Microtensile bond strength of current dentin adhesives measured immediately and 24 hours after application

被引:0
作者
Sadek, FT
Goracci, C
Cardoso, PEC
Tay, FR
Ferrari, M
机构
[1] Univ Sao Paulo, Dept Dent Mat, Sao Paulo, Brazil
[2] Univ Siena, Dept Dent Mat, I-53100 Siena, Italy
[3] Univ Sao Paulo, Sao Paulo, Brazil
[4] Univ Hong Kong, Hong Kong, Hong Kong, Peoples R China
关键词
microtensile bond strength; dentin; adhesive system; test period;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the immediate microtensile bond strengths achieved with representative adhesive systems from each of the four current bonding approaches. Materials and Methods: Resin composite was bonded incrementally to flat, midcoronal dentin from 33 human molars, using the adhesives (Adper Scotchbond MP; Adper Scotchbond 1; Optibond Solo Plus; Clearfil SE Bond; AdheSE; Tyrian SPE + One Step Plus; Optibond Solo Plus self-etching; One-Up Bond F; iBond; Adper Prompt L-Pop; Xeno III) according to the respective manufacturer's instructions. The bonded specimens were immediately sectioned into sticks and underwent microtensile bond testing either immediately or after 24 h. Data were analyzed with two-way ANOVA and LSD tests. Results: No significant differences were found between immediate and 24-h bond strengths (p > 0.05). However, significant differences were observed among adhesives (p = 0.001). The all-in-one adhesive iBond showed statistically lower values when compared to all the other adhesives. Adper Prompt L-Pop, Xeno III, Tyrian SPE + One Step Plus and One-Up Bond F, all self-etching adhesives, were significantly weaker than AdheSE, Optibond Solo Plus, Adper Scotchbond 1, Optibond Solo Plus self-etching, Clearfil SE Bond, and Adper Scotchbond MP, which did not differ statistically from each other. Conclusion: Microtensile bond strengths of representative adhesive systems from the four categories of bonding agents were not equivalent, with the lowest values recorded for the one-step self-etching adhesives. There were no differences in the bond strengths when measured immediately and after 24 h.
引用
收藏
页码:297 / 302
页数:6
相关论文
共 34 条
  • [1] Armstrong SR, 2003, J ADHES DENT, V5, P47
  • [2] Asmussen E, 2003, J ADHES DENT, V5, P41
  • [3] A three-dimensional finite element model of the polymerization process in dental restorations
    Barink, M
    Van der Mark, PCP
    Fennis, WMM
    Kuijs, RH
    Kreulen, CM
    Verdonschot, N
    [J]. BIOMATERIALS, 2003, 24 (08) : 1427 - 1435
  • [4] Brackett WW, 2002, OPER DENT, V27, P218
  • [5] EARLY TENSILE BOND STRENGTHS OF SEVERAL ENAMEL AND DENTIN BONDING SYSTEMS
    BURROW, MF
    TAGAMI, J
    NEGISHI, T
    NIKAIDO, T
    HOSODA, H
    [J]. JOURNAL OF DENTAL RESEARCH, 1994, 73 (02) : 522 - 528
  • [6] Callister Jr W. D., 2013, MAT SCI ENG INTRO
  • [7] Cardoso Paulo Eduardo Capel, 2002, J Adhes Dent, V4, P291
  • [8] Carvalho RM, 2004, J ADHES DENT, V6, P13
  • [9] Preventing postoperative tooth sensitivity in Class I, II and V restorations
    Christensen, GJ
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2002, 133 (02) : 229 - 231
  • [10] Evaluation of the fatigue behavior of the resin-dentin bond with the use of different methods
    Frankenberger, R
    Strobel, WO
    Krämer, N
    Lohbauer, U
    Winterscheidt, J
    Winterscheidt, B
    Petschelt, A
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2003, 67B (02) : 712 - 721