Assessment of left ventricular function with 16-and 64-slice multi-detector computed tomography

被引:22
|
作者
Abbara, Suhny [1 ,2 ]
Chow, Benjamin J. W. [1 ,2 ,3 ]
Pena, Antonio J. [1 ,2 ]
Cury, Ricardo C. [1 ,2 ]
Hoffmann, Udo [1 ,2 ]
Nieman, Koen [1 ,2 ]
Brady, Thomas J. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
[3] Univ Ottawa, Inst Heart, Div Cardiol, Ottawa, ON K1N 6N5, Canada
关键词
left ventricular function; MDCT; echocardiography; SPECT; semi-automated MDCT data analysis;
D O I
10.1016/j.ejrad.2007.07.022
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Important to the risk stratification and management of cardiac patients is the assessment of left ventricular function (LVEF), thus imaging modalities which can provide both anatomical and functional data is desirable. Electrocardiographic (ECG) gated multi-detector computed tomographic (MDCT) images may provide accurate assessment of LV ejection fraction, volume and dimensions but have shown systemic errors in the past due to slow gantry rotation speed. Methods: Between May 2004 and January 2005, 306 patients underwent ECG-gated cardiac CT studies at the Massachusetts General Hospital. Patients with available CT data sets and a recent (within 3 months) ECHO and/or SPECT perfusion imaging were included in the study. ECG-gated data sets were acquired either with a 16-slice or with a 64-slice MDCT. Functional MDCT data sets were reconstructed in 10 cardiac phases (5-95%) with 1.5 mm slices. Images were processed and interpreted by two observers blinded to ECHO and SPECT results. Results: A total of 69 patients had MDCT and ECHO or SPECT within 3 months (33 had 16-slice and 36 had 64-slice MDCT). There was fair correlation between LVEF measured by 16-slice MDCT and 'ECHO or SPECT' (62 +/- 10% vs. 62 +/- 10%; r = 0.56). There was poor correlation between LVEF measured by 16-slice MDCT and ECHO (64 +/- 10% vs. 59 +/- 11%; r = 0.26) and there was good correlation between LVEF measured by 16-slice MDCT and SPECT (62 +/- 11% and 64 +/- 9%, respectively; r = 0.76). There was very good correlation between LVEF measured by 64-slice MDCT and 'ECHO or SPECT' (57 +/- 15% vs. 58 +/- 13%; r = 0.86). There was very good correlation between LVEF measured by MDCT and ECHO (56 +/- 14% vs. 54 +/- 15%; r = 0.89) and between LVEF measured by 64-slice MDCT and SPECT (60 13% and 60 14%, respectively; r = 0.90). Conclusion: The assessment of LVEF and LV dimensions with 64-slice MDCT provide values which are similar to those obtained by echocardiography and Tc-99m gated SPECT. The accuracy of the 64-slice MDCT with a gantry rotation speed of 330 ms (when compared to ECHO and SPECT) may be superior to that of the 16-slice MDCT at 420 ms gantry rotation. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [21] Accuracy of nonstenotic coronary atherosclerosis assessment by multi-detector computed tomography
    Hara, Tetsuya
    Yamada, Shinichiro
    Hayashi, Takatoshi
    Ikeda, Yoshihiro
    Yamashiro, Kohei
    Mizutani, Kazuo
    Iwata, Sachiyo
    Okajima, Katsunori
    Tsukishiro, Yasue
    Matsumoto, Kensuke
    Akagami, Takafumi
    Kumagai, Hiroyuki
    Kinugasa, Mitsuo
    Inoue, Michihiko
    Murai, Naoki
    Izawa, Ichiro
    Kajiya, Teishi
    CIRCULATION JOURNAL, 2007, 71 (06) : 911 - 914
  • [22] Detection of Aortic Regurgitation with 64-slice Multidetector Computed Tomography (MDCT)
    Zeb, Irfan
    Hamirani, Yasmin S.
    Mao, Songshuo
    Isma'eel, Hussain
    Saeed, Anila
    Karnwal, Sudha
    Raina, Sameer
    Chung, Jina
    Budoff, Matthew J.
    ACADEMIC RADIOLOGY, 2010, 17 (08) : 1006 - 1011
  • [23] MULTI-DETECTOR COMPUTED TOMOGRAPHY IN ABDOMINAL TUBERCULOSIS
    Omprakash, A. R.
    D'Souza, Reshmina C.
    Sudarshan, Sunil H.
    Yadav, Vishwanath
    Aithala, P. S.
    Pai, Ramakrishna J.
    Fernandes, Aaron Marion
    Kaneria, Tessa Jose
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (03): : 565 - 568
  • [24] Assessment of left ventricular volumes and ejection fraction with 16-slice multi-slice computed tomography; comparison with 2D-echocardiography
    Schuijf, J. D.
    Bax, J. J.
    Jukema, J. W.
    Lamb, H. J.
    Salm, L. P.
    de Roos, A.
    van der Wall, E. E.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2007, 116 (02) : 201 - 205
  • [25] Evaluation of pulmonary vein variations and anomalies with 64 slice multi detector computed tomography
    Tekbas, Guven
    Gumus, Hatice
    Onder, Hakan
    Ekici, Faysal
    Hamidi, Cihad
    Tekbas, Ebru
    Gulicetincakmak, Mehmet
    Yavuz, Celal
    Bilici, Aslan
    WIENER KLINISCHE WOCHENSCHRIFT, 2012, 124 (1-2) : 3 - 10
  • [26] Computer-Aided Detection of Acute Pulmonary Embolism With 64-Slice Multi-Detector Row Computed Tomography: Impact of the Scanning Conditions and Overall Image Quality in the Detection of Peripheral Clots
    Dewailly, Marion
    Remy-Jardin, Martine
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Pontana, Fraacois
    Deken, Valerie
    Bakai, Anne-Marie
    Remy, Jacques
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (01) : 23 - 30
  • [27] Clinical contributions of 64-slice computed tomography in the evaluation of cardiomyopathy of unknown origin
    Boulmier, Dominique
    Audinet, Caroline
    Heautot, Jean-Francois
    Larralde, Antoine
    Veillard, David
    Hamonic, Stephanie
    Bedossa, Marc
    Leurent, Guillaume
    Garreau, Mireille
    Le Breton, Herve
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (10) : 685 - 696
  • [28] Multi-detector computed tomography of an aortic dissection in a cat
    Scollan, Katherine
    Sisson, David
    JOURNAL OF VETERINARY CARDIOLOGY, 2014, 16 (01) : 67 - 72
  • [29] Influence of left ventricular geometry and function on aortic annular dimensions as assessed with multi-detector row computed tomography: implications for transcatheter aortic valve implantation
    Ng, Arnold C. T.
    Yiu, Kai-Hang
    Ewe, See Hooi
    van der Kley, Frank
    Bertini, Matteo
    de Weger, Arend
    de Roos, Albert
    Leung, Dominic Y.
    Schuijf, Joanne D.
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    EUROPEAN HEART JOURNAL, 2011, 32 (22) : 2806 - 2813
  • [30] 64-slice multidetector computed tomography (MDCT) for detection of aortic regurgitation and quantification of severity
    Jassal, Davinder S.
    Shapiro, Michael D.
    Neilan, Tomas G.
    Chaithiraphan, Vithaya
    Ferencik, Maros
    Teague, Shawn D.
    Brady, Thomas J.
    Isselbacher, Eric M.
    Cury, Ricardo C.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (07) : 507 - 512