Comparison of Surgical Outcomes of Large Orbital Fractures Reconstructed With Porous Polyethylene Channel and Porous Polyethylene Titan Barrier Implants

被引:18
作者
Kim, Chang Yeom [1 ]
Jeong, Byung Jin [2 ]
Lee, Sang Yeul [1 ]
Yoon, Jin Sook [1 ]
机构
[1] Yonsei Univ, Coll Med, Inst Vis Res, Dept Ophthalmol, Seoul 120752, South Korea
[2] Cheil Eye Hosp, Div Oculoplasty, Taegu, South Korea
关键词
MEDPOR; SURGERY;
D O I
10.1097/IOP.0b013e3182467c4a
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the postoperative outcomes of large orbital fractures repaired with porous polyethylene (PP) channel implants (PPCIs) and PP titan barrier implants (PPTBs). Methods: Medical records of 42 patients who underwent surgical reconstruction for a large orbital fracture with either PPCI or PPTB were reviewed retrospectively. The degree of diplopia, determined with a binocular single vision test, and enophthalmos, measured by a Hertel exophthalmometer, was compared between 2 implant groups. Orbital volumes were calculated using CT scans and the measuring tool. Results: Of the 42 patients examined, 16 received PPCI and 26 received PPTB. No significant difference in the degree of diplopia was observed between the 2 implant groups before surgery, and 1 and 3 months after surgery (p = 0.256, 0.408, and 0.432, respectively). Preoperative average enophthalmos measuring 1.28 mm and 1.04 mm was successfully corrected to 0.19 mm and 0.25 mm 3 months after reconstruction with PPCI and PPTB, respectively. The fractured orbit volumes and nonfractured contralateral orbit volumes were 24.96 +/- 2.32 cm(3) and 23.18 +/- 1.73 cm(3) in the PPCI group, and 26.80 +/- 2.10 cm(3) and 24.13 +/- 2.28 cm(3) in the PPTB group, respectively. After surgery, the fractured orbit volumes significantly decreased to 23.39 +/- 2.82 cm(3) in the PPCI group and to 23.53 +/- 1.74 cm(3) in the PPTB group; these values were not significantly different from that of the nonfractured orbit (p = 0.681 for PPCI and 0.204 for PPTB). Conclusions: Porous polyethylene channel implant and PPTB are both effective implant materials for the repair of large orbital fractures; however, PPTB has the additional benefit of not requiring screw fixation. (Ophthal Plast Reconstr Surg 2012;28:176-180)
引用
收藏
页码:176 / 180
页数:5
相关论文
共 14 条
  • [1] Outcomes of orbital blowout fracture surgery in children and adolescents
    Carroll, Stuart C.
    Ng, Stephen G. J.
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (06) : 736 - 739
  • [2] Porous polyethylene channel implants: A modified porous polyethylene sheet implant designed for repairs of large and complex orbital wall fractures
    Choi, JC
    Fleming, JC
    Aitken, PA
    Shore, JW
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (01) : 56 - 66
  • [3] Long-term sequelae after surgery for orbital floor fractures
    Folkestad, L
    Westin, T
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 120 (06) : 914 - 921
  • [4] Use of porous polyethylene with embedded titanium in orbital reconstruction: A review of 106 patients
    Garibaldi, Daniel C.
    Nicholas, T. Iliff
    Grant, Michael P.
    Merbs, Shannath L.
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2007, 23 (06) : 439 - 444
  • [5] Safety of titanium mesh for orbital reconstruction
    Gear, AJL
    Lokeh, A
    Aldridge, JH
    Migliori, MR
    Benjamin, CI
    Schubert, W
    [J]. ANNALS OF PLASTIC SURGERY, 2002, 48 (01) : 1 - 7
  • [6] ANIMAL-MODEL OF POROUS POLYETHYLENE ORBITAL IMPLANTS
    GOLDBERG, RA
    DRESNER, SC
    BRASLOW, RA
    KOSSOVSKY, N
    LEGMANN, A
    [J]. OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 10 (02) : 104 - 109
  • [7] KARESH JW, 1994, OPHTHALMOLOGY, V101, P1688
  • [8] MAAS CS, 1990, ARCH OTOLARYNGOL, V116, P551
  • [9] Analysis of the postoperative outcome in 405 cases of orbital fracture using 2 synthetic orbital implants
    Nam, SB
    Bae, YC
    Moon, JS
    Kang, YS
    [J]. ANNALS OF PLASTIC SURGERY, 2006, 56 (03) : 263 - 267
  • [10] Medpor porous polyethylene implants in orbital blowout fracture repair
    Ng, SGJ
    Madill, SA
    Inkster, CF
    Maloof, AJ
    Leatherbarrow, B
    [J]. EYE, 2001, 15 (5) : 578 - 582