Influence of Implant Design and Under-Preparation of the Implant Site on Implant Primary Stability. An In Vitro Study

被引:24
|
作者
Herrero-Climent, Mariano [1 ]
Lemos, Bernardo Ferreira [1 ,2 ]
Herrero-Climent, Federico [3 ]
Falcao, Carlos [1 ,2 ]
Oliveira, Helder [2 ]
Herrera, Manuela [4 ]
Javier Gil, Francisco [5 ]
Rios-Carrasco, Blanca [6 ]
Rios-Santos, Jose-Vicente [6 ]
机构
[1] Porto Dent Inst, P-4150518 Porto, Portugal
[2] Fernando Pessoa Univ, Fac Hlth Sci, P-4249004 Porto, Portugal
[3] Univ Complutense Madrid, Dept Periodontol, Madrid 28040, Spain
[4] Univ Seville, Dept Stomatol, Seville 41009, Spain
[5] Univ Int Catalunya, Fac Dent, Barcelona 08017, Spain
[6] Univ Seville, Dept Periodontol, Seville 41009, Spain
关键词
dental implant; tapered; under-preparation; implant preparation; implant stability; insertion torque; ISQ; RFA; RESONANCE FREQUENCY-ANALYSIS; LOW-DENSITY BONE; DENTAL IMPLANTS; SURGICAL TECHNIQUE; SURFACE-ROUGHNESS; STEPPED OSTEOTOMY; INSERTION TORQUE; HUMAN CADAVERS; OSSEOINTEGRATION; RELIABILITY;
D O I
10.3390/ijerph17124436
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this study was to evaluate the effects of different implant sites an under-preparation sequence associated with two different implant designs on implant primary stability measured by two parameters: insertion torque (IT) and implant stability quotient (ISQ). It used two different implants: one cylindrical as a control and another one with a tapered design. The implants were inserted in type III fresh humid bovine bone and four drilling sequences were used: one control, the one proposed by the implant company (P1), and three different undersized (P2, P3 and P4). P2 was the same as P1 without the cortical drill, P3 was without the last pilot drill and P4 was without both of them. The sample size wasn= 40 for each of the eight groups. Final IT was measured with a torquemeter and the ISQ was measured with Penguin resonance frequency analysis. Results showed that both ISQ and IT have a tendency to increase as the preparation technique reduces the implant site diameter when compared with the standard preparation, P1. The preparations without cortical drill, P2 and P4, showed the best results when compared with the ones with a cortical drill. Tapered implants always showed higher or the same ISQ and IT values when compared with the cylindrical implants. Giving the limitations of this study, it can be concluded that reducing implant preparation can increase IT and ISQ values. Removing the cortical drill and the use of a tapered design implant are also effective methods of increasing primary implant stability.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [21] The Evaluation of the Reliability of Periotest for Implant Stability Measurements: An In Vitro Study
    Bilhan, Hakan
    Cilingir, Altug
    Bural, Canan
    Bilmenoglu, Caglar
    Sakar, Olcay
    Geckili, Onur
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (04) : E90 - E95
  • [22] Comparison of Osteotome and Conventional Drilling Techniques for Primary Implant Stability: An In Vitro Study
    Tsolaki, Ioanna N.
    Tonsekar, Pallavi P.
    Najafi, Babak
    Drew, Howard J.
    Sullivan, Andrew J.
    Petrov, Sofia D.
    JOURNAL OF ORAL IMPLANTOLOGY, 2016, 42 (04) : 321 - 326
  • [23] Ultrasonic implant site preparation vs. conventional drilling: in-vitro evaluation of implant site diameter
    Lahoud, Pierre
    Nasr, Joseph Abi
    Menhall, Abdallah
    Rebaudi, Alberto
    Makary, Christian
    CHIRURGIA-ITALY, 2023, 37 (04): : 224 - 231
  • [24] Effect of implant macro-design on primary stability: A prospective clinical study
    Lozano-Carrascal, Naroa
    Salomo-Coll, Oscar
    Gilabert-Cerda, Marta
    Farre-Pages, Nuria
    Gargallo-Albiol, Jordi
    Hernandez-Alfaro, Federico
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2016, 21 (02): : E214 - E221
  • [25] Primary stability and osseointegration comparing a novel tapered design tissue-level implant with a parallel design tissue-level implant. An experimental in vivo study
    Gill, Thomas
    Kuhl, Sebastian
    Rawlinson, Simon
    Pippenger, Benjamin
    Bellon, Benjamin
    Shahdad, Shakeel
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1114 - 1127
  • [26] Does implant design affect primary stability in extraction sites?
    Karl, Matthias
    Irastorza-Landa, Ainara
    QUINTESSENCE INTERNATIONAL, 2017, 48 (03): : 219 - 224
  • [27] Analyzing the Influence of a New Dental Implant Design on Primary Stability
    da Costa Valente, Mariana Lima
    de Castro, Denise Tornavoi
    Shimano, Antonio Carlos
    Lepri, Cesar Penazzo
    dos Reis, Andrea Candido
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 168 - 173
  • [28] The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs
    Di Stefano, Danilo Alessio
    Perrotti, Vittoria
    Greco, Gian Battista
    Cappucci, Claudia
    Arosio, Paolo
    Piattelli, Adriano
    Iezzi, Giovanna
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (03) : 227 - 235
  • [29] Compensating for poor primary implant stability in different bone densities by varying implant geometry: a laboratory study
    Moehlhenrich, S. C.
    Heussen, N.
    Elvers, D.
    Steiner, T.
    Hoelzle, F.
    Modabber, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (12) : 1514 - 1520
  • [30] Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks
    Orlando, Francesco
    Arosio, Federico
    Arosio, Paolo
    Di Stefano, Danilo Alessio
    DENTISTRY JOURNAL, 2019, 7 (03)