Use of 3D-Printed Patient Specific Guides in Osteotomies around the Knee

被引:2
作者
Dasari, Suhas P. [1 ,2 ]
Fortier, Luc M. [1 ]
Maheshwer, Bhargavi [1 ]
Hevesi, Mario [1 ]
Gursoy, Safa [1 ]
Chahla, Jorge [1 ]
机构
[1] Rush Univ, Dept Orthopaed Surg, Med Ctr, 1611 W Harrison St,Suite 300, Chicago, IL 60612 USA
[2] Rush Univ, Med Ctr, Chicago, IL USA
关键词
patient specific instrumentation; 3D printing; high tibial osteotomy; distal femoral osteotomy; HIGH TIBIAL OSTEOTOMY; CUTTING GUIDES; LIMB ALIGNMENT; LONG-TERM; SURVIVAL;
D O I
10.1016/j.otsm.2022.150936
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
High tibial osteotomies are challenging procedures that have traditionally implemented two-dimensional planning (2D) for a complex three-dimensional surgery (3D). In an effort to improve the accuracy and precision of the technique, there has been a growing interest in the use of patient specific instrumentation (PSI). The implementation of PSI in osteotomies has demonstrated consistent and reliable results in the correction of the hip-knee-ankle angle, proximal tibial angle, and the posterior tibial slope. Initial clinical studies describing the implementation of this technology have reported superior accuracy in both the corona! and sagittal planes as compared to free-hand techniques. Additionally, these studies reported a fast surgeon learning curve, short operative times, and minimal fluoroscopy exposure. The senior author's preferred closing wedge HTO technique utilizes a patient specific cutting guide with osteotomy fixation provided by an extra-cortical titanium alloy locking plate. This technique is designed to provide reliable and accurate HTOs while minimizing the risk of major complications such as hinge fractures on the contralateral cortex. (C) 2022 Elsevier Inc. All rights reserved.
引用
收藏
页数:9
相关论文
共 27 条
  • [1] The effects of valgus medial opening wedge high tibial osteotomy on articular cartilage pressure of the knee: A biomechanical study
    Agneskirchner, Jens Dominik
    Hurschler, Christof
    Wrann, Christiane D.
    Lobenhoffer, Philipp
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (08) : 852 - 861
  • [2] Three dimensional-printed patient-specific cutting guides for femoral varization osteotomy: Do it yourself
    Arnal-Burro, Juan
    Perez-Mananes, Ruben
    Gallo-del-Valle, Eudaldo
    Igualada-Blazquez, Cristina
    Cuervas-Mons, Manuel
    Vaquero-Martin, Javier
    [J]. KNEE, 2017, 24 (06) : 1359 - 1368
  • [3] Patient-specific cutting guides for open-wedge high tibial osteotomy: safety and accuracy analysis of a hundred patients continuous cohort
    Chaouche, Samir
    Jacquet, Christophe
    Fabre-Aubrespy, Maxime
    Sharma, Akash
    Argenson, Jean-Noel
    Parratte, Sebastien
    Ollivier, Matthieu
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (12) : 2757 - 2765
  • [4] PROXIMAL TIBIAL OSTEOTOMY - A CRITICAL LONG-TERM STUDY OF 87 CASES
    COVENTRY, MB
    ILSTRUP, DM
    WALLRICHS, SL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) : 196 - 201
  • [5] Delp SL, 1998, CLIN ORTHOP RELAT R, P49
  • [6] Adding a protective K-wire during opening high tibial osteotomy increases lateral hinge resistance to fracture
    Dessyn, Edouard
    Sharma, Akash
    Donnez, Mathias
    Chabrand, Patrick
    Ehlinger, Matthieu
    Argenson, Jean-Noel
    Parratte, Sebastien
    Ollivier, Matthieu
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (03) : 751 - 758
  • [7] Are three-dimensional patient-specific cutting guides for open wedge high tibial osteotomy accurate? An in vitro study
    Donnez, Mathias
    Ollivier, Matthieu
    Munier, Maxime
    Berton, Philippe
    Podgorski, Jean-Pierre
    Chabrand, Patrick
    Parratte, Sebastien
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
  • [8] Accuracy of 3D-planned patient specific instrumentation in high tibial open wedge valgisation osteotomy
    Fucentese, Sandro F.
    Meier, Patrick
    Jud, Lukas
    Kochli, Gian-Luca
    Aichmair, Alexander
    Vlachopoulos, Lazaros
    Furnstahl, Philipp
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2020, 7 (01)
  • [9] Advances in modern osteotomies around the knee Report on the Association of Sports Traumatology, Arthroscopy, Orthopaedic surgery, Rehabilitation (ASTAOR) Moscow International Osteotomy Congress 2017
    Gao, Liang
    Madry, Henning
    Chugaev, Dmitrii V.
    Denti, Matteo
    Frolov, Aleksandr
    Burtsev, Mikhail
    Magnitskaya, Nina
    Mukhanov, Victor
    Neyret, Philippe
    Solomin, Leonid N.
    Sorokin, Evgeniy
    Staubli, Alex E.
    Stone, Kevin R.
    Vilenskiy, Viktor
    Zayats, Vitaliy
    Pape, Dietrich
    Korolev, Andrey
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2019, 6 (01)
  • [10] Survival and clinical outcome of isolated high tibial osteotomy and combined biological knee reconstruction
    Harris, Joshua D.
    McNeilan, Ryan
    Siston, Robert A.
    Flanigan, David C.
    [J]. KNEE, 2013, 20 (03) : 154 - 161