by liquid chromatography atmospheric pressure chemical ionization mass spectrometry
    Bogusz, MJ
    Maier, RD
    Erkens, M
    Driessen, S
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1997, 703 (1-2): : 115 - 127
  • [5] Claudia C.F., 2011, ANAL BIOANAL CHEM, V400, P715
  • [6] Method for quantification of morphine and its 3-and 6-glucuronides, codeine, codeine glucuronide and 6-monoacetylmorphine in human blood by liquid chromatography-electrospray mass spectrometry for routine analysis in forensic toxicology
    Dienes-Nagy, A
    Rivier, L
    Giroud, C
    Augsburger, M
    Mangin, P
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) : 109 - 118
  • [7] Codeine intoxication associated with ultrarapid CYP2D6 metabolism
    Gasche, Y
    Daali, Y
    Fathi, M
    Chiappe, A
    Cottini, S
    Dayer, P
    Desmeules, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (27) : 2827 - 2831
  • [8] Evaluation of a solid-phase extraction procedure for the simultaneous determination of morphine, 6-monoacetylmorphine, codeine and dihydrocodeine in plasma and whole blood by GC/MS
    Geier, A
    Bergemann, D
    vonMeyer, L
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1996, 109 (02) : 80 - 83
  • [9] Pharmacokinetics of codeine and its metabolite morphine in ultra-rapid metabolizers due to CYP2D6 duplication
    Kirchheiner, J.
    Schmidt, H.
    Tzvetkov, M.
    Keulen, J-Tha
    Loetsch, J.
    Roots, I.
    Brockmoeller, J.
    [J]. PHARMACOGENOMICS JOURNAL, 2007, 7 (04) : 257 - 265
  • [10] Rapid simultaneous determination of codeine and morphine in plasma using LIC-ESI-MS/MS: Application to a clinical pharmacokinetic study
    Liao, Qiongfeng
    Deng, Yating
    Xie, Zhiyong
    Pan, Biyan
    Zhang, Lei
    [J]. JOURNAL OF SEPARATION SCIENCE, 2009, 32 (02) : 202 - 211