Calcified vascular plaque specimens: Assessment with cardiac dual-energy multidetector CT in anthropomorphically moving heart phantom

被引:71
作者
Boll, Daniel T. [1 ]
Merkle, Elmar M. [1 ]
Paulson, Erik K. [1 ]
Mirza, Rizvan A. [1 ]
Fleiter, Thorsten R. [2 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Durham, NC 27710 USA
[2] Univ Maryland, Med Ctr, Dept Radiol, Baltimore, MD 21201 USA
关键词
D O I
10.1148/radiol.2483071576
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate whether dual-energy multidetector computed tomography (CT) with image postprocessing techniques enhances accuracy of calcified plaque quantification beyond the scope of single-energy multidetector CT, by using optical coherence tomography (OCT) as the reference standard. Materials and Methods: Four atherosclerotic specimens were examined with 64-section dual-energy multidetector CT by using a novel dual-detector "double-decker" design, with stacked high-and low-energy detector arrays with 32 x 0.625-mm collimation, at 140 kVp and 400 mAs, acquiring simultaneous and isopedic low- and high-energy data sets. Additionally, combined-energy data sets were calculated, and an enhancement algorithm was proposed. Cardiac motion was simulated by an anthropomorphically moving phantom, and OCT was used as a reference standard for plaque quantification. Univariate general linear model (GLM) analysis was used to compare sizes of plaque calcifications determined with OCT with those determined with dual-energy multidetector CT, and the significance of factors such as cardiac motion was assessed. Results: GLM analysis revealed that plaque quantification based on low-, high-, and combined-energy data sets differed significantly from that based on OCT (P < .001). Greater data variation occurred in smaller (<8 mm(2)) and larger (>12 mm(2)) calcifications. Comparison of calcified plaque sizes determined with OCT with those determined with the dual-energy multidetector CT enhancement algorithm revealed no significant difference (P = .550). Cardiac activity led to a slight increase in data variation in regard to OCT for corresponding static (mean, 10.2% +/- 3.2 [standard deviation]) and dynamic (13.8% +/- 4.9) dual-energy multidetector CT data sets. Conclusion: Dual-energy multidetector CT with novel postprocessing techniques enhanced accuracy of calcified plaque quantification by reducing effects of tissue blooming and beam hardening beyond single-energy multidetector CT. (C) RSNA, 2008.
引用
收藏
页码:119 / 126
页数:8
相关论文
共 25 条
[1]  
Abramoff MD., 2004, Biophot. Int., V11, P36
[2]   Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom [J].
Begemann, Philipp G. C. ;
van Stevendaal, Udo ;
Koester, Ralph ;
Mahnken, Andreas H. ;
Koops, Andreas ;
Adam, Gerhard ;
Grass, Michael ;
Nolte-Ernsting, Claus .
EUROPEAN RADIOLOGY, 2007, 17 (08) :1985-1994
[3]   Spectral coronary multidetector computed tomography angiography: Dual benefit by facilitating plaque characterization and enhancing lumen depiction [J].
Boll, Daniel T. ;
Hoffmann, Martin H. ;
Huber, Nadine ;
Bossert, Andrea S. ;
Aschoff, Andrik J. ;
Fleiter, Thorsten R. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (05) :804-811
[4]   Coronary risk factors and plaque morphology in men with coronary disease who died suddenly [J].
Burke, AP ;
Farb, A ;
Malcom, GT ;
Liang, YH ;
Smialek, J ;
Virmani, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (18) :1276-1282
[5]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[6]  
Carmi R, 2005, IEEE NUCL SCI CONF R, P1876
[7]   Optical coherence tomography and its use in detection of vulnerable plaque [J].
Cilingiroglu M. ;
Ozer K. .
Current Atherosclerosis Reports, 2006, 8 (2) :140-143
[8]   Detection of vulnerable plaque in a murine model of atherosclerosis with optical coherence tomography [J].
Cilingiroglu, Mehmet ;
Oh, Jung Hwan ;
Sugunan, Binu ;
Kemp, Nate J. ;
Kim, Jeehyun ;
Lee, Shuko ;
Zaatari, Haitham N. ;
Escobedo, Daniel ;
Thomsen, Sharon ;
Milner, Thomas E. ;
Feldman, Marc D. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 67 (06) :915-923
[9]   Direct quantitative in vivo comparison of calcified atherosclerotic plaque on vascular MRI and CT by multimodality image registration [J].
Dey, D ;
Slomka, P ;
Chien, D ;
Fieno, D ;
Abidov, A ;
Saouaf, R ;
Thomson, L ;
Friedman, JD ;
Berman, DS .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (03) :345-354
[10]   Intercomparison of methods for image quality characterization. II. Noise power spectrum [J].
Dobbins, James T., III ;
Samei, Ehsan ;
T Ranger, Nicole ;
Chen, Ying .
MEDICAL PHYSICS, 2006, 33 (05) :1466-1475