Prospective Clinical Trial Evaluating a New Implant System for Implant Survival, Implant Stability and Radiographic Bone Changes

被引:18
作者
Becker, William [1 ,2 ]
Becker, Burton E.
Hujoel, Philippe [3 ]
Abu Ras, Zakaria [4 ]
Goldstein, Moshe [5 ]
Smidt, Ami [4 ]
机构
[1] Univ So Calif, Sch Dent, Dept Grad Periodont, Tucson, AZ 85711 USA
[2] Univ Washington, Dept Grad Periodont, Seattle, WA 98195 USA
[3] Univ Washington, Dept Dent Publ Hlth Sci, Seattle, WA 98195 USA
[4] Hebrew Univ Jerusalem Hadassah Hosp & Med Sch, Ctr Grad Studies Prosthodont, Jerusalem, Israel
[5] Hadassah Hebrew Univ, Med Ctr, Fac Med Dent, Jerusalem, Israel
关键词
implant survival; prospective; RFA; X-ray measurements; RESONANCE FREQUENCY MEASUREMENTS; TITANIUM IMPLANTS; AUGMENTATION; EXTRACTION; PLACEMENT; BRANEMARK;
D O I
10.1111/j.1708-8208.2010.00333.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: There are a few prospective studies reporting on new implant systems. When a new implant is brought to market, prospective trials should be carried out to determine the predictability of that system. Purpose: This prospective study evaluates implant survival, Resonance Frequency Analysis (RFA), and crestal bone level changes for a new implant system (Neoss System, Bimodal surface, Neoss Ltd, Harrogate, UK). Materials and Methods: Seventy-six patients, 38 females (age ranging from 23 to 57 years) and 38 males (ranging in age from 17 to 85 years) received 100 Neoss implants. Patients were consecutively enrolled in the study if they were missing one or more teeth in either arch, or a single tooth was scheduled for removal and immediate implant replacement. Evaluated implants were 4, 4.5, or 5 mm wide and were 7, 9, 11, 13, or 15 mm long. A one-stage approach was followed. At first stage and prior to healing abutment placement RFA measurements were taken. Measurements were retaken at second stage. Fifty-one implants were placed for restoration of single missing teeth and 49 were for short span implant bridges. Results: The cumulative survival rate at 1- to 2-year interval was 93%. Average initial RFA measurement for all implants was 72.06, while the average final score was 72.58. These changes were not statistically significant. Changes in RFA scores for maxillary implants were insignificant. Forty-two paired mandibular RFA measurements were evaluated. Initial and final mean mandibular RAF measurements were 73.65 (SD 9.203) and 77.186 (SD 6.177), respectively. These changes were statistically significant (p = .02). Sixty-four paired radiographs were available for evaluation. Between examinations, there was an average 0.6 mm of bone loss, which was statistically significant (p = .03). On average, 4.0-mm-wide implants lost 0.1 mm of bone when compared with 5-mm-wide implants. These differences were insignificant (p = .86). Bone loss was adjusted for implant length, and tooth position and there were small, but clinically insignificant changes. Five-millimeter-wide implants lose 0.2 mm more than 4.0-mm-wide implants (p = .7). Maxillary incisors lose the least amount of bone 0.152 (p = .33). Conclusions: The implants tested in this study had initially high RAF readings, indicating good primary stability. RFA readings for implants placed in the mandible improved from baseline and the changes were statistically significant. Marginal bone levels revealed clinically insignificant bone loss from implant installation to second stage. Loss of seven implants with initially high RFA readings is surprising.
引用
收藏
页码:15 / 21
页数:7
相关论文
共 32 条
  • [1] Implant stability in relation to osseointegration: an experimental study in the Labrador dog
    Abrahamsson, Ingemar
    Linder, Elena
    Lang, Niklaus P.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) : 313 - 318
  • [2] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [3] ADELL R, 1990, International Journal of Oral and Maxillofacial Implants, V5, P347
  • [4] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [5] [Anonymous], 1998, COMPEND CONTIN ED DE
  • [6] Astrand Per, 2004, Clin Implant Dent Relat Res, V6, P130, DOI 10.1111/j.1708-8208.2004.tb00213.x
  • [7] Balleri Piero, 2002, Clin Implant Dent Relat Res, V4, P128, DOI 10.1111/j.1708-8208.2002.tb00162.x
  • [8] Implant stability measurements for implants placed at the time of extraction: A cohort, prospective clinical trial
    Becker, W
    Sennerby, L
    Bedrossian, E
    Becker, BE
    Lucchini, JP
    [J]. JOURNAL OF PERIODONTOLOGY, 2005, 76 (03) : 391 - 397
  • [9] Becker W, 1997, INT J ORAL MAX IMPL, V12, P454
  • [10] Histomorphometric evaluation of human sinus floor augmentation healing responses to placement of calcium phosphate or Ricinus communis polymer associated with autogenous bone
    Boëck-Neto, RJ
    Gabrielli, MFR
    Shibli, JA
    Marcantonio, E
    Lia, RCC
    Marcantonio, E
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 (04) : 181 - 188