Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [31] What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?
    Lu, Jin-guo
    Lv, Bin
    Chen, Xiong-biao
    Tang, Xiang
    Jiang, Shi-liang
    Dai, Ru-ping
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : 159 - 165
  • [32] Quantitative assessment of left ventricular systolic wall thickening using multidetector computed tomography
    Kristensen, Thomas S.
    Kofoed, Klaus F.
    Moller, Daniel V.
    Ersboll, Mads
    Kuhl, Tobias
    von der Recke, Peter
    Kober, Lars
    Nielsen, Michael B.
    Kelbaek, Henning
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (01) : 92 - 97
  • [33] Role of multi-detector computed tomography in the evaluation of pancreatic tumors
    Dawoud, Mahmoud Abdelaziz
    Youssef, Mohamed Ahmed
    Elbarbary, Aly Aly
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (02) : 309 - 316
  • [34] Multi-detector computed tomography imaging of blunt chest trauma
    Dabees, Naglaa L.
    Salama, Alsiagy A.
    Elhamid, Samar Abd
    Sabry, Mohab M.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (04) : 1105 - 1113
  • [35] Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography
    Heuschmid, M
    Rothfuss, JK
    Schroeder, S
    Fenchel, M
    Stauder, N
    Burgstahler, C
    Franow, A
    Kuzo, RS
    Kuettner, A
    Miller, S
    Claussen, CD
    Kopp, AF
    EUROPEAN RADIOLOGY, 2006, 16 (03) : 551 - 559
  • [36] Left ventricular remodelling and systolic function measurement with 64 multi-slice computed tomography versus second harmonic echocardiography in patients with coronary artery disease: A double blind study
    Palazzuoli, Alberto
    Cademartiri, Filippo
    Geleijnse, Marcel L.
    Meijboom, Bob
    Pugliese, Francesca
    Soliman, Osama
    Calabro, Anna
    Nuti, Ranuccio
    de Feyter, Pirn
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (01) : 82 - 88
  • [37] Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography
    Martin Heuschmid
    Julia K. Rothfuss
    Stephen Schroeder
    Michael Fenchel
    Norbert Stauder
    Christof Burgstahler
    Andreas Franow
    Ronald S. Kuzo
    Axel Kuettner
    Stephan Miller
    Claus D. Claussen
    Andreas F. Kopp
    European Radiology, 2006, 16 : 551 - 559
  • [38] Traumatic Lens Dislocation: Multi-Detector Computed Tomography Findings
    Kurtcan, Serpil
    Yalcin, Ahmet
    Kantarci, Mecit
    EURASIAN JOURNAL OF MEDICINE, 2007, 39 (03) : 227 - 228
  • [39] Mechanical mitral valve thrombosis and giant left atrial thrombus: Comparison of transesophageal echocardiography and 64-slice multidetector computed tomography
    Gunduz, Sabahattin
    Ozkan, Mehmet
    Biteker, Murat
    Guneysu, Tahsin
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2009, 37 (07): : 483 - 487
  • [40] Left Atrial Volume by Real-Time Three-Dimensional Echocardiography: Validation by 64-Slice Multidetector Computed Tomography
    Miyasaka, Yoko
    Tsujimoto, Satoshi
    Maeba, Hirofumi
    Yuasa, Fumio
    Takehana, Kazuya
    Dote, Kinuko
    Iwasaka, Toshiji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) : 680 - 686